CQM1-TC201 Omron, CQM1-TC201 Datasheet - Page 4

no-image

CQM1-TC201

Manufacturer Part Number
CQM1-TC201
Description
4 LOOP,THERMOCPLE IN, NPN OUT
Manufacturer
Omron
Datasheet

Specifications of CQM1-TC201

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
B7A Link Interface Modules
A wire-saving B7A Link for remote I/O consists of master
modules mounted to the PLC and remote terminal blocks
connected to I/O devices. The terminal blocks can be
located up to 500 m way using a single cable.
J B7A LINK MASTER MODULES
J SPECIFICATIONS
Note: 1. Input mode setting allows selection between 16-point input and 15-point input + 1 error input.
For more details on the B7A Master Link Interface Modules, refer to the CQM1 Dedicated I/O Modules Operation Manual (W238).
I/O classification
16-point output
32-point output
16-point input
32-point input
16-point input/16-point output
Item
No. of I/O points
Transmission method
Transmission distance
Transmission speed
I/O word allocation (See Note 4)
Required power supply
Current consumption (module as part of CQM1)
Just two wires transmit data, simplifies installation and trou-
bleshooting
High-speed (100 m max. at 3 ms) and long distance (500 m
max. at 19.2 ms) configurations available
Wide range of transistor and relay blocks to meet application
needs
Transmission distance up to 500 m
Master acts like a high-density I/O module connecting 16 or
32 points to the controller with just two or three wires
Supports 16-point input, output, mixed I/O and 10-point B7A
terminal blocks and printed circuit board modules
Output modules offer Hold and Load OFF handling of trans-
mission errors
2. Input mode setting allows selection between 32-point input and 30-point input + 2 error inputs.
3. The transmission distance varies with the transmission speed and depends on where power is applied:
4. For addressing, words are allocated in sequence according to the location of the B7A Master on the PLC, as with other CQM1
For normal speed setting:
If B7A Master Link and the B7A input and output modules each have power supplies, the transmission distance is 500 m. If one
power supply is attached, the transmission distance is 100 m.
For high-speed setting:
If B7A Master Link and the B7A input and output modules each have power supplies, the transmission distance is 100 m. If one
power supply is attached, the transmission distance is 50 m.
I/O modules.
Model
CQM1-B7A02
CQM1-B7A03
CQM1-B7A12
CQM1-B7A13
CQM1-B7A21
Transmission capabilities
Long distance (19.2 ms) and high-speed (3 ms) systems, selectable
CQM1-B7A21
16 inputs,
16 outputs
(See Note 1)
Single-direction, time-division multiplex
Long distance: 500 m max. or 100 m max.
High-speed: 100 m max. or 50 m max. (See Note 3)
Normal: 19.2 ms (typical); 31 ms max.
High-speed: 3 ms (typical); 5 ms max.
1 word each
for input and
output
(2 words total)
0.11 A min.
100 mA max., 5 VDC
g
(
Programmable Controller
CQM1-B7A13
32 inputs
(See Note 2)
2 words for
input
0.07 A min.
CQM1-B7Ajj
)
g
CQM1-B7A03
32 outputs
2 words for
output
0.10 A min.
p
(
) y
CQM1H
CQM1-B7A12
16 inputs
(See Note 1)
1 word for
input
0.05 A min.
,
CQM1-B7A02
16 outputs
1 word for
output
0.04 A min.
A--199