S82Y-J05K FOR S82J-50W Omron, S82Y-J05K FOR S82J-50W Datasheet - Page 5

no-image

S82Y-J05K FOR S82J-50W

Manufacturer Part Number
S82Y-J05K FOR S82J-50W
Description
S82J-50w COVER
Manufacturer
Omron
Series
S82Jr
Datasheets

Specifications of S82Y-J05K FOR S82J-50W

Accessory Type
Cover
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
S82J 50W Power Supplies
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
S82Y-J05KFORS82J-50W
S82YJ05KFORS82J50W
Specifications Table
Note: 1. DC inputs are not included in safety standard approvals.
Item
Additional
function
function
Other
5
2. At 100% load for rated input voltage (100 VAC or 200 VAC)
3. The output specification is defined at the power supply output terminals.
4. For resetting, turn OFF the power supply, leave for more than one minute, and then turn ON the power supply.
5. For resetting, turn OFF the power supply, leave for more than 90 seconds min. (3 minutes for the 600-W models), and then turn
6. To ensure the Emission Enclosure rating ferrite ring cores (recommended model: S82Y-JC-T) should be used on all cabling.
7. To ensure the Emission AC Mains rating for EN50081-1 (only for 230 VAC input), a noise filter (recommended models:
8. Class 2 approval on 10-W (12, 15, 24 V), 25-W (12, 15, 24 V) and 50-W (24 V) models.
9. The weight indicated is the weight of the open-frame type. (Includes the covers for 300-W and 600-W models)
ON the power supply.
S82Y-JF3-N for 300-W, S82Y-JF6-N for 600-W) should be used on the input lines.
Switching Power Supply
Protection-ON alarm
indicator
Parallel operation
Series operation
Ambient
temperature
temperature
Ambient
humidity
humidity
Dielectric strength
Dielectric strength
Insulation resistance
Vibration resistance
Shock resistance
Terminal screw
tightening
Output indicator
Electromagnetic interfer-
ence (See Note 2.)
EMC
EMC standards
Approved
standards
standards
Weight (See Note 9.)
Mean time between
failures
Life expectancy
– continued from previous page
Operat-
ing
Storage
Operat-
ing
Storage:
UL
CSA
VDE
100 to 240 VAC input
10 W
No
No
No
See the derating curve in the Engineering Data Section.
-25_C to 65_C (-13_F to 149_F) with no condensation and icing
25% to 85%
25% to 90%
3.0 k VAC, 50/60 Hz for 1 min (between all inputs and all outputs)
2.2 k VAC, 50/60 Hz for 1 min (between all inputs and GR terminal)
1.0 k VAC, 50/60 Hz for 1 min (between all outputs and GR terminal)
100 MW min. (between all outputs and all inputs/GR terminals at 500 VDC)
10 to 55 Hz, 0.375-mm double amplitude for 2 h each in X, Y, and Z directions
300 m/s
0.74 N  m
Yes (green)
Conforms to FCC Class A
Emission Enclosure: EN55011 class A
Emission AC Mains: EN55011 class A
Immunity ESD:
Immunity RF-interference: ENV50140: 10 Vm (80 MHz to 1 GHz) (level 3)
Immunity Conducted Disturbance: ENV50141: 10 V (0.5 to 80 MHz) (level 3)
Immunity Burst
Conforms to EN50081-2 and EN50082-2
UL508 (Listing), 1950, Class 2
(per UL1310) (See Note 8.)
CSA C22.2 No. 14, No. 950,
Class 2 (See Note 8.)
EN50178 (VDE0160) and EN60950
Terminal types (only terminal part): VDE0106/P100
250 g
max.
135,000 hrs min. (MTBF is calculated according to the probability of accidental device fail-
ures, and indicates reliability of devices. It does not necessarily represent a life of the product.
10 yrs. min. (Used at 40_C at the rated input with a 50% load, standard installation).
S82J
2
, 3 times each in X, Y, and Z directions
25 W
350 g
max.
EN61000-4-2:
EN61000-4-4
50 W
Yes
400 g
max.
100 W
(24V)
UL508 (Listing), 1012, 1950
CSA C22.2 No. 14, No. 950
500 g
max.
4 kV contact discharge (level 2)
8 kV air discharge (level 3)
2 kV power-line (level 3)
2 kV output line (level 4)
120 or 240 VAC
(selected
automatically)
100 W
(5, 12,
15 V)
1.08 N  m
1,000 g max
150 W
120 or 230 VAC
(selectable)
300 W
Yes (color, red)
Yes, 5 units max.
Conforms to
EN50081-2 and
EN50082-2 (See Note
6.) With noise filter,
confirms to EN50081-1
(See Note 6 and 7.)
UL508/1012
CSA EB1402C
2,000 g
max.
600 W
2,500 g
max.

Related parts for S82Y-J05K FOR S82J-50W