E53-CNBN2 Omron, E53-CNBN2 Datasheet

Controller Option Unit

E53-CNBN2

Manufacturer Part Number
E53-CNBN2
Description
Controller Option Unit
Manufacturer
Omron
Datasheet

Specifications of E53-CNBN2

Operating Temperature Max
55°C
Operating Temperature Min
-10°C
Temperature Accuracy ±
0.3%
Mounting Type
DIN Panel
Approval Bodies
CULus, CE
For Use With
E5CN Temperature Controller
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
New 48 x 48-mm Basic Temperature
Controller with Enhanced Functions and
Performance. Improved Indication
Accuracy and Preventive Maintenance
Function.
Main I/O Functions
• Indication Accuracy
• New E5CN-U Models (Plug-in Models) with analog inputs and
• A PV/SV-status display function can be set to automatically
• Preventive maintenance for relays in the Temperature Controller
Sensor Inputs
• Universal thermocouple/Pt inputs
• Analog current/voltage inputs
Indication Accuracy
• Thermocouple input: ±0.3% of PV
• Pt input: ±0.2% of PV
• Analog input: ±0.2% FS
Sampling Period
• 250 ms
Basic-type Digital Temperature Controller
E5CN/E5CN-U
Thermocouple input: ±0.3% of PV (previous models: ±0.5%)
Pt input: ±0.2% of PV (previous models: ±0.5%)
Analog input: ±0.2% FS (previous models: ±0.5%)
current outputs.
alternate between displaying the status of the Temperature
Controller (auto/manual, RUN/STOP, and alarms) and the PV or SV.
using a Control Output ON/OFF Counter.
This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions
and other information required for operation before attempting to use the product.
E5CN/E5AN/E5EN/E5GN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H156)
E5CN/E5AN/E5EN/E5GN Digital Temperature Controllers Communications Manual Basic Type (Cat. No. H158)
(Models with temperature inputs)
(Models with analog inputs)
Event Inputs
• None
• Two
Control Output 1
• Relay output
• Voltage output (for driving SSR)
• Current output
• Long-life relay output (hybrid)
E5CN
Control Output 2
• None
• Voltage output
(for driving SSR)
2-level Display: PV and SV
Auxiliary Outputs
• None
• One
• Two
(48 x 48 mm)
Refer to Operation for E5
procedures.
Refer to Safety Precautions for E5
48 × 48-mm
E5CN
4-digit Display
• Auto/manual switching
• Temperature Controller status display
• Simple program function
• Control output ON/OFF count alarm
• PV change rate alarm
• Models also available with RS-485
communications
CSM_E5CN_E5CN-U_DS_E_5_1
@
N/E5
@
48 × 48-mm
N-H for operating
E5CN-U
@
N/E5
@
N-H.
1

Related parts for E53-CNBN2

E53-CNBN2 Summary of contents

Page 1

Basic-type Digital Temperature Controller E5CN/E5CN-U New 48 x 48-mm Basic Temperature Controller with Enhanced Functions and Performance. Improved Indication Accuracy and Preventive Maintenance Function. • Indication Accuracy Thermocouple input: ±0. (previous models: ±0.5%) Pt input: ±0. ...

Page 2

... Terminal Cover -500: With terminal cover Note: 1. Not all combinations of function 1 and function 2 specifications are possible for Option Units (E53-@@@@). 2. Estimates can be provided for coatings and other specifications that are not given in the datasheet. Ask your OMRON representative for details. *1. Always connect an AC load to a long-life relay output. The output will not turn OFF load is connected because a triac is used for switching the circuit ...

Page 3

... E5CN-C2MLD-500 E5CN-RMT-W-500 E5CN-QMT-W-500 E5CN-CMT-W-500 E5CN-R2MT-W-500 E5CN-Q2MT-W-500 E5CN-C2MT-W-500 E5CN-Y2MT-W-500 E5CN-R2MTD-W-500 E5CN-Q2MTD-W-500 E5CN-C2MTD-W-500 Model (See Note 2.) E53-CNHH03N2 E53-CNHBN2 E53-CNQ03N2 External power supply for E53-CNPBN2 ES1B External power supply for E53-CNPHN2 ES1B External power supply for E53-CNP03N2 ES1B E53-CNH03N2 E53-CN03N2 E53-CNBN2 E53-CNQHN2 E53-CNQHHN2 E53-CNQBN2 3 ...

