XG4S-1004 Omron, XG4S-1004 Datasheet

CONN STRAIN RLF 10POS FOR GX4E

XG4S-1004

Manufacturer Part Number
XG4S-1004
Description
CONN STRAIN RLF 10POS FOR GX4E
Manufacturer
Omron
Series
XG4r
Datasheet

Specifications of XG4S-1004

Accessory Type
Strain Relief
Number Of Positions
10
Product Type
Accessories
Number Of Positions / Contacts
10
Housing Material
Polyamide
Pitch
2.54 mm
Number Of Rows
2
Row Spacing
2.54 mm
No. Of Positions
10
Strain Relief Material
Polyamide Resin
No. Of Contacts
10
For Use With
XG4E-1072 - CONN PLUG 10POS FLAT CABLE IDCXG4E-1071 - CONN PLUG 10POS FLAT CABLE IDCXG4E-1032 - CONN PLUG 10POS FLAT CABLE IDCOR999 - CONN PLUG 10POS 1A OPENEND COVER
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
XG4 Series
Features
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
OR927
XG4S1004
XG4S1004
Industry Standard Circuit Board
Connectors Conform to MIL Standards
• XG4M-U: Unique locking system, with lock levers on strain
• Space-saving Box-type Plugs (XG4C) available.
• Can be used with XG5 IDC Connectors for discrete wires, XG8
• The Original Plugs (XG8) and the Box-type Plugs (XG4C)
• Conforms to MIL standards (MIL-C-83503).
• UL recognition (file No. E103202)
Ordering Information
Note: 1. XG4M can be provided with or without the strain reliefs;
■ Ratings and Characteristics
Rated current
Rated voltage
Contact resistance
Insulation resistance
Dielectric strength
Connector insertion
Contact removal
Insertion durability
Ambient temperature
relief / socket instead of on plug, saves 24% of space
Original PCB Plugs, and the XG2 IDC Bus Connectors for PCBs.
can be locked using External XG5Z and XG4Z Lock Levers.
Flat Cable Connectors
XG4
Appearance
Strain relief
Connector
Feature
2. XG4H PCB mount socket mates with XG4C and XG8W (see XG8 Datasheet) for board to board connectivity without cables.
3. XG5 connectors (see XG5 Datasheet) use discrete wire instead of flat ribbon cable.
4. XG4A PCB mount sockets are available with Long, Short or no Lock Levers.
5. Optional XG4Z-001@ side-lock levers, purchased separately, are available for use with right-angle XG4A versions that don’t include them.
6. Optional XG4Z-0002 and XG5Z-0002 top-lock levers are available for mating XG4M(-T) sockets to XG4C and XG8 plugs.
⇒ XG4M-U consists of XG4M-@@3@ socket +XG4U-@@04 strain relief
⇒ XG4M-T consists of XG4M-@@3@ socket + XG4T-@@04 strain relief
Item
with lock levers
Strain relief
XG4U
1 A
250 VAC
20 mΩ max. (at 20 mV, 100 mA max.)
1,000 MΩ min. (at 500 VDC)
500 VAC for 1 min (leakage current: 1 mA max.)
1.96 N max. per contact
0.39 N min. (with test gauge, t= 0.64 mm)
50 times (See note 2.)
Operating: –55 to 105°C (with no icing)
Socket
XG4M
MIL Sockets: XG4M
Cable Plug: XG4E
without lock levers
Strain relief
Cable
XG4T
Lock levers on
connector
XG4E
XG4S
3 A (See note 1.)
300 VAC
Plug
Board to Board Sockets: XG4H
Box-type PCB Plugs: XG4C
MIL Plugs: XG4A
lock levers
Integral
XG4A
- - -
with lock levers
Flat Cable Connectors
XG4A
Plug
2-tier
- - -
Note: 1. The rated current will depend on the
2. For standard 0.15-μm gold plating.
PCB
Socket you are using. It is 1 A using
the XG4M for example.
Box type plug
XG4C
- - -
XG4
Board to Board
Socket
Socket
XG4H
- - -
41

