AD7994BRUZ-0 Analog Devices Inc, AD7994BRUZ-0 Datasheet - Page 26

no-image

AD7994BRUZ-0

Manufacturer Part Number
AD7994BRUZ-0
Description
IC ADC 12BIT 4CHAN I2C 16TSSOP
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD7994BRUZ-0

Data Interface
I²C, Serial
Number Of Bits
12
Sampling Rate (per Second)
188k
Number Of Converters
1
Power Dissipation (max)
2.2mW
Voltage Supply Source
Single Supply
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
16-TSSOP (0.173", 4.40mm Width)
Resolution (bits)
12bit
Sampling Rate
188kSPS
Input Channel Type
Single Ended
Supply Voltage Range - Analog
2.7V To 5.5V
Supply Current
1.4mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
EVAL-AD7994CBZ - BOARD EVALUATION FOR AD7994CBZ
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7994BRUZ-0
Manufacturer:
AD
Quantity:
1 222
Part Number:
AD7994BRUZ-0
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7994BRUZ-0REEL
Manufacturer:
MICROCHIP
Quantity:
5 700
AD7993/AD7994
READING DATA FROM THE AD7993/AD7994
Reading data from the AD7993/AD7994 is a 1-byte or 2-byte
operation. Reading back the contents of the alert status register
or the cycle timer register is a single-byte read operation, as
shown in Figure 29. This assumes the particular register address
has previously been set up by a single-byte write operation to
the address pointer register, as shown in Figure 26. Once the
register address has been set up, any number of reads can be
performed from that particular register without having to write
to the address pointer register again. If a read from a different
register is required, the relevant register address has to be
written to the address pointer register, and again, any number of
reads from this register may then be performed.
SDA
SCL
SDA
SCL
START BY
START BY
MASTER
MASTER
0
1
0
1
1
1
SERIAL BUS ADDRESS BYTE
SERIAL BUS ADDRESS BYTE
0
0
A3
FRAME 1
A3
FRAME 1
Figure 30. Reading Two Bytes of Data from the Conversion Result Register
A2
Figure 29. Reading a Single Byte of Data from a Selected Register
A2
SCL (CONTINUED)
SDA (CONTINUED)
A1
A1
AD7993/AD7994
A0
A0
ACK. BY
R/W
R/W
AD7993/AD7994
Rev. 0 | Page 26 of 32
ACK. BY
9
9
ALERT
FLAG
D7
1
D7
1
1
Reading data from the configuration register, conversion result
register, DATA
registers is a 2-byte operation, as shown in Figure 30. The same
rules apply for a 2-byte read as a 1-byte read.
When reading data back from a register on the AD7993 or the
AD7994, for example the conversion result register, if more than
two read bytes are supplied, the same or new data is read from
the AD7993/AD7994 without the need to readdress the device.
This allows the master to continuously read from a data register
without having to readdress the AD7993/AD7994.
ZERO
D6
D6
SINGLE DATA BYTE FROM AD7993/AD7994
MOST SIGNIFICANT DATA BYTE FROM
MOST SIGNIFICANT DATA BYTE FROM
CH
D5
D5
ID1
CH
D4
D4
AD7993/AD7994
AD7993/AD7994
ID0
HIGH
FRAME 2
FRAME 2
FRAME 2
D11
D3
D3
registers, DATA
D2
D10
D2
D1
D1/0
D9
D0
D0/0
D8
NO ACK. BY
NO ACK. BY
MASTER
LOW
MASTER
MASTER
ACK. BY
9
9
9
registers, or hysteresis
STOP BY
STOP BY
MASTER
MASTER

Related parts for AD7994BRUZ-0