D6F-CABLE2 Omron, D6F-CABLE2 Datasheet

Sensor Cable Assembly

D6F-CABLE2

Manufacturer Part Number
D6F-CABLE2
Description
Sensor Cable Assembly
Manufacturer
Omron
Type
Cable for MEMS Mass Flow Sensor D6F-03A3-000r
Datasheets

Specifications of D6F-CABLE2

Cable Length
200mm
Cable Assembly Type
Sensor
Sensor Type
Cable for MEMS Mass Flow Sensor D6F-03A3-000
Analog Output
1 V to 5 V
Supply Voltage
10.8 V to 26.4 V
Brand/series
XS5
Cable End 1, Connector Type
Plug
Ip Rating
IP 67
Length, Cable
10 m
Number Of Conductors
4
Primary Type
Cable
Accessory Type
Cable
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
D6F MASSFLOW SENSOR
For Use With
Omron D6F-03A3-000 Sensor
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Includes an MEMS Flow Element.
High-accuracy Sensing Even for Shiny
Bodies.
Note:
Ordering Information
Sensor
Cable (Order Separately)
Absolute Maximum Ratings
Performance
Note:
RoHS Compliant
0 to 3 L/min
SSH-003T-P0.2
Power supply voltage
Output voltage
Item
Flow rate
Case material
Operat-
ing con-
ditions
Power supply voltage
Output signal
Current consumption
Insulation resistance
Withstand voltage
The industry's thinnest and lightest flow sensor
(See note.), with a MEMS flow chip.
Unique flow path structure provides high precision
and fast response.
Contacts
MEMS Flow Sensor
Flow rate
According to OMRON investigation as of January 2006.
“L/min (normal)” is the volume flow rate at 0°C and 101.3 kPa.
Applicable
fluid
Operating
temperature
Operating
humidity
Storage
temperature
Storage hu-
midity
Item
AWG 28
number
Model
Wires
D6F-03A3-000
Model number
0 to 3 L/min (normal) (See note.)
Thermoplastic resin
Air (The fluid must be clean, dry gas, with no dust or oil mist.)
0 to 50°C (with no condensation or icing)
85% max. (with no condensation or icing)
−10 to 60°C (with no condensation or icing)
85% max. (with no condensation or icing)
10.8 to 26.4 VDC
Analog output: 1 to 5 VDC
Load resistance: 10 kΩ min. (non-linear output)
Without load: Vcc = 12 to 24 VDC, Vss = 0 V, 25°C, 15 mA max.
Between Sensor outer cover and lead terminals: 20 MΩ min. (at
500 VDC)
Between Sensor outer cover and lead terminals: 500 VAC, 50/
60 Hz for 1 min (leakage current: 1 mA max.)
Vcc
Vout
SHR-03V-03
Symbol
Housing
1
Minimum order
26.4
5.7
D6F-CABLE2
Model number
D6F-03A3-000
Rating
VDC
VDC
Unit
Connections
Pin No.
Connectors
Use the following connectors from J.S.T.
Mfg. Co., Ltd. to connect the D6F.
• Pressure-welded Connectors
• Crimp Connectors
1: GND
Socket:
Electric Wires: AWG 30
Contacts:
Wires:
Housing:
Enlarged view
2: Vout
D6F-03A3
1: GND
2: Vout
3: Vcc
SM03B-SRSS-TB
(Made by J.S.T. Mfg.
Co., Ltd.)
SSH-003T-P0.2
AWG32 to AGW28
SHR-03V-S-B or
SHR-03V-S
3: Vcc
03SR-3S
1

Related parts for D6F-CABLE2

D6F-CABLE2 Summary of contents

Page 1

... Withstand voltage Between Sensor outer cover and lead terminals: 500 VAC, 50 for 1 min (leakage current max.) Note: “L/min (normal)” is the volume flow rate at 0°C and 101.3 kPa. Minimum order 1 Model number D6F-CABLE2 Rating Unit 26.4 VDC 5.7 VDC D6F-03A3-000 ...

Page 2

... Cable (Order Separately) D6F-CABLE2 ± 3 ± 180 (5) ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. A181-E1-01 In the interest of product improvement, specifications are subject to change without notice. ...

Related keywords