10. Touch panel characteristics
Note) For use of finger input
11. Handling of modules
11-1. Inserting the FPC into its connector and pulling it out
11-2. About handling of FPC
11-3. Mounting of the module
1) Be sure to turn off the power supply and the signals when inserting or disconnecting the cable.
2) Please insert for too much stress not to join FPC in the case of insertion of FPC.
1) The bending radius of the FPC should be more than 1.4mm, and it should be bent evenly.
2) Do not dangle the LCD module by holding the FPC, or do not give any stress to it.
1) The module should be held on to the plain surface. Do not give any warping or twisting stress to
2) Please consider that GND can ground a modular metal portion etc. so that static electricity is not
3) Design guidance for touch panel (T/P)
Parameter
Input voltage
Resistor between terminals(XL-XR)
Resistor between terminals(YU-YD)
Line linearity(X direction)
Line linearity(Y direction)
Insuration resistance
Minimum tension for detecting
a) Example of housing design
the module.
charged to a module.
(2) Keep the gap, for example 0.3 to 0.7mm, between bezel edge and T/P surface.
(3) Insertion a cushion material is recommended.
(4) The cushion material should be limited just on the busbar insulation paste area.
(5) There is one where a resistance film is left in the T/P part of the end of the pole.
(1) If a consumer will put a palm on housing in normal usage, care should be taken as follows.
The reason is to avoid the bezel edge from contacting T/P surface that may cause a “short”
with bottom layer. (See Fig.11-3-1)
If it is over the transparent insulation paste area, a ”short” may be occurred.
Design to keep insulation from the perimeter to prevent from mis-operation and so on.
Min.
260
160
20
-
-
-
-
Typ.
615
400
5.0
-
-
-
-
1,200
Max.
800
1.5
1.5
7.0
0.8
-