Page 4

Model Number Structure Model Number Legend (Plug-in-type Controllers) E5CN-@@@ Output Type R: Relay output Q: Voltage output (for driving SSR) C: Current output 2. Number of Alarms Blank: No alarm 1: One alarm 2: Two ...

Page 5

... Connectable models Terminal block models Note: Use this Adapter when the panel has been previously prepared for the E5B@. Model Sockets (for Plug-in Models) E53-COV17 Front-connecting Socket Front-connecting Socket with Finger Protection Back-connecting Socket Terminal Cover for Back-connecting socket with Finger Protection ...

Page 6

Specifications Ratings model number: 100 to 240 VAC, 50/60 Hz Power supply voltage D in model number: 24 VAC, 50/60 Hz; 24 VDC Operating voltage range 85% to 110% of rated supply voltage 100 to 240 VAC: ...

Page 7

Input Ranges Thermocouple/Platinum Resistance Thermometer (Universal Inputs) Input Platinum resistance Type thermometer Name Pt100 JPt100 K 2300 1800 1700 1600 1500 1400 1300 1300 1200 1100 1000 850 900 800 700 600 500.0 500.0 500.0 500 400 300 200 100.0 ...

Page 8

Alarm Outputs Each alarm can be independently set to one of the following 13 alarm types. The default is 2: Upper limit. Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be ...

Page 9

... When robust tuning (RT) is ON, the differential time is 0.0 to 999.9 (in units of 0.1 s). *6. External communications (RS-485) and cable communications for the Setup Tool can be used at the same time. *7. The E5CN-U plug-in model is certified for UL listing only when used together with the OMRON P2CF-11 or P2CF-11-E Socket. The P3GA-11 is not certified for UL listing. ...

Page 10

USB-Serial Conversion Cable Applicable OS Windows 2000, XP, or Vista Applicable software CX-Thermo version 4 or higher E5AN/E5EN/E5CN/E5CN-U/E5AN-H/ Applicable models E5EN-H/E5CN-H/E5GN USB interface standard Conforms to USB Specification 1.1. DTE speed 38400 bps Computer: USB (type A plug) Connector Temperature ...

Page 11

... Control Output 2 B(+) 11 11 RS-485 12 EV1 12 A(− NOT 13 EV2 USE + External VDC, 14 power supply 20 mA Control output 2 15 − 15 − E53-CNBN2 E53-CNQHN2 Event inputs Control Output 2 and Control output 2 − EV1 DO NOT 13 13 EV2 USE DO NOT 14 14 USE CT1 DO NOT 15 15 USE ...

Page 12

... Temperature unit Level Key Mode Key Down Key 1.5 44.8 × 44.8 48.8 60 min. Mounting Adapter Terminal Cover (Accessory) (E53-COV17) (Accessory) Note: The terminal block cannot be removed. (84.7) 14.2 6 70.5 44.8 × 44.8 60 min. Mounting Adapter (Accessory) LED indicator (SD) 250 USB connector (type A plug) E5CN/E5CN-U No ...

Page 13

... Terminal Cover E53-COV17 Note: The E53-COV10 cannot be used. 48 48.8 22 9.1 Current Transformers E54-CT1 E54-CT3 40 × E54-CT3 Accessory • Armature Connection Example Plug Approx. 3 dia. 18 • Plug Approx. 6 dia. (22) Waterproof Packing Y92S-29 (for DIN 48 × 48) Order the Waterproof Packing separately if it becomes lost or damaged ...

Page 14

Adapter Y92F-45 Note: 1. Note: 1. Use this Adapter when the panel has already been prepared for the E5B@. 2. The Adapter is available only in black. Mounted to E5CN E5CN-U Wiring Socket Front-connecting Socket Eleven, M3.5 × 7.5 P2CF-11 ...

Page 15

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords