D6F-V03A1 Omron, D6F-V03A1 Datasheet

AIRFLOW SENSOR 0-3 M/SEC 3.3V

D6F-V03A1

Manufacturer Part Number
D6F-V03A1
Description
AIRFLOW SENSOR 0-3 M/SEC 3.3V
Manufacturer
Omron
Series
D6Fr
Type
MEMS Air Flow Sensorr
Datasheets

Specifications of D6F-V03A1

Sensing Range
0 ~ 3 m/s
Flow Sensor Type
Air
Voltage - Input
3.15 ~ 3.45 V
Port Size
2mm x 3mm
Material - Body
Thermoplastic resin
Sensor Type
MEMS Air Flow
Rated Range
0 M/s to 3 M/s
Accuracy/reliability
+/- 10 % Full Scale
Analog Output
0 V to 2 V
Supply Voltage
3.3 V
Accuracy
± 10%
Flow Range
0 - 3 M/s
Output Type
Analog
Output Voltage Max
2V
Body Material
Thermoplastic Resin
Flow Rate Min
0GPM (US)
No. Of Ports
2
Sensor Output
Analog
Accuracy %
10%
Sensor Body Material
Thermoplastic Resin
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Switch Function/rating
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
D6FV03A1
Z2629
MEMS
flow sensors

Related parts for D6F-V03A1

D6F-V03A1 Summary of contents

Page 1

... MEMS flow sensors ...

Page 2

... The 3D MEMS structure offers outstanding characteristics in terms of resolution and repeatability even at very low flow rates. The D6F-V, D6F-W and D6F-P products incorporate a patent pending Dust Segregation System (DSS) allowing used to monitor the performance of fans and air intakes and to detect clogged filters in general. Precision performance is maintained over the product life time with an integral DSS that separates ...

Page 3

... Gas/Air Flow Flow measurement principle Inside each D6F there is a highly sensitive MEMS flow chip that is only 1.55mm x 1.55mm x 0.4mm thick. The MEMS flow chip has two thermopiles either side of a tiny heater element used to measure the deviations in heat symmetry caused by the passing gas flow in either direction. A thin layer of insulating film protects the sensor chip from exposure to the gas ...

Page 4

... Capable of highly accurate measurements over a wider temperature range compared with conventional mass flow metering, the D6F can detect mass flows with a repeatability +/- 0.1% and an accuracy +/-3% full scale deflection. The extreme sensitivity is achieved with a tiny heating element, associated with temperature sensors on both sides ...

Page 5

... Anaesthetic device CPAP Oxygen Concentrator Ozone Generator Laparoscopic Surgery Gas Chromatograph Capnograph gent Industrial Process Control Environmental Monitor/Gas Sniffer Pressurised Cable Monitoring Ventilator control Clogged filter detection Gas welding machine Pick and Place Fuel Cell Scientific Devices Gas flow controller Fans ...

Page 6

... Mass Flow Sensors D6F-P Uni-directional mass flow sensor* Flow Range 1LPM, PCB terminal type (D6F-P0010A1) 1LPM, connector type (D6F-P0010A2) Compact Size 27.2(L) x 17.2(W) x 35(H)mm Supply Voltage 4.75 – 5.25VDC Analogue Output 0.5 to 2.5V Accuracy +/- 5% F.S. Temp Range -10 to +60°C Gas Type Air * Bi-directional mass flow sensor available on request ...

Page 7

... Flow rate(L/min) D6F-01N2 / 02L2 / 05N2 High accuracy mass flow sensor Flow Range 1LPM (D6F-01N2-000), 2LPM (D6F-02L2-000), 5LPM (D6F-05N2-000) Compact Size 62 (L) x 21.6(W) x 22.1 (H)mm Supply Voltage 10.8 - 26.4VDC Analogue Output Accuracy +/- 3% F.S. Temp Range -10 to +60°C ...

Page 8

... Dust Segregation System separates up to 99.5% of dry particulates.The D6F-W01A1 and D6F-W04A1 airflow sensors can measure air velocity from 0-1m/s and 0-4m/s with an accuracy of +/-5% full scale deflection. The D6F-V03A1 measures 0-3m/s. Each is supplied as standard, optimally adjusted at the factory so easy and rapid user application is guaranteed ...

Page 9

Cassette (ceiling/suspended) Multimodular Air Conditions Duct Connected Heating and Air Conditioning Systems Alternative for Single Point Pitot tube Air & Water Air Conditioning Systems Air Purifiers/ Dehumidifiers Air Cooled, High Power Indoor Lighting Mission Critical PC, Workstation Ventilation 19” ...

Page 10

... Flow velocity(m/s) D6F-V03A1 Precision air flow detection sensor Flow Range 3m/s (D6F-V03A1) Ultra Compact Size 24(L) x 14(W) x 8(H)mm Supply Voltage 3.15 - 3.45VDC Analogue Output 0 Accuracy +/- 10% F.S. Temp Range -10 to +60°C Gas Type Air ...

Page 11

... Filter Replacement Months Omron Electronic Components Europe BV reserves the right to make any changes to the specifications of the products described in this brochure at its sole discretion and without prior notice. indicating the need for filter replacement is sent out. Threshold accumulation of dirt in the filter, and the output voltage of the sensor located on the bypass channel increases ...

Page 12

... Europe B.V. Sales Division Benelux Wegalaan 57 2132 JD Hoofddorp The Netherlands Tel: +31 23 568 1200 Fax: +31 23 568 1212 Head Office Omron Electronic Components Europe B.V. Wegalaan 57 2132 JD Hoofddorp The Netherlands Tel: +31 23 568 1200 Fax: +31 23 568 1222 Email: info-components@eu.omron.com www.omroncomponents.com Omron Electronic Components Europe B ...