M48T201Y-70MH1E STMicroelectronics, M48T201Y-70MH1E Datasheet - Page 19

IC SUPERVISOR TIMEKPR 5V 44-SOH

M48T201Y-70MH1E

Manufacturer Part Number
M48T201Y-70MH1E
Description
IC SUPERVISOR TIMEKPR 5V 44-SOH
Manufacturer
STMicroelectronics
Series
Timekeeper®r
Type
Clock/Calendar/NVSRAMr
Datasheet

Specifications of M48T201Y-70MH1E

Memory Size
External
Time Format
HH:MM:SS (24 hr)
Date Format
YY-MM-DD-dd
Interface
Parallel
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
44-SOH
Number Of Voltages Monitored
1
Monitored Voltage
3.3 V, 5 V
Manual Reset
Not Resettable
Watchdog
Watchdog
Battery Backup Switching
Backup
Supply Voltage (max)
5.5 V
Supply Voltage (min)
4.5 V
Supply Current (typ)
15000 uA
Maximum Power Dissipation
1000 mW
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
0 C
Power Fail Detection
Yes
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
497-2840-5
M48T201Y-70MH1
M48T201Y, M48T201V
3.5
Note:
Setting the alarm clock
Registers 7FFF6h-7FFF2h contain the alarm settings. The alarm can be configured to go off
at a prescribed time on a specific month, day of month, hour, minute, or second or repeat
every month, day of month, hour, minute, or second.
It can also be programmed to go off while the M48T201Y/V is in the battery backup to serve
as a system wake-up call.
Bits RPT5-RPT1 put the alarm in the repeat mode of operation.
configurations. Codes not listed in the table default to the once per second mode to quickly
alert the user of an incorrect alarm setting.
User must transition address (or toggle chip enable) to see flag bit change.
When the clock information matches the alarm clock settings based on the match criteria
defined by RPT5-RPT1, the AF (alarm flag) is set. If AFE (alarm flag enable) is also set, the
alarm condition activates the IRQ/FT pin. To disable alarm, write ’0’ to the alarm-date
register and RPT1-5. The IRQ/FT output is cleared by a READ to the flags register as
shown in
value of the alarm flag has been reset to '0.'
The IRQ/FT pin can also be activated in the battery backup mode. The IRQ/FT will go low if
an alarm occurs and both ABE (alarm in battery backup mode enable) and AFE are set. The
ABE and AFE bits are reset during power-up, therefore an alarm generated during power-up
will only set AF. The user can read the flag register at system boot-up to determine if an
alarm was generated while the M48T201Y/V was in the deselect mode during power-up.
Figure 8 on page 20
Figure 7.
Table 6.
RPT5
1
1
1
1
1
0
A0-A18
ACTIVE FLAG BIT
IRQ/FT
Figure
Alarm interrupt reset waveforms
Alarm repeat modes
RPT4
1
1
1
1
0
0
7. A subsequent READ of the flags register is necessary to see that the
illustrates the backup mode alarm timing.
RPT3
1
1
1
0
0
0
RPT2
1
1
0
0
0
0
ADDRESS 7FFF0h
15ns Min
RPT1
1
0
0
0
0
0
Table 6
Once per second
Once per minute
Once per month
Alarm setting
Once per hour
Once per year
Once per day
HIGH-Z
shows the possible
Clock operation
AI02331
19/37

Related parts for M48T201Y-70MH1E