D4BL-3CRB-A Omron, D4BL-3CRB-A Datasheet

Contact OSTI For Purchase

D4BL-3CRB-A

Manufacturer Part Number
D4BL-3CRB-A
Description
Contact OSTI For Purchase
Manufacturer
Omron
Series
D4BLr
Datasheets

Specifications of D4BL-3CRB-A

Contact Configuration
DPST-1NC / 1NO + SPST-NC
Contact Voltage Ac Max
250V
Contact Current Ac Max
10A
Switch Operation
ON
Switch Terminals
Screw
Contact Current Max
10A
Lead Free Status / RoHS Status
na
Lead Free Status / RoHS Status
na
Release Protective Cover Locks Using
Controller Signals or Pushbutton Switches after
the Cutting Tool Stops Moving Due to Inertia
• A mechanical lock is applied automatically when the Operation Key
• Conforms to EN (TÜV) standards corresponding to the CE marking.
• Certified by UL, CSA, BIA, SUVA and CCC standards.
• The Switch contact is opened by a direct opening mechanism (NC
• Auxiliary release key ensures easy maintenance and unlocks the
• Tough aluminum die-cast body incorporating a switch box with
• Equipped with a horizontal and vertical conduit opening.
• Models incorporating easy-to-see indicators for monitoring and
• The mounting direction of the head can be changed to allow the
Note: Be sure to read the “Safety Precautions” on page 13 and the
Model Number Structure
■ Model Number Legend
Switch
1. Conduit Size (2-conduit)
2. Built-in Switch (with Safety Switch and Lock Monitor Switch
3. Head Mounting Direction
4. Door Lock and Release (Auxiliary Release Key is
5. Indicator
is inserted. A high level of safety is achieved using a mechanism
where the lock is only released when voltage is applied to the
solenoid.
contacts only) when the protective cover is opened. Direct opening
mechanism that is EN-certified is indicated by
door in the case of a power failure.
degree of protection satisfying IP67, UL, and CSA TYPE6P, 13.
those using an adjustable Operation Key for a swinging door are
available.
Operation Key to be inserted from four directions.
Guard Lock Safety-door Switch
D4BL
D4BL -
1: PG13.5
2: G1/2
3: 1/2-14NPT
Contacts)
C: 1NC/1NO (slow-action) + 1NC (slow-action)
D: 2NC (slow-action) + 1NC (slow-action)
R: Four mounting directions possible (right-side mounting at
Incorporated by All Models)
A: Mechanical lock/24-VDC solenoid release
B: Mechanical lock/110-VAC solenoid release
G: 24-VDC Solenoid lock/Mechanical release
Blank: Without indicator
A:
“Precautions for All Safety Door Switches”.
shipping)
10 to 115 VAC or VDC driving (with orange and green LED
indicator unit)
1
http://www.ia.omron.com/
2
3
4
-
5
on the Switch.
Operation Key (Order Separately)
1. Operation Key Type
D4BL - K
1: Horizontal mounting
2: Vertical mounting
3: Adjustable mounting (Horizontal)
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
1
1

Related parts for D4BL-3CRB-A

D4BL-3CRB-A Summary of contents

Page 1

... Indicator Blank: Without indicator 115 VAC or VDC driving (with orange and green LED indicator unit) http://www.ia.omron.com/ on the Switch. Operation Key (Order Separately) D4BL - Operation Key Type 1: Horizontal mounting 2: Vertical mounting 3: Adjustable mounting (Horizontal) (c)Copyright OMRON Corporation 2007 All Rights Reserved. 1 ...

Page 2

... Horizontal mounting 2: Vertical mounting 3: Adjustable mounting (Horizontal) With LED indicator 1NC/1NO+ 1NC (Slow-action) (Slow-action) D4BL-1CRA-A D4BL-1CRB-A D4BL-2CRA-A D4BL-2CRB-A D4BL-3CRA-A D4BL-3CRB-A D4BL-1CRG-A D4BL-2CRG-A D4BL-3CRG-A Model (c)Copyright OMRON Corporation 2007 All Rights Reserved. D4BL 1 Without indicator With LED indicator 2NC+ 1NC 2NC+ 1NC ...

