TMC22151KHC Fairchild Semiconductor, TMC22151KHC Datasheet - Page 51

no-image

TMC22151KHC

Manufacturer Part Number
TMC22151KHC
Description
Manufacturer
Fairchild Semiconductor
Datasheet

Specifications of TMC22151KHC

Screening Level
Commercial
Package Type
MQFP
Pin Count
100
Lead Free Status / RoHS Status
Compliant
PRODUCT SPECIFICATION
For PAL comb filters the LYE, LME, and LPE errors signals
are always selected by default. In this way the error signals
into the XLUT always represent the comb filter being imple-
mented. The resolution of the error signals selected is con-
trolled by the XIP[1:0] register bits as shown in Table 6:
XLUT Input Selection. The position of these error signals on
the XLUT input address X[7:0] is also shown.
Table 6. XLUT Input Selection
The selected comb fail signals are translated by the user-
programmed configuration within the 256*5 XLUT into the
mix signal (K) which controls the 30 levels of cross-fade
between the weighted comb filter and the band split filters.
The 1 to 31 mix signal is modified on the input to the cross-
fade to produce a 0 to 32 control signal, as shown in Table 7.
Table 7. XLUT Output Function.
OUTPUT
XIP[1:0]
XLUT
MERR
00
01
10
11
YERR
PERR
0
1
2
3
:
2 bits of phase error (X[7:6]), 3 bits of
chroma (X[5:3]) and luma magnitude error
(X[3:0]).
4 bits of chroma (X[7:4]) and luma
magnitude error (X[3:0]).
3 bits of phase error (X[7:5]), 3 bits of
chroma magnitude error (X[4:2]), and 2
bits of luma magnitude error (X[1:0]).
4 bits of phase error (X[7:4]) and chroma
magnitude error (X[3:0]).
Special function (e.g. luma comb and HPF
on chroma)
0 - 100% Bandsplit
2
3
:
XIP[1:0]
XLUT
Input
Select
Function
X[7:0]
K
Figure 20. XLUT Input Selection
XLUT
Table 7. XLUT Output Function.
The special function assigned to K = 0 is programmed into
the XSF[1:0] register bits, as shown in Table 8.
Table 8. XLUT Special Function Definitions
The “Flat with notch” selection passes the FLAT input
through onto the luminance channel and selects the notch
filter, centered at 0.25 of the normalized clock frequency.
This mode is therefore only useful with inputs at 4*Fsc or in
cases when a notch at 0.25 of the normalized clock
frequency is adequate for application.
The XLUT output, is fed through a bypassable low-pass
filter KLPF to avoid switching between comb and simple
decoders on a pixel by pixel basis. When the special function
is selected (K = 0) the input to the KLPF is held and the filter
is automatically bypassed. The output of the XLUT can be
externally monitored by reading XOP[4:0] in register 4Bh.
OUTPUT
KIP
XLUT
00
01
10
11
16
29
30
31
:
1-0
16 - 50% Bandsplit, 50% Comb
:
29
30
32 - 100% Comb
Filter
flat with notch
flat with notch
XLUT special function selection
simple
comb
Y
MUX
FAST
2:1
K
(cont.)
simple
simple
comb
comb
C
65-22x5y-61
TMC22x5y
K[4:0]
51

Related parts for TMC22151KHC