PXB4219EV34NP Infineon Technologies, PXB4219EV34NP Datasheet - Page 54

no-image

PXB4219EV34NP

Manufacturer Part Number
PXB4219EV34NP
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of PXB4219EV34NP

Data Rate
2.048Mbps
Number Of Channels
1
Operating Supply Voltage (typ)
3.3V
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Lead Free Status / RoHS Status
Not Compliant
4.3.1.4
The four CAS bits for each timeslot are transported within one multiframe from the framer
to the IWE8. A signalling buffer in the internal RAM (256 x 4 x 2bit) holds the CAS bits
from the framer interface. The activation of CAS packetization can be done via “p_cas”
in the register “pcfN”.
The CAS bits will be packed in a signalling substructure after the payload of one
multiframe has been packetized.
4.3.1.5
Normally the framer device is responsible for signalling freezing or signalling
conditioning in case of line failure. If the framer doesn’t support the feature the IWE8 can
also fulfill the requirements according to Bellcore TR-NWT-000170 [14].
Pin “FRLOS = 1" indicates that the CAS information from the framer device is invalid and
CAS conditioning or freezing upstream is starting. This state remains active until valid
CAS bits are available indicated by “FRLOS = 0".
CAS freezing means that the last valid CAS information is repeated as long as the error
cause exists. In case of CAS conditioning for each timeslot individual CAS conditioning
nibbles are sent instead. Selection between both procedures is done by setting
“sig_cond” in the “AAL Receive Reference Slot”. If the channel bandwidth is one slot, the
signalling conditioning nibbles are defined in the field “next_slot_nr” of the “AAL Receive
Reference Slot”. If the channel bandwidth is more than one slot, the signalling
conditioning nibbles are defined in the “sig_cond_nibble” of the “AAL Receive
Continuation Slot”. In the latter case the signalling conditioning nibbles defined in the first
“AAL Receive Continuation Slot” are used for the first two slots.
Table 15
Slot Number
1
2
3
N
Data Sheet
Transport of CAS Information
CAS Conditioning and Freezing Upstream
Definition of the CAS Signalling Conditioning Nibbles.
Channel Bandwidth = 1 Slot
“next_slot_nr” of the “AAL
Receive Reference Slot”
-
-
-
54
PXB 4219E, PXB 4220E, PXB 4221E
Channel Bandwidth >= 2 Slots
“sig_cond_nibble” of the first “AAL
Receive Continuation Slot”
“sig_cond_nibble” of the first “AAL
Receive Continuation Slot”
“sig_cond_nibble” of the second
“AAL Receive Continuation Slot”
“sig_cond_nibble” of the N-1th
“AAL Receive Continuation Slot”
Operational Description
IWE8, V3.4
2003-01-20