E5EK-AA2-DRT-500 AC100-240 Omron, E5EK-AA2-DRT-500 AC100-240 Datasheet

no-image

E5EK-AA2-DRT-500 AC100-240

Manufacturer Part Number
E5EK-AA2-DRT-500 AC100-240
Description
PROCESS CONTROLLER
Manufacturer
Omron
Series
E5EKr
Type
Digital Controllerr

Specifications of E5EK-AA2-DRT-500 AC100-240

Input Type
Current, Voltage, RTD, Thermocouple (Multiple)
Controller Type
On/Off
Temperature Range
Selectable, Varies By Input Type
Output Type
Output Units Available
Supply Voltage
100 ~ 240VAC
Size
48mm W x 96mm H (1/8 DIN)
Features
Burnout Detection, Terminal Cover
Communications
DeviceNet
Display Type
4 Digit (2), LEDs
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E5EK-AA2-DRT-500AC100-240
E5EKAA2DRT500AC100240
Unit Descriptions
A Digital Controller That Conforms to
DeviceNet
• Conforms to DeviceNet, thus communicates with Programma-
• High-performance range of 0.1% FS (Pt input: −100.0°C to
• Configurator (sold separately) ensures easy initial settings.
Ordering Information
Note: 1. The heater burnout alarm will be available if the ON/OFF Output Unit is applied to heat control.
Control Output Unit (Sold Separately)
Note: The E53-S has no zero-cross function.
Note: Use the High-resolution Output Unit for the E5EK-AA2-DRT. The E53-C Current Output Unit for E5@X cannot be used.
Terminal Cover
Current Transformer (CT)
(Sold Separately)
Note: Be sure to order the CT along with the Control Output Unit if the
E5EK
48 x 96 mm
Model
Applicable model
Hole dia.
176
ble Controllers with no program required.
100.0°C)
Digital Controller
E5EK-AA2-DRT
Model
Item
2. If using both control outputs 1 and 2, two Control Output Units are required.
3. A CT is not provided with the E5EK-AA2-DRT. If using the heater burnout alarm, be sure to order the E5EK-AA2-DRT together with the
heater burnout alarm of the E5EK-DRT is required.
Model
CT.
E53-R
5.8 dia.
Relay
Size
E54-CT1
E5EK
E53-S
(See note.)
SSR
E53-COV08
12.0 dia.
E53-Q
ON/OFF
DeviceNet (CompoBus/D)
E54-CT3
E53-Q3
Voltage
Communication
E53-Q4
Models with Test Result Sheet
If a test result sheet is required for the model, place the order in the
following way.
Model Number
Order using the following example.
E5EK-AA2-DRT-K
Add a hyphen and the suffix “K” to the end of the model number.
E53-C3
E5EK-AA2-DRT
Current
E53-C3D
Linear
E53-V34
Model
Digital Controller
E5EK-AA2-DRT
Voltage
E53-V35

Related parts for E5EK-AA2-DRT-500 AC100-240

E5EK-AA2-DRT-500 AC100-240 Summary of contents

Page 1

... Note: 1. The heater burnout alarm will be available if the ON/OFF Output Unit is applied to heat control using both control outputs 1 and 2, two Control Output Units are required not provided with the E5EK-AA2-DRT. If using the heater burnout alarm, be sure to order the E5EK-AA2-DRT together with the CT. ...

Page 2

... equivalent noise filter to the AC power line. 2. There is a model with 100 to 240 VAC specifications and a model with 24 VAC/VDC specifications. Unless the required model is specified, the model with 100 to 240 VAC specifications will be ordered. 3. The E5EK-AA2-DRT is not equipped with a fuzzy self-tuning function. Thermocouple T ...

Page 3

... VAC for 1 min Vibration resistance 50 Hz with 98 m/s Weight E54-CT1: Approx. 11.5 g E54-CT3: Approx Accessories (only E54-CT3) Armature (2), plug (2) 178 and Z directions for 10 min times each and Z directions times each and Z directions NEMA4 for indoor use (conforming to IP66) IP20 Rating/specification 2 Digital Controller E5EK-AA2-DRT ...

Page 4

... Note: This product has been tested at the test laboratory of a third-party organization authorized by the ODVA and has been certified to conform to the ODVA’s conformance software versions 2.0 to 1.00. For details on Object specifications, refer to the E5EK Digital Controller User’s Manual (H085). ...

Page 5

... E5EK-AA2-DRT Precautions For details on precautions and other information required to use this product, be sure to refer to the following manuals: E5EK Digital Controller User’s Manual (H085) and DeviceNet Operation Manual (W267). These manuals are not provided with this product. They must be obtained sepa- rately ...