IDT82V1671J IDT, Integrated Device Technology Inc, IDT82V1671J Datasheet - Page 70

IDT82V1671J

Manufacturer Part Number
IDT82V1671J
Description
Manufacturer
IDT, Integrated Device Technology Inc
Datasheet

Specifications of IDT82V1671J

Number Of Channels
4
On-hook Transmission
Yes
Polarity Reversal
Yes
On-chip Ring Relay Driver
Yes
Operating Supply Voltage (typ)
3.3V
Operating Temp Range
-40C to 85C
Package Type
PLCC
Operating Temperature Classification
Industrial
Pin Count
28
Mounting
Surface Mount
Operating Current
95mA
Operating Supply Voltage (max)
3.465V
Operating Supply Voltage (min)
3.135V
Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IDT82V1671J
Manufacturer:
BROADCOM
Quantity:
457
Part Number:
IDT82V1671J
Manufacturer:
IDT
Quantity:
20 000
RSLIC & CODEC CHIPSET
GREG16: Level Meter Count_Number High 3 bits; Level Meter On/Off, Channel Selection and Once/Continuous Measurement, Read/Write
GREG17: Level Meter Result Register (Low), Read Only (30H)
GREG18: Level Meter Result Register (High), Read Only (31H)
GREG19: FSK Flag Length Register, Read/Write (32H/B2H)
GREG20: FSK Data Length Register, Read/Write (33H/B3H)
(2FH/AFH)
LM_ONCE
LM_EN
LM_CS
LM_CN
This register contains the low byte of the level meter result. The default value of LMRL[7:0] bits is 0.
This register contains the high byte of the level meter result. The default value of the LMRH[7:0] is 0.
The flag signal is a stream of '1'. It is transmitted between two message bytes during the Caller ID data transmission.
This register is used to set the number of the flag bits '1'. The value of FSK_FL[7:0] bits is valid from 0 to 255(d).
The default value of 0(d) means that no flag signal will be sent out.
This register is used to set the length of the data bytes that will be transmitted except the flag signal.
The value of the FSK_DL[7:0] bits is valid from 0 to 64(d). Any value larger than 64(d) will be taken as 64(d) by the DSP.
Command
Command
Command
Command
Command
I/O data
I/O data
I/O data
I/O data
I/O data
LM_ONCE
Execution mode of the integrator in level meter. The integration can be executed continuously or once after every initia-
tion.
LM_ONCE = 0:
LM_ONCE = 1:
Level meter function enable. This bit starts or stops level metering.
LM_EN = 0:
LM_EN = 1:
Level meter channel selection. The LM_CS[1:0] bits determine the data on which channel will be level metered.
LM_CS[1:0] = 00: The data on Channel 1 will be input to the level meter (default);
LM_CS[1:0] = 01: The data on Channel 2 will be input to the level meter;
LM_CS[1:0] = 10: The data on Channel 3 will be input to the level meter;
LM_CS[1:0] = 11: The data on Channel 4 will be input to the level meter.
Level meter count number high 3 bits LM_CN[10:8]. Refer to the description of GREG15 for details.
R/W
R/W
R/W
b7
b7
b7
b7
b7
0
0
LM_EN
b6
b6
b6
b6
b6
0
0
0
0
0
The integrator runs continuously (default);
The integrator runs only once. To start again, the LM_EN bit must be set from 0 to 1 again.
disabled, level metering stops (default);
enabled, level metering starts.
LM_CS
b5
b5
b5
b5
b5
1
1
1
1
1
LM_CS[0]
70
b4
b4
b4
b4
b4
0
1
1
1
1
FSK_FL[7:0]
FSK_DL[7:0]
LMRH[7:0]
LMRL[7:0]
Reserved
b3
b3
b3
b3
b3
1
0
0
0
0
b2
b2
b2
b2
b2
1
0
0
0
0
IDT82V1671/IDT82V1671A, IDT82V1074
LM_CN[10:8]
b1
b1
b1
b1
b1
1
0
0
1
1
b0
b0
b0
b0
b0
1
0
1
0
1

Related parts for IDT82V1671J