ISL1220IUZ-T Intersil, ISL1220IUZ-T Datasheet - Page 7

IC RTC LP BATT BACK SRAM 10MSOP

ISL1220IUZ-T

Manufacturer Part Number
ISL1220IUZ-T
Description
IC RTC LP BATT BACK SRAM 10MSOP
Manufacturer
Intersil
Type
Clock/Calendar/Alarmr
Datasheet

Specifications of ISL1220IUZ-T

Memory Size
8B
Time Format
HH:MM:SS (12/24 hr)
Date Format
YY-MM-DD-dd
Interface
I²C, 2-Wire Serial
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
10-MSOP, Micro10™, 10-uMAX, 10-uSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
ISL1220IUZ-TTR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ISL1220IUZ-T
Manufacturer:
Vishay
Quantity:
1 600
General Description
The ISL1220 device is a low power real time clock with
timing and crystal compensation, clock/calendar, power fail
indicator, periodic or polled alarm, intelligent battery backup
switching, battery-backed user SRAM and separate F
and IRQ outputs.
The oscillator uses an external, low-cost 32.768kHz crystal.
The real time clock tracks time with separate registers for
hours, minutes, and seconds. The device has calendar
registers for date, month, year and day of the week. The
calendar is accurate through 2099, with automatic leap year
correction.
The ISL1220's powerful alarm can be set to any
clock/calendar value for a match. For example, every
minute, every Tuesday or at 5:23 AM on March 21. The
alarm status is available by checking the Status Register, or
the device can be configured to provide a hardware interrupt
via the IRQ pin. There is a repeat mode for the alarm
allowing a periodic interrupt every minute, every hour, every
day, etc.
The device also offers a backup power input pin. This V
pin allows the device to be backed up by battery or Super
Cap with automatic switchover from V
ISL1220 device is fully operational from 2.0V to 5.5V and the
clock/calendar portion of the device remains fully operational
down to 1.8V (Standby Mode).
Pin Description
X1, X2
The X1 and X2 pins are the input and output, respectively, of
an inverting amplifier. An external 32.768kHz quartz crystal
is used with the ISL1220 to supply a timebase for the real
time clock. Internal compensation circuitry provides high
accuracy over the operating temperature range from
-40°C to +85°C. This oscillator compensation network can
be used to calibrate the crystal timing accuracy over
temperature either during manufacturing or with an external
temperature sensor and microcontroller for active
compensation. The device can also be driven directly from a
32.768kHz source at pin X1.
FIGURE 7. STANDARD OUTPUT LOAD FOR TESTING THE
EQUIVALENT AC OUTPUT LOAD CIRCUIT FOR V
IRQ, F
DEVICE WITH V
AND
SDA
OUT
5.0V
DD
7
= 5.0V
100pF
1533Ω
DD
to V
FOR V
AND I
BAT
OL
OL
DD
. The entire
= 0.4V
= 3mA
= 5V
OUT
BAT
ISL1220
V
This input provides a backup supply voltage to the device.
V
supply fails. This pin can be connected to a battery, a Super
Cap or tied to ground if not used.
IRQ (Interrupt Output)
The IRQ output is an open drain active low configuration.
• Interrupt Mode. The pin provides an interrupt signal
Serial Clock (SCL)
The SCL input is used to clock all serial data into and out of
the device. The input buffer on this pin is always active (not
gated). It is disabled when the backup power supply on the
V
Serial Data (SDA)
SDA is a bidirectional pin used to transfer data into and out
of the device. It has an open drain output and may be ORed
with other open drain or open collector outputs. The input
buffer is always active (not gated) in normal mode.
An open drain output requires the use of a pull-up resistor.
The output circuitry controls the fall time of the output signal
with the use of a slope controlled pull-down. The circuit is
designed for 400kHz I
when the backup power supply on the V
F
• Frequency Output Mode. The pin outputs a clock signal
V
Chip power supply and ground pins. The device will operate
with a power supply from 2.0V to 5.5VDC. A 0.1µF capacitor
is recommended on the V
Functional Description
Power Control Operation
The power control circuit accepts a V
Many types of batteries can be used with Intersil RTC
products. For example, 3.0V or 3.6V Lithium batteries are
appropriate, and battery sizes are available that can power
the ISL1220 for up to 10 years. Another option is to use a
BAT
BAT
BAT
OUT
DD
output. This signal notifies a host processor that an alarm
has occurred and requests action. It is an open drain
active low output.
which is related to the crystal frequency. The frequency
output is user selectable and enabled via the I
an open drain active low output.
FIGURE 8. RECOMMENDED CRYSTAL CONNECTION
, GND
supplies power to the device in the event that the V
pin is activated to minimize power consumption.
(Frequency Output)
2
C interface speeds. It is disabled
DD
pin to ground.
X1
X2
DD
BAT
and a V
pin is activated.
2
BAT
C bus. It is
June 22, 2006
input.
FN6315.0
DD