Specifications of G3VM401BY

Load Voltage Max
400VAC
Load Current
120mA
On State Resistance Max
35ohm
Contact Configuration
SPST-NO
Isolation Voltage
5000Vrms
Forward Current If
50mA
Relay Terminals
Through Hole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
G3VM-401BY/EY
Use the G3VM under the following conditions so that the Relay will operate properly.
Load Current vs. Ambient Temperature
G3VM-401BY(EY)
Input
Output Output dielectric strength
Dielectric strength between input and
output (See note 1.)
Operating temperature
Storage temperature
Soldering temperature (10 s)
Input
Output
Capacity between I/O terminals
Insulation resistance
Turn-ON time
Turn-OFF time
Output dielectric strength
Operating LED forward current
Continuous load current
Operating temperature
Absolute Maximum Ratings (Ta = 25°C)
Electrical Characteristics (Ta = 25°C)
Recommended Operating Conditions
Engineering Data
280
240
200
160
120
80
40
0
−20
Connection A or connection B
Connection C
LED forward current
Repetitive peak LED forward
current
LED forward current reduction
rate
LED reverse voltage
Connection temperature
Continuous
load current
ON current
reduction
rate
Connection temperature
LED forward voltage
Reverse current
Capacity between terminals
Trigger LED forward current
Maximum resistance
with output ON
Current leakage when the relay is
open
0
Item
Item
Item
20
Connection A
Connection B
Connection C
Connection A
Connection B
Connection C
40
Ambient temperature (°C)
Connection A
Connection B
Connection C
60
I
I
D I
V
T
V
I
D I
T
V
T
T
---
Symbol
F
FP
O
V
I
I
T
R
j
OFF
j
I-O
a
stg
F
O
F
ON
DD
a
/°C
Symbol
80
/°C
V
I
C
I
R
I
C
R
tON
tOFF
Symbol
R
FT
LEAK
F
T
ON
I-O
I-O
50
1
-0.5
5
125
400
120
120
240
-1.2
-1.2
-2.4
125
5,000
-40 to +85
-55 to +125 °C
260
100
Rating
---
5
---
- 20
1.0
---
---
---
---
---
---
---
---
1,000
---
---
Minimum
Mini-
mum
mA
A
mA/°C
V
°C
V
mA
mA/°C
°C
Vrms
°C
°C
Unit
1.15
---
30
---
17
11
6
---
0.8
---
0.3
0.1
Typical
100 ms pulses, 100 pps
Ta ³ 25°C
Ta ³ 25°C
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
---
7.5
---
---
Measurement Conditions
Typical
1.3
10
---
3
35
20
10
1.0
---
---
1.0
1.0
Maxi-
mum
V
mA
pF
mA
W
W
W
mA
pF
MW
ms
ms
Refer to page 6 for precautions common to all G3VM models.
320
25
120
65
Unit
Maximum
Safety Precautions
I
V
V = 0, f = 1 MHz
I
I
I
I
I
I
I
V
f = 1 MHz, Vs = 0 V
V
RoH £ 60%
I
V
F
O
F
O
F
O
F
O
F
R
OFF
I-O
DD
= 10 mA
= 5 mA,
= 5 mA,
= 5 mA,
= 5 mA, R
= 120 mA
= 120 mA
= 120 mA
= 240 mA
= 5 V
= 500 VDC,
= 20 V (See note 2.)
Measurement
= 400 V
conditions
Note:
V
mA
mA
°C
L
= 200 W,
Unit
1. The dielectric strength between the input and
output was checked by applying voltage be-
tween all pins as a group on the LED side and
all pins as a group on the light-receiving side.
Connection Diagram
Connection
Connection
Connection
C
A
B
Note:
G3VM-401BY/EY
V
2. Turn-ON and Turn-OFF
I
F
OUT
I
F
1
2
Times
1
2
3
1
2
3
1
2
3
t
ON
6
5
4
6
5
4
6
5
4
10%
Load
Load
Load
or
6
4
DC
AC
DC
DC
R
L
90%
t
OFF
V
V
DD
OUT
43

Related parts for G3VM401BY