D6DS TELE, D6DS Datasheet

STAR-DELTA TIMER, 2 NO

D6DS

Manufacturer Part Number
D6DS
Description
STAR-DELTA TIMER, 2 NO
Manufacturer
TELE
Datasheet

Specifications of D6DS

Contact Configuration
DPNO
Nom Input Voltage
240VAC
Delay Time Range
500ms To 3min
Adjustment Type
Knob
Relay Mounting
DIN Rail
Svhc
No SVHC (18-Jun-2010)
Coil Voltage Vac Nom
250V
Contact Current Ac
RoHS Compliant
Timers – DELTA series
Industrial design
Width 22.5mm
Star-Delta start-up
2 normally opened contacts
Technical data
1. Functions
S
2. Time ranges
Start-up time
Transit time
3. Indicators
Green LED ON:
Green LED flashes:
Yellow LED ON/OFF:
4. Mechanical design
Self-extinguishing plastic housing, IP rating IP40
Mounted on DIN-Rail TS 35 according to EN 50022
Mounting position:
Shockproof terminal connection according to VBG 4
(PZ1 required), IP rating IP20
Initial torque:
Terminal capacity:
5. Input circuit
Supply voltage:
Tolerance:
Rated frequency:
Rated consumption:
Duration of operation:
Reset time:
Residual ripple for DC:
Drop-out voltage:
Release 11/01
Time range
10s
30s
1min
3min
Time range (fixed)
40ms
60ms
80ms
100ms
Star-Delta start-up
1 x 0.5 to 2.5mm² with/without multicore cable end
1 x 4mm² without multicore cable end
2 x 0.5 to 1.5mm² with/without multicore cable end
2 x 2.5mm² flexible without multicore cable end
24V DC
24V AC
110 to 240V AC
24V DC
24V AC
110 to 240V AC
24V AC/DC
110V AC
230V AC
Adjustment range
500ms
1500ms
3s
9s
indication of supply voltage
delta-contactor in on-position
(terminals 17-28)
indication of star-time
indication of star-contactor
(terminals 17-18)
any
max. 1Nm
terminals A1(+)-A2
voltage selector engaged
terminals A1-A2
voltage selector engaged
terminals A1-A2
voltage selector not engaged
±10%
-15% to +10%
-15% to +10%
48 to 63Hz
1.5VA (1W)
2VA (1W)
8VA (1.3W)
100%
100ms
10%
>30% of the supply voltage
10s
30s
1min
3min
6. Output circuit
2 potential free normally opened contacts
Switching capacity (distance < 5mm): 1250VA (5A / 250V AC)
Switching capacity (distance > 5mm): 2000VA (8A / 250V AC)
Fusing:
Mechanical life:
Electrical life:
Switching frequency:
Insulation voltage:
Surge voltage:
7. Accuracy
Base accuracy:
Adjustment accuracy:
Repetition accuracy:
Voltage influence:
Temperature influence:
8. Ambient conditions
Ambient temperature:
Storage temperature:
Transport temperature:
Relative humidity:
Pollution degree:
9. Dimensions
8A fast acting
20 x 10
2 x 10
at 1000VA resistive load
max. 60/min at 100VA resistive load
max. 6/min at 1000VA resistive load
(according to IEC 947-5-1)
250V AC (according to IEC 664-1)
4kV, overvoltage category III
(according to IEC 664-1)
D6DS
±1% (of maximum scale value)
≤5% (of maximum scale value)
<0.5% or ±5ms
-
≤0.01% / °C
-25 to +55°C (according to IEC 68-1)
-25 to +40°C (according to UL 508)
-25 to +70°C
-25 to +70°C
15% to 85%
(according to IEC 721-3-3 class 3K3)
3 (according to IEC 664-1)
5
6
operations
operations
1.02 – 7

Related parts for D6DS

D6DS Summary of contents

Page 1

... Reset time: 100ms Residual ripple for DC: 10% Drop-out voltage: >30% of the supply voltage Release 11/01 D6DS 6. Output circuit 2 potential free normally opened contacts Switching capacity (distance < 5mm): 1250VA (5A / 250V AC) Switching capacity (distance > 5mm): 2000VA (8A / 250V AC) Fusing: 8A fast acting Mechanical life: ...

Page 2

... D6DS Functions Star-Delta start-up (S) When the supply voltage U is applied, the contact for the star- contactor switches into on-position (yellow LED illuminated) and the set star-time t1 begins (green LED flashes). After the interval t1 has expired (green LED illuminated) the contact switches into off-position (yellow LED not illuminated) and the set transit-time t2 begins ...