MCZ33996EK Freescale, MCZ33996EK Datasheet - Page 14

no-image

MCZ33996EK

Manufacturer Part Number
MCZ33996EK
Description
Manufacturer
Freescale
Datasheet

Specifications of MCZ33996EK

Switch Type
Low Side
Power Switch Family
33996
Input Voltage
-0.3 to 7V
Power Switch On Resistance
550mOhm
Output Current
900mA
Number Of Outputs
16
Mounting
Surface Mount
Supply Current
4mA
Package Type
SOIC W EP
Operating Temperature (min)
-40C
Operating Temperature Classification
Automotive
Pin Count
32
Power Dissipation
1.7W
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCZ33996EK
Quantity:
588
Part Number:
MCZ33996EK
Manufacturer:
FREESCALE
Quantity:
321
Part Number:
MCZ33996EK
Manufacturer:
FREESCALE
Quantity:
321
Part Number:
MCZ33996EK
Manufacturer:
FREESCALE
Quantity:
20 000
Company:
Part Number:
MCZ33996EK
Quantity:
48
Part Number:
MCZ33996EKR2
0
on output drain-to-source voltage (V
is designed to provide protection to loads that experience
more than expected currents and require fast shutdown. The
33996 is designed to operate in both modes with full device
protection.
PWM ENABLE REGISTER
PWM controlled. The first 8 bits of the 24 bit SPI message
word are used to identify the PWM enable command, and the
remaining 16 bits are used to enable and disable the PWM of
the output drivers.
outputs as PWM. A logic [1] in the PWM Enable register will
set the specific output as a PWM. Power-ON Reset or the
RST
register to logic [0].
AND/OR CONTROL REGISTER
which the PWM pin controls the output driver. A logic [0] in
the AND /OR Control register will AND the PWM input pin with
the ON /OFF Control register bit. Likewise, a logic [1] in the
AND /OR Control register will OR the PWM input pin with the
ON /OFF Control register bit (see
14
33996
LOGIC COMMANDS AND REGISTERS
INTRODUCTION
The PWM Enable register determines the outputs that are
A logic [0] in the PWM Enable register will disable the
The AND /OR Control register describes the condition by
pin or the RESET command will set the PWM Enable
Figure
DS
) > 2.7V. This feature
12). For the AND /
OR control to occur, the PWM Enable bit must be set to
logic [1].
SERIAL OUTPUT (SO) RESPONSE REGISTER
All logic [1s] received by the MCU via the SO pin indicate
fault. All logic [0s] received by the MCU via the SO pin
indicate no fault. All fault bits are cleared on the positive edge
of
to 0. SO bits 21 to 16 will always return logic [0]. Bit 22
provides over-voltage condition status and bit 23 is set when
any fault is present in the IC. The timing between two write
words must be greater than 450μs to allow adequate time to
sense and report the proper fault status.
RESET COMMAND
following registers to a POR state (refer to
Registers are not affected by the RESET command.
On/Off control Bit
On/Off Control Bit
PWM IN
AND/OR Control Bit
PWM IN
CS
Fault reporting is accomplished through the SPI interface.
The RESET command turns all outputs OFF and sets the
• ON/OFF Control Register
• SFPD Control Register
• PWM Enable Register
• AND/OR Control Register
The Open Load Current Enable and the Global Shutdown
. SO bits 15 to 0 represent the fault status of outputs 15
Figure 12. PWM Control Logic Diagram
On/Off Control Bit
PWM Enable Bit
Analog Integrated Circuit Device Data
Freescale Semiconductor
Table
6).
To Gate
Control

Related parts for MCZ33996EK