MCP3550-50E/MS Microchip Technology, MCP3550-50E/MS Datasheet - Page 22

IC ADC 22BIT 2.7V 1CH 8MSOP

MCP3550-50E/MS

Manufacturer Part Number
MCP3550-50E/MS
Description
IC ADC 22BIT 2.7V 1CH 8MSOP
Manufacturer
Microchip Technology
Datasheets

Specifications of MCP3550-50E/MS

Data Interface
Serial, SPI™
Number Of Bits
22
Sampling Rate (per Second)
12.5
Number Of Converters
1
Voltage Supply Source
Single Supply
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
8-TSSOP, 8-MSOP (0.118", 3.00mm Width)
Resolution (bits)
22bit
Sampling Rate
12.5SPS
Input Channel Type
Differential
Supply Voltage Range - Analog
2.7V To 5.5V
Supply Current
120µA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
MCP355XDV-MS1 - BOARD DEV SENSOR APP MCP355XMCP355XDM-TAS - BOARD DEMO TINY APP SNSR MCP355X
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
MCP3550/1/3
5.2
During Shutdown mode, on the falling edge of CS, the
conversion process begins. During this process, the
internal oscillator clocks the delta-sigma modulator and
the SINC filter until a conversion is complete. This
conversion time is t
Figure
settled completely and there is no latency involved with
the digital SINC filter of the MCP3550/1/3.
The two modes of conversion for the MCP3550/1/3
devices are Single Conversion and Continuous
Conversion. In Single Conversion mode, a consecutive
conversion will not automatically begin. Instead, after a
single conversion is complete and the SINC filter have
settled, the device puts the data into the output register
and enters shutdown.
FIGURE 5-2:
FIGURE 5-3:
DS21950E-page 22
SCK (opt)
SDO/RDY
SDO/RDY
SCK (opt)
Int. Osc
Int. Osc
5-2. At the end of t
CS
Controlling Internal Conversions
and the Internal Oscillator
CS
t
CONV
CONV
Single Conversion Mode.
Continuous Conversion Mode.
t
CONV
and the timing is shown in
CONV
, the digital filter has
t
Hi-Z
CONV
Sleep
t
CONV
In Continuous Conversion mode, a consecutive
conversion will be automatic. In this mode, the device
is continuously converting, independent of the serial
interface. The most recent conversion data will always
be available in the Output register.
When the device exits Shutdown, there is an internal
power-up delay that must be observed.