Page 3

... BIA SUVA UL CSA CQC (CCC) Indicator model AC- 115 V Current Make Break (c)Copyright OMRON Corporation 2007 All Rights Reserved. D4BL Standard File No. EN60947-5-1 R9451050 (certified direct opening) GS-ET-19 Mechanical lock: 9402293 Solenoid lock: 1998 20462-01 SUVA E6186/2.d UL508 E76675 CSA C22.2, No.14 LR45746 GB14048 ...

Page 4

... Although the switch box is protected from dust, oil or water penetration, do not use the D4BL in places where dust, oil, water, or chemicals may enter through the key hole on the head, otherwise Switch damage or malfunctioning may occur. ...

Page 5

... Stroke Operation Key 22 21 insertion comple- tion position on the Switch. (c)Copyright OMRON Corporation 2007 All Rights Reserved. D4BL Operation Key Lock plate Rotating drum Operation plunger Seal ring (NBR) Auxiliary plunger Seal packing (NBR) Rotating lever Safety switch Seal packing (NBR) Conduit opening Ground terminal M3 ...

Page 6

... Indicator (Green: 34.2 Solenoid ON). (123.5) 74 ±0.1 6.8 100 ±0.1 +1 Conduit opening 112 0 Indictor (Orange: Switch OFF) (c)Copyright OMRON Corporation 2007 All Rights Reserved. D4BL Four, M3.5 head clamping screws 31 37.5 Lock protection cap Four, 5.3 dia. mounting holes +1 86 Four, M4 ...

Page 7

... M4 Allen-head bolt (c)Copyright OMRON Corporation 2007 All Rights Reserved. D4BL Red 53.7 13 5.3 x 7.3 long mounting hole 25.8 40±0.15 52.4 15.6 36 5.3 11.9 7.5 20 11.8 5.6 2.6 4 dia. 7 ...

Page 8

... Vertical Mounting D4BL + D4BL-K2 Red 54.5 min. 58 max. (41) Adjustable Mounting (Horizontal) D4BL + D4BL-K3 Red 81.5 min. 85 max. (41) Note: 1. Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions the above diagrams, the Operation Key is inserted from the front. http://www.ia.omron.com/ Horizontal direction Operation Key insertion radius R ≥ ...

Page 9

... Four terminal plates Two, 7 dia. Two LED indicators (7) (16) 26.8 53.2 57.2 (16) 0.3 5.6 (35) 26.2 (61.2) ■ Internal Circuit Diagram Indicator 10 to 115 VAC/ Constant-current diode http://www.ia.omron.com/ 2 10.6 (12.6) Solenoid E1 (+) E2 (−) LED (c)Copyright OMRON Corporation 2007 All Rights Reserved. D4BL 9 ...

Page 10

... Orange: Lights when the solenoid turns ON. Green: Lights when power turns ON. E1 (+) (− Auxiliary circuit (monitor circuit) (c)Copyright OMRON Corporation 2007 All Rights Reserved. D4BL (Power supply side) E1 (+) 31 32 Solenoid E2 (−) LED (orange) LED (green) (Ground side) Safety circuit (Power supply side) ...

Page 11

... Connection Example with OMRON’s G9SA Safety Relay Unit G9SA-321-T@ (24 VAC/VDC) + D4BL-@A-@, @B-@ (Mechanical Lock Type) Circuit Diagram (Manual Reset) Lock release signal KM1 KM2 Guard S1 OPEN Stop signal A1 A2 T11 T12 T21 Timing Chart Limit switch S1 Guard Lock Safety-door ...

Page 12

... G9SA-301 (24 VAC/VDC) + D4BL-@G-@ (Solenoid Lock Type) Circuit Diagram (Auto-reset) Lock signal OPEN 11 Operation signal A1 A2 T11 T12 T21 T23 T22 Timing Chart Limit switch S1 Guard Lock Safety-door Switch S2 Operation signal Lock signal K1 and K2 (NC) K1 and K2 (NO) KM1 and KM2 (NC) KM1 and KM2 (NO) http://www ...