Related parts for XG4S-1004

XG4S-1004 Summary of contents

Page 1

... N min. (with test gauge, t= 0.64 mm) Insertion durability 50 times (See note 2.) Ambient temperature Operating: –55 to 105°C (with no icing) Plug Plug XG4E XG4A XG4A XG4S - - - - - - Lock levers on Integral 2-tier connector lock levers with lock levers MIL Plugs: XG4A Box-type PCB Plugs: XG4C Board to Board Sockets: XG4H 3 A (See note 1 ...

Page 2

... XG4U Strain Relief with Locks) Mates with XG4 42 Flat Cable Connectors Cable Plugs: XG4E MIL Sockets: XG4M (Strain Relief: XG4S) (Strain Relief: XG4T) Polyamide resin (UL94V-0)/ Fiber-glass reinforced PBT black resin (UL94V-0)/black Phosphor bronze/nickel base, 0.15-μm gold plating (See note.) Polyamide resin (UL94V-0)/ ...

Page 3

Mating Diagrams for XG4M XG4U + XG4M + XG4C (With straight terminals) XG4U 20.2 XG4C XG4M XG4U + XG4M + XG4C (With right-angle terminals) XG4U 20.2 9.3 XG4C XG4M XG4T + XG4M + XG4A XG4T XG4M 23.5 XG4A XG4T + ...

Page 4

Cable Mount Connectors ■ XG4M-U Sockets (Uses XG4U Strain Relief with Lock Levers) Dimensions XG4U-@@04 Strain Reliefs with Locks A B 3.3 (Locked 3.3 (Unlocked) 1 XG4M-@@30 (one polarity guide) XG4M-@@31 (all others) Open-end cover Triangular mark Polarity ...

Page 5

XG4M-T Sockets (Uses XG4T Strain Relief without Lock Levers) Dimensions XG4M-@@30 (one polarizing guide) XG4M-@@31 (all others) Triangular mark XG4T-@@04 Strain Relief Ordering Information No. of No. of Socket+Strain Relief Set (See notes 1 and 2.) Socket with Open-end ...

Page 6

... XG4E Plugs and XG4S Strain Relief Dimensions XG4E-@@31/-@@71 (With long locks) (Long locks) XG4E-@@32/-@@72 (With short locks) 0.635 × 0.635 XG4S-@@04 Strain Relief XG4 46 Flat Cable Connectors (Locking Levers on Connector) Open-end cover Strain Relief Two, 2.6 dia. (M3 tapping screw hole) ...

Page 7

... XG4E-6432 XG4E-6472 Socket (mated side) Triangular mark Cable mark Cable No. Plug (XG4E) Triangular mark Cable mark Cable No. Flat Cable Connectors Strain Reliefs for XG4E XG4S-1004 XG4S-1404 XG4S-1604 XG4S-2004 XG4S-2604 XG4S-3004 XG4S-3404 XG4S-4004 XG4S-5004 XG4S-6004 XG4S-6404 Right-angle Terminal Plug (terminal side) XG4A XG4C ...

Page 8

PCB Mount Connectors ■ XG4A Plugs with Long Lock levers Dimensions XG4A-@@31/-@@71 (With straight DIP terminals) XG4A-@@34/-@@74 (With right-angle DIP terminals) Straight DIP terminals Right-angle DIP terminals Polarity slot Polarizing Key slot Polarizing Key slot (not on models with less ...

Page 9

Ordering Information Use in Combination with XG4M-T cable mount Sockets with strain relief or XG5M Sockets for discrete wire. No. of No. of Plugs with straight DIP terminals contacts polarizing slots 10 0 XG4A-1071 1 XG4A-1031 14 1 XG4A-1431 16 ...

