LQ070Y3DG3A Sharp Electronics, LQ070Y3DG3A Datasheet - Page 11

no-image

LQ070Y3DG3A

Manufacturer Part Number
LQ070Y3DG3A
Description
Manufacturer
Sharp Electronics
Datasheet

Specifications of LQ070Y3DG3A

Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LQ070Y3DG3A
Manufacturer:
SHARP
Quantity:
1 000
7-2. Display position
7-3. Input data signals and display position on the screen
Image will not be displayed on the right position otherwise.
Phase difference of
[Note]
(Horizontal display direction)
(Vertical display direction)
(“DEN” signal)
Caution
DEN
When “DEN” signal is fixed low, 216 clocks are counted from Hsync negative edge and data from after are
available. If you need other timing, please use “DEN” signal.
36 lines are counted from Vsync negative edge and data from next line are available.
When “DEN” signal is active, “DEN” signal input continuously or fixed “L” in Vertical invalid data period.
Characteristics
HSYNC - DEN
Pulse width
Setup time
480・1
1・ 1
2・ 1
3・ 1
Symbol
THe
Tep
Tes
1・ 2
2・ 2
1・ 3
Display position of input data(V・ H)
Min.
88
5
G
B
R
Typ.
800
Tc-10
Max.
215
1・800
clock
clock
Unit
ns
480・800
Remark

Related parts for LQ070Y3DG3A