TLE6244XXT Infineon Technologies, TLE6244XXT Datasheet - Page 5

no-image

TLE6244XXT

Manufacturer Part Number
TLE6244XXT
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of TLE6244XXT

Switch Type
Low Side
Power Switch Family
TLE 6244X
Input Voltage
-0.3 to 36V
Power Switch On Resistance
620mOhm
Output Current
1.1A
Number Of Outputs
18
Mounting
Surface Mount
Package Type
MQFP
Operating Temperature (min)
-40C
Operating Temperature (max)
150C
Operating Temperature Classification
Automotive
Pin Count
64
Lead Free Status / RoHS Status
Compliant
Final Data Sheet
1.3.1 Power Stage OUT8 (Condensed Description)
1.3.1.1 Control of OUT8 and VDD-Monitoring
1.3.1.2 Phase Relation IN8 - OUT8
1.3.1.3 Reset / Power Stage Diagnostics
1.3.1.4 Input Current
1.3.1.5 On Resistance
1.3.1.6 Parallel Connection of Power Stages
All low side switches are equipped with fault diagnostic functions:
- short-circuit to U
- short-circuit to ground: (SCG) can be detected if switches are turned off
- open load:
- overtemperature:
The fault conditions SCB, SCG, OL and OT will not be stored until an integrated filtering time is
expired (please note for PWM application). If, at one output, several errors occur in a sequence,
always the last detected error will be stored (with filtering time). All fault conditions are encoded
in two bits per switch and are stored in the corresponding SPI registers. Additionally there are
two central diagnostic bits: one specially for OT and one for fault occurrence at any output.
The registers can be read out via SPI. After each read out cycle the registers have to be cleared
by the DEL_DIA command.
OUT8 can be controlled by SPI or by the pin IN8 only, control by µs-bus is not possible. When
controlled by IN8 this power stage is functional if the voltage at the pin VDD is above 3,5V. In
SPI mode the power stage is fully supervised by the VDD-monitor.
If OUT8 is controlled by IN8, OUT8 will only be switched off by the overvoltage detection and
not by undervoltage detection.
The phase relation IN8 -> OUT8 is inverting.
OUT8 is active if IN8 is set to logic '1' (high level, see 3.4.2 ) in case of parallel access.
On executing the read instruction on RD_INP1/2 the inverted status of IN8 is read back.
If OUT8 is controlled by IN8, OUT8 will not be reseted by RST.
After reset parallel control (by IN8) is active for OUT8.
If UVDD < 4.5V errors are not stored because of the active RST of the external Regulator. Nev-
ertheless
OUT8 is protected against overload.
The control input IN8 has an internal pull-down current source. Thus the input currents I IN8
are positive (flow into the pin).
For OUT8 and 3.5V < UVDD < 4.5V R on increases (see 3.8.5).
Parallel connection of power stages with OUT8 and parallel control is prohibited (inverting
input IN8). Control via SPI is possible. See 1.13.
Batt
:
(SCB) can be detected if switches are turned on
(OL) can be detected if switches are turned off
(OT) will only be detected if switches are turned on
5
TLE 6244X
V4.2, 2003-08-29