Page 10

XG4A Plugs with Short Locks Dimensions XG4A-@@32/-@@72 (With straight DIP terminals) XG4A-@@35/-@@75 (With right-angle DIP terminals) Straight DIP terminals Right-angle DIP terminals Triangular Polarity slot mark Polarizing Key slot Polarizing Key slot (not on models with less than 14 ...

Page 11

Ordering Information Use in Combination with XG4M cable mount Sockets without strain relief. No. of No. of Plugs with straight DIP terminals contacts polarizing slots 10 0 XG4A-1072 1 XG4A-1032 14 1 XG4A-1432 16 1 XG4A-1632 20 1 XG4A-2032 26 ...

Page 12

XG4A Plugs without Lock Levers Note: XG4Z-001@ Lock Levers that can be installed after PCB assembly may be purchased separately. (See the following page.) Dimensions XG4A-@@33/-@@73 (With straight DIP terminals) XG4A-@@36/-@@76 (With right-angle DIP terminals) Straight DIP terminals Right-angle ...

Page 13

Ordering Information No. of No. of Plugs with straight DIP terminals contacts polarizing slots 10 0 XG4A-1073 1 XG4A-1033 14 1 XG4A-1433 16 1 XG4A-1633 20 1 XG4A-2033 26 1 XG4A-2633 30 1 XG4A-3033 34 1 XG4A-3433 40 1 XG4A-4033 ...

Page 14

XG4A 2-tier Plugs with Long Lock Lever Dimensions XG4A-@@39-A/-@@79-A (With long locks and right-angle DIP terminals) No. of Dimensions (mm) contacts × 2 32.0 17.5 10.16 21.8 46.4 14 × 2 37.1 22.6 ...

Page 15

Mounting Example Applicable Mating Sockets No. of contacts No. of polarity slots 2-tier Plug Model No. 10 × XG4A-1079-A XG4M-1031 1 XG4A-1039-A XG4M-1030 14 × XG4A-1439-A XG4M-1430 16 × XG4A-1639-A XG4M-1630 20 × 2 ...

Page 16

XG4C Box-type (Shrouded) Plugs Note: See XG8 Datasheet for unshrouded PCB plugs / headers that mate with the XG4M-T cable mount sockets. Dimensions XG4C-@@31/-@@71 (With straight DIP terminals) Triangular mark XG4C-@@34/-@@74 (With right-angle DIP terminals) (Straight DIP terminals) Ordering ...

Page 17

XG4H Board-to-Board Sockets Dimensions XG4H-@@31/-@@71 (With straight DIP terminals) 6.1 3.8 Polarizing Key slot 2.45 (Not on models with Polarizing Key slot less than 14 contacts.) (Not on models with less than 10 Polarity guide Triangular contacts.) 3 mark ...

Page 18

Mating Diagrams for XG4H Plug Socket XG4H-@@31/-@@71 (With straight DIP 2.54 terminals) XG8W XG4H 2.54 Stacking XG4H-4034 (With right-angle DIP XG8W terminals) 15.23 6.82 0.52 Horizontal (forward direction) XG4 58 Flat Cable Connectors XG8W Original Plugs (See XG8 Datasheet) ...

Page 19

Polarity Slot and Polarizing Key Slot Number and Position Classification 10 contacts XG4M XG4M-1031 Cable Socket XG4A XG4A-107@ PCB Plug XG4E Cable Plug XG4E-107@ XG4C XG4C-107@ Box-type PCB Plug No. of polarizing 0 guides (Polarizing Slots) No. of Polarizing 1 ...

Page 20

Tools and Accessories (Sold Separately) See “XG@ - Assembly Tooling and Accessories” datasheet from additional information about cable termination tooling. ■ External Polarization Options The following optional accessories can be used to provide polarization to sockets and plugs that do ...

Page 21

MEMO XG4 Flat Cable Connectors ...

Page 22

... All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ELECTRONIC COMPONENTS LLC 55 E. Commerce Drive, Suite B ...

Related keywords