APDS-9003-020 Avago Technologies US Inc., APDS-9003-020 Datasheet - Page 8

AMBIENT LIGHT SENSOR 6CHIPLED

APDS-9003-020

Manufacturer Part Number
APDS-9003-020
Description
AMBIENT LIGHT SENSOR 6CHIPLED
Manufacturer
Avago Technologies US Inc.
Type
Ambient Light Photo Sensorr
Datasheet

Specifications of APDS-9003-020

Peak Wavelength
620 nm
Maximum Light Current
370 uA
Maximum Dark Current
160 nA
Maximum Rise Time
2 ms
Maximum Fall Time
2 ms
Package / Case
Chip LED-6
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Product
Ambient Light Sensor
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
516-1715-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
APDS-9003-020
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Recommended Reflow Profile
The reflow profile is a straight-line representation of a
nominal temperature profile for a convective reflow solder
process. The temperature profile is divided into four
process zones, each with different DT/Dtime temperature
change rates. The DT/Dtime rates are detailed in the
above table. The temperatures are measured at the
component to printed circuit board connections.
In process zone P1, the PC board and APDS-9003
castellation pins are heated to a temperature of 160°C to
activate the flux in the solder paste. The temperature
ramp up rate, R1, is limited to 4°C per second to allow for
even heating of both the PC board and APDS-9003
castellations.
Process zone P2 should be of sufficient time duration
(60 to 120 seconds) to dry the solder paste. The
temperature is raised to a level just below the liquidus
point of the solder, usually 200°C (392°F).
8
Heat Up
Cool Down
Solder Paste Dry
Solder Reflow
Process Zone
160
120
255
230
220
200
180
25
80
0
HEAT
R1
P1
UP
Symbol
P2, R2
P3, R3
P3, R4
P4, R5
P1, R1
50
SOLDER PASTE DRY
R2
200°C to 255°C (260°C at 10 seconds max)
P2
100
160°C to 200°C
255°C to 200°C
25°C to 160°C
200°C to 25°C
Process zone P3 is the solder reflow zone. In zone P3, the
temperature is quickly raised above the liquidus point of
solder to 255°C (491°F) for optimum results. The dwell
time above the liquidus point of solder should be between
20 and 60 seconds. It usually takes about 20 seconds to
assure proper coalescing of the solder balls into liquid
solder and the formation of good solder connections.
Beyond a dwell time of 60 seconds, the intermetallic
growth within the solder connections becomes excessive,
resulting in the formation of weak and unreliable
connections. The temperature is then rapidly reduced to
a point below the solidus temperature of the solder,
usually 200°C (392°F), to allow the solder within the
connections to freeze solid.
Process zone P4 is the cool down after solder freeze. The
cool down rate, R5, from the liquidus point of the solder
to 25°C (77°F) should not exceed 6°C per second
maximum. This limitation is necessary to allow the PC
board and APDS-9003 castellations to change dimensions
evenly, putting minimal stresses on the APDS-9003.
150
T
R3
Above 220 C
MAX 260C
REFLOW
SOLDER
60 sec
MAX
P3
200
R4
COOL DOWN
Maximum T/ time
0.5°C/s
4°C/s
4°C/s
-6°C/s
-6°C/s
P4
R5
250
t-TIME
(SECONDS)
300

Related parts for APDS-9003-020