E53-CNH01N2 Omron, E53-CNH01N2 Datasheet - Page 9

no-image

E53-CNH01N2

Manufacturer Part Number
E53-CNH01N2
Description
CARD OPTION RS232C+HB ALARM
Manufacturer
Omron
Datasheet

Specifications of E53-CNH01N2

Accessory Type
Heater Burnout/SSR Failure/Heater Overcurrent/RS-232C
Svhc
No SVHC (15-Dec-2010)
Signal Input Type
Event
For Use With
E5CN-H Controller
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
External Connections
Controllers
Note: Wire all voltage input terminals correctly. The Controller may fail if voltage input terminals are wired incorrectly.
Control output 2
12 VDC 21 mA
Option Units
• A voltage output (control output, for driving SSR) is not electrically insulated from the internal circuits. When using a grounding thermocouple,
Relay output
Voltage output
Linear voltage output
0 to 10 VAC
Load 1 kΩ max.
Current output
do not connect any of the control output terminals to ground. If the control output terminals are connected to ground, errors will occur in the
measured temperature values as a result of leakage current.
250 VAC, 3 A
(resistive load)
(for driving SSR)
12 VDC, 21 mA
0 to 20 mA DC
4 to 20 mA DC
Load 600 Ω max.
CT2
Control output 1
EV2
DO NOT
USE
DO NOT
USE
DO NOT
USE
DO NOT
USE
DO NOT
USE
RS-485
E53-CNQHHN2
Control Output 2
and CT2
E53-CN03N2
Communications
(RS-485)
EV1
CT1
A (−)
B (+)
E53-CNBN2
Event Inputs
11
12
13
14
15
11
12
13
14
15
11
12
13
14
15
mA
Control output 2
12 VDC 21 mA
Control output 2
12 VDC 21 mA
Control output 2
12 VDC 21 mA
DON’T
USE
Transfer output
mA
E53-CNQ03N2
Communications (RS-485)
and Control Output 2
EV2
E53-CNQFN2
Control Output 2 and
Transfer Output
DO NOT
USE
DO NOT
USE
RS-485
E53-CNQBN2
Event Inputs and
Control Output 2
DON’T
USE
EV1
A (−)
B (+)
V
V
11
12
13
14
15
11
12
13
14
15
11
12
13
14
15
Control output 1
4 to 20 mA DC
(Load 600 Ω
max.)
DON’T
USE
t/c
Pt
A
B
B
CT1
CT1
Advanced Digital Temperature Controller
EV2
DO NOT
USE
DO NOT
USE
DO NOT
USE
1
2
3
4
5
RS-485
RS-232C
E53-CN01N2
Communications
(RS-232)
E53-CNH03N2
Communications
(RS-485) and CT
EV1
A (−)
B (+)
SD
RD
SG
E53-CNHBN2
Event Inputs
and CT
11
12
13
14
15
11
12
13
14
15
11
12
13
14
15
11
12
13
14
15
10
Transfer output
6
7
8
9
CT2
CT1
EV2
Auxiliary outputs
(relay outputs)
250 VAC, 3 A
(resistive load)
Auxiliary output 1
RS-485
RS-232C
Input power supply
E53-CNHH03N2
Communications
(RS-485) and CT2
E53-CNH01N2
Communications
(RS-232) and CT
Auxiliary output 2
E53-CNBFN2
Event Inputs and
Transfer Output
EV1
CT1
?
A (−)
B (+)
SD
RD
SG
11
12
13
14
15
11
12
13
14
15
11
12
13
14
15
4 to 20 mA DC
(Load 600 Ω max.)
• 100 to 240 VAC
• 24 VAC/VDC (no polarity)
A heater burnout alarm, SSR
failure, heater overcurrent alarm,
or input alarm is sent to the
output to which the alarm 1
function is assigned.
Control output 2
12 VDC 21 mA
Control output 2
12 VDC 21 mA
E5CN-H
E53-CNQ01N2
Communications (RS-232)
and Control Output 2
DO NOT
USE
RS-232C
E53-CNQHN2
Control Output 2
and CT
CT1
SD
RD
SG
11
12
13
14
15
11
12
13
14
15
9

Related parts for E53-CNH01N2