Page 13

... Conduit cap switch-mounting screw Auxiliary Release Key • The auxiliary release key is used to unlock the D4BL in case of emergency or in case the power supply to the D4BL fails. • Use the enclosed Release Key to change the lock from LOCK to UNLOCK so that the lock will be released and the door can be opened ...

Page 14

... Incorrect than ±0.3 Incorrect Greater than ±0.3 • The Operation Key for the D4BL is different from the one for the D4BS. http://www.ia.omron.com/ Head Direction • The head can be mounted in four directions by loosening the four screws holding the head. To remove the head, turn the head at the surface mating with the Switch body shown in figures (A) and (B) below ...

Page 15

... Properly attach and securely tighten the provided conduit cap to the unused conduit opening to the suitable tightening torque when wiring the D4BL. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. ...

Page 16

... Injury may result. • Do not drop the Switch. Doing so may prevent the Switch from functioning to its full capability. • Do not under any circumstances disassemble or modify the Switch. Doing so may cause malfunction. (c)Copyright OMRON Corporation 2007 All Rights Reserved. C-1 ...

Page 17

... Key may damage the Switch or affect machine safety. • Do not operate the Switch with anything other than the special OMRON Operation Key, otherwise the Switch may break or the safety of the system may not be maintained. • Do not impose excessive force on the Operation Key while the Key is inserted into the Switch or drop the Switch with the Operation Key inserted ...

Page 18

... Do not impose shock or vibration on the Actuator while it is fully pressed. Otherwise, the Actuator will partially abrade and an actuation failure may result. io (Constant current) t (c)Copyright OMRON Corporation 2007 All Rights Reserved. C-3 ...

Page 19

... Use gold-plated contacts, which are ideal for handling minute voltage or current loads. 3. The contacts of the Switch used for an emergency stop must be normally closed with a positive opening mechanism. (c)Copyright OMRON Corporation 2007 All Rights Reserved. C-4 ...

Page 20

... Power However, since the charging current supply to C flows into the contacts when they are closed, contact welding may occur. (c)Copyright OMRON Corporation 2007 All Rights Reserved. when it reacts with moisture. 3 Element selection Use the following as guides for C and R values 0.5 μ F per contact current ( Ω ...

Page 21

... If there is silicone oil, silicone sealant, or wire covered with silicone close to the Switch, attach a contact protection circuit to suppress the arcing of the Switch or eliminate the source of Correct silicone gas generation. (c)Copyright OMRON Corporation 2007 All Rights Reserved. Correct Correct Separate the Switch ...

Page 22

... When storing the Switch, make sure that the location is free of corrosive gas, such HNO does not have a high temperature or humidity. • Be sure to inspect the Switch before use if it has been stored for three months or more. http://www.ia.omron.com/ Correct , dust and 3 2 (c)Copyright OMRON Corporation 2007 All Rights Reserved. C-7 ...

Page 23

... Contact welding due to an incorrectly connected power source. Foreign materials or oil penetrated into the contact area. • Use a protective box. (c)Copyright OMRON Corporation 2007 All Rights Reserved. Remedy • Change the design of the dog or cam and smooth the contacting surface of the cam. ...

Page 24

... Lead Crimp terminal Terminal Terminal screw screw Terminal Terminal Incorrect Wiring Incorrect Crimped location facing down Lead Crimp terminal Terminal Terminal screw screw Terminal Terminal Too close to maintain dielectric strength http://www.ia.omron.com/ Correct (c)Copyright OMRON Corporation 2007 All Rights Reserved. C-9 ...

Page 25

... When transferring devices and equipment, be sure to keep one copy of the Operating Manual and pack another copy with the device or equipment so the person receiving it will have no problem operating it. • Related International Standards: ISO 12100 Basic Concepts, General Principles for Design IEC 61508 Functional Safety of Electrical/Electronic/Programmable Electronic Safety-related Systems http://www.ia.omron.com/ WARNING (c)Copyright OMRON Corporation 2007 All Rights Reserved. ...

Page 26

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specifi ed) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords