HIH-4000-002 Honeywell, HIH-4000-002 Datasheet - Page 8

no-image

HIH-4000-002

Manufacturer Part Number
HIH-4000-002
Description
Board Mount Humidity Sensors HUMIDITY RANGE:0-100 lead pitch SIP
Manufacturer
Honeywell
Datasheets

Specifications of HIH-4000-002

Rh Range
0 % to 100 %
Rh Accuracy
3 %
Package / Case
SIP
Output Type
Analog
Supply Voltage (max)
5.8 V
Supply Current
500 uA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
Through Hole
Accuracy
± 3.5% RH (0-100 % RH Non-Condensing)
Application
Refrigeration, Drying, Metrology, Battery-powered systems, OEM assemblies
Body Style
SIP
Brand/series
HIH-4000
Current, Supply
500 μA @ (Max.)
Function
Humidity
Humidity
0 to 100 % (Operating), 0 to 90 % (Storage)
Output
Voltage
Primary Type
Humidity
Range, Measurement
100% RH
Stability
± 2% RH (Typ.) @ 50% RH
Technology
Capacitive
Temperature, Operating
-40 to +85 °C
Termination
Solder
Voltage, Supply
5.8 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HIH-4000-002
Manufacturer:
HONEYWELL
Quantity:
1 000
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to otherwise
by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for specific
warranty details. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace,
at its option, without charge those items it finds defective. The
foregoing is buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
While we provide application assistance personally, through
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this
printing. However, we assume no responsibility for its use.
Sensing and Control
Honeywell
1985 Douglas Drive North
Minneapolis, MN 55422
www.honeywell.com/sensing
MISUSE OF DOCUMENTATION
Failure to comply with these instructions could result
in death or serious injury.
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
WARNING
009017-4-EN IL50 GLO Printed in USA
May 2008
© 2008 Honeywell International Inc. All rights reserved.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network
of sales offices, representatives and distributors. For
application assistance, current specifications, pricing or name
of the nearest Authorized Distributor, contact your local sales
office or:
E-mail: info.sc@honeywell.com
Internet: www.honeywell.com/sensing
Phone and Fax:
Asia Pacific
Europe
Latin America
USA/Canada
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result
in death or serious injury.
WARNING
+65 6355-2828
+65 6445-3033 Fax
+44 (0) 1698 481676 Fax
+1-305-883-8257 Fax
+1-815-235-6847
+1-815-235-6545 Fax
+44 (0) 1698 481481
+1-305-805-8188
+1-800-537-6945

Related parts for HIH-4000-002