ADIS16265BCCZ Analog Devices Inc, ADIS16265BCCZ Datasheet - Page 17

IC SENSOR GYRO PROGR 10MV 20LGA

ADIS16265BCCZ

Manufacturer Part Number
ADIS16265BCCZ
Description
IC SENSOR GYRO PROGR 10MV 20LGA
Manufacturer
Analog Devices Inc
Series
MEMSr
Datasheet

Specifications of ADIS16265BCCZ

Range °/s
±80°/s, ±160°/s, ±320°/s
Sensitivity
±0.2%
Typical Bandwidth
50Hz
Voltage - Supply
4.75 V ~ 5.25 V
Current - Supply
41mA
Output Type
Digital
Operating Temperature
-40°C ~ 105°C
Package / Case
20-LGA
No. Of Axes
1
Sensor Case Style
LGA
No. Of Pins
20
Supply Voltage Range
4.75V To 5.25V
Operating Temperature Range
-40°C To +105°C
Msl
MSL 5 - 48 Hours
Termination Type
SMD
Acceleration Range
2000g
Filter Terminals
SMD
Digital Ic Case Style
LGA
Lead Free Status / RoHS Status
Lead free / RoHS compliant by exemption

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADIS16265BCCZ
Manufacturer:
TOSHIBA
Quantity:
928
Table 28. ALM_CTRL Bit Descriptions
Bits
[15]
[14:12]
[11]
[10:8]
[7:5]
[4]
[3]
[2]
[1]
[0]
Table 29. Alarm Configuration Example 1
DIN
0xA922,
0xA817
0xA181,
0xA000
0xA33F,
0xA200
Description (Default = 0x0000)
Rate-of-change enable for Alarm 2
(1 = rate of change, 0 = static level).
Alarm 2 source selection.
000 = disable.
001 = power supply output.
010 = gyroscope output.
011 = not used.
100 = not used.
101 = auxiliary ADC input.
110 = temperature output.
111 = not used.
Rate-of-change enable for Alarm 1
(1 = rate of change, 0 = static level).
Alarm 1 source selection (same as for Alarm 2).
Not used.
Comparison data filter setting
(1 = filtered data, 0 = unfiltered data).
Not used.
Alarm output enable
(1 = enabled, 0 = disabled).
Alarm output polarity
(1 = active high, 0 = active low).
Alarm output line select
(1 = DIO2, 0 = DIO1).
Description
ALM_CTRL = 0x2217.
Alarm 1 input = GYRO_OUT.
Alarm 2 input = GYRO_OUT.
Static level comparison, filtered data.
DIO2 output indicator, positive polarity.
ALM_MAG1 = 0x8100.
Alarm 1 is true if GYRO_OUT > +18.755°/sec.
ALM_MAG2 = 0x3F00.
Alarm 2 is true if GYRO_OUT < −18.755°/sec.
Rev. B | Page 17 of 20
Table 30. Alarm Configuration Example 2
DIN
0xA9AA,
0xA804
0xB601
0xA40A
0xA60A
0xA181,
0xA000
0xA30F,
0xA200
PRODUCT IDENTIFICATION
Table 31 provides a summary of the registers that identify
the product: PROD_ID, which identifies the product type;
LOT_ID1 and LOT_ID2, the 32-bit lot identification code;
and SERIAL_NUM, which displays the 16-bit serial number.
All four registers are two bytes in length.
Table 31. Identification Registers
Register Name
LOT_ID1
LOT_ID2
PROD_ID
SERIAL_NUM
Description
ALM_CTRL = 0xAA04.
Alarm 1 input = GYRO_OUT.
Alarm 2 input = GYRO_OUT.
Rate-of-change comparison, unfiltered data.
DIO1 output indicator, negative polarity.
SMPL_PRD = 0x0001.
Sample rate = 256 SPS.
ALM_SMPL1[7:0] = 0x000A.
Alarm 1 rate-of-change period = 3.906 ms.
ALM_SMPL2[7:0] = 0x000A.
Alarm 2 rate-of-change period = 3.906 ms.
ALM_MAG1 = 0x8100.
Alarm 1 is true if GYRO_OUT changes more than
18.755°/sec over a period of 3.906 ms.
ALM_MAG2 = 0x0F00.
Alarm 2 is true if GYRO_OUT changes less than
18.755°/sec over a period of 3.906 ms.
Address
0x52
0x54
0x56
0x58
ADIS16260/ADIS16265
Description
Lot Identification Code 1
Lot Identification Code 2
Product identification = 0x3F89 or
0x3F84
(0x3F89 = 16,265 decimal; 0x3F84 =
16,260 decimal)
Serial number

Related parts for ADIS16265BCCZ