XCS-A502 TELEMECANIQUE, XCS-A502 Datasheet - Page 4

SAFETY SWITCH, 2NO/1NC

XCS-A502

Manufacturer Part Number
XCS-A502
Description
SAFETY SWITCH, 2NO/1NC
Manufacturer
TELEMECANIQUE
Datasheet

Specifications of XCS-A502

Contact Voltage Ac Max
250V
Contact Voltage Dc Max
24V
Contact Current Ac Max
6A
Contact Current Dc Max
540mA
Switch Terminals
Screw
Approval Bodies
EN1088, EN60204, EN60947-5-1
Conduit Thread Size
M20 X
Dimensions :
pages 2/23 and 2/24
Schemes :
pages 2/25 to 2/27
Type of switch
Type of interlocking
LED indication
Supply voltage of solenoid
References of switches without actuator
3-pole N/C + N/O + N/O
(2 N/O staggered)
slow break (4)
3-pole N/C + N/C + N/O
(N/O staggered)
slow break (4)
3-pole N/C + N/C + N/C
slow break (4)
Weight (kg)
Solenoid characteristics
Load factor
Rated operational voltage
Voltage limits
Service life
Consumption
LED indicator characteristics
Rated insulation voltage
Current consumption
Rated operational voltage
Voltage limits
Service life
Protection against overvoltages
(1) Adjustable throughout 360 in 90 steps.
allowing key withdrawal and subsequent opening of the N/C safety contacts.
(3) For use on a 110/120 V or a 220/240 V, remove the LED indicator module.
(4) Schematic diagrams shown represent the contact states whilst the actuator is inserted in the head of the switch.
(5) Units supplied with a single green LED.
Components for safety applications
Guard switches
Metal, turret head
Cable entries tapped M20 x 1.5
References, characteristics
With interlocking, locking by solenoid
Locking on de-energisation and unlocking on energisation of solenoid (2).
To order a limit switch with locking on energisation and unlocking on de-energisation of the solenoid, replace the 2
number (3) by 5 in the references shown below.
Example : XCS-E5312 becomes XCS-E5512.
Orange LED : “guard open” signalling.
Green LED : “guard closed and locked” signalling.
c or a 24 V
(50/60 Hz on c)
XCS-E5312
XCS-E7312
XCS-E8312 (5)
1.140
100 %
c
c c
c c or a a a a a 24 V
- 20 %, + 10 % of the rated operational voltage (including ripple on a) conforming to IEC 947-1
20,000 hours
Inrush : 10 VA. Sealed : 10 VA
50 V conforming to IEC 947-1
7 mA
c c
c c or a a a a a 24/48 V
c
c or a 20...52 V (including ripple on a)
100,000 hours
Yes
(2) A key operated lock enables the forced opening of the interlocking mechanism by authorised personnel,
(
N/C contact with positive opening operation)
(1)
, types XCS-A, XCS-C and XCS-E
XCS-E5322
XCS-E7322
1.140
c c
c c or a a a a a 48 V
c or a 48 V
(50/60 Hz on c)
XCS-E8322 (5)
c
c or a 110/120 V (3)
(50/60 Hz on c)
XCS-E5332
XCS-E7332
XCS-E8332 (5)
1.140
c
c c
c c or a a a a a 110/120 V
250 V conforming to IEC 947-1
7 mA
c c
c c 110/240 V
c
c 95...264 V (including ripple on a)
100,000 hours
Yes
c or a 220/240 V (3)
(50/60 Hz on c)
XCS-E5342
XCS-E7342
XCS-E8342 (5)
1.140
c
c c
c c or a a a a a 220/240 V
Te
2/17
nd
2

Related parts for XCS-A502