MM4KP AC110 Omron, MM4KP AC110 Datasheet - Page 9

no-image

MM4KP AC110

Manufacturer Part Number
MM4KP AC110
Description
RELAY
Manufacturer
Omron
Series
MMKr
Datasheet

Specifications of MM4KP AC110

Relay Type
General Purpose
Contact Form
4PDT (4 Form C)
Contact Rating (current)
5A
Switching Voltage
250VAC, 250VDC - Max
Coil Type
Latching, Dual Coil
Coil Current
35mA
Coil Voltage
110VAC
Turn On Voltage (max)
88 VAC
Mounting Type
Socket
Termination Style
14 Pin Socketable
Circuit
4PDT (4 Form C)
Contact Rating @ Voltage
5A @ 220VAC
Control On Voltage (max)
88 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Control Off Voltage (min)
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
MM4KPAC110
MM4KPAC110NC
Ambient Temperature vs.
Set and Reset Voltage
MM4KP AC (60 Hz)
MM4KP DC
Number of Relays: 5
Number of Relays: 5
Ambient temperature (°C)
Ambient temperature (°C)
Set voltage
Reset voltage
Set voltage
Reset voltage
Ambient Temperature vs.
Coil Temperature Rise
MM4KP 110 VAC (60 Hz)
MM4KP DC
Number of Relays: 5
Number of Relays: 5
Ambient temperature (°C)
Ambient temperature (°C)
Contact carry current
Contact carry current
Set coil
Reset coil
Set coil
Reset coil
60 min.
60 min.
Malfunctioning Shock
MM4(X)KP
Number of samples: 3
Measurement conditions: Impose a shock of
50 m/s
times each with the Relay energized and not
energized to check the shock values that cause
the Relay to malfunction.
2
in the ±X, ±Y, and ±Z directions three
Shock direction
60 min.
60 min.
Unit: m/s
Reset
60 min.
60 min.
2