G3VM353D Omron, G3VM353D Datasheet - Page 3

SSR, MOSFET, 350V, 150mA

G3VM353D

Manufacturer Part Number
G3VM353D
Description
SSR, MOSFET, 350V, 150mA
Manufacturer
Omron
Datasheets

Specifications of G3VM353D

Load Voltage Max
350VAC
Load Current
150mA
On State Resistance Max
25ohm
Contact Configuration
SPST-NC
Isolation Voltage
2500Vrms
Forward Current If
50mA
Relay Terminals
SMD
Reverse Current (ir)
10µA
Input Type
DC
Output Type
AC/DC
Input Voltage (max)
1.3V
Output Voltage (max)
350V
Input Current (max)
50mA
Output Current
150mA
Circuit Arrangement
1 Form B
Package Type
SMT
Output Device
MOSFET
Pin Count
4
Mounting
Surface Mount
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Rad Hardened
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
G3VM Series
Common Precautions
Typical Relay Driving Circuit Examples
Use the following formula to obtain the LED current limiting resis-
tance value to assure that the relay operates accurately.
Use the following formula to obtain the LED forward voltage value
to assure that the relay releases accurately.
4
Be sure to turn OFF the power when wiring the Relay, other-
wise an electric shock may be received.
Do not touch the charged terminals of the SSR, otherwise an
electric shock may be received.
Do not apply overvoltage or overcurrent to the I/O circuits of the
SSR, otherwise the SSR may malfunction or burn.
Be sure to wire and solder the Relay under the proper soldering
conditions, otherwise the Relay in operation may generate ex-
cessive heat and the Relay may burn.
!WARNING
!WARNING
!Caution
!Caution
C-MOS
Transistor
10 to 100 kΩ
R
V
1
F (OFF)
=
V
= V
CC
5 to 20 mA
− V
CC
− V
OL
− V
OH
F
< 0.8 V
(ON)
Load
Load
Protection from Surge Voltage on the Input
Terminals
If any reversed surge voltage is imposed on the input terminals,
insert a diode in parallel to the input terminals as shown in the fol-
lowing circuit diagram and do not impose a reversed voltage value
of 3 V or more.
Surge Voltage Protection Circuit Example
Protection from Spike Voltage on the Output
Terminals
If a spike voltage exceeding the absolute maximum rated value is
generated between the output terminals, insert a C-R snubber or
clamping diode in parallel to the load as shown in the following
circuit diagram to limit the spike voltage.
Spike Voltage Protection Circuit Example
Unused Terminals (6-pin models only)
Terminal 3 is connected to the internal circuit. Do not connect
anything to terminal 3 externally.
Pin Strength for Automatic Mounting
In order to maintain the characteristics of the relay, the force
imposed on any pin of the relay for automatic mounting must not
exceed the following.
In direction A: 1.96 N
In direction B: 1.96 N
G3VM Series