HIH-4000-002 Honeywell, HIH-4000-002 Datasheet

no-image

HIH-4000-002

Manufacturer Part Number
HIH-4000-002
Description
Board Mount Humidity Sensors HUMIDITY RANGE:0-100 lead pitch SIP
Manufacturer
Honeywell
Datasheets

Specifications of HIH-4000-002

Rh Range
0 % to 100 %
Rh Accuracy
3 %
Package / Case
SIP
Output Type
Analog
Supply Voltage (max)
5.8 V
Supply Current
500 uA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
Through Hole
Accuracy
± 3.5% RH (0-100 % RH Non-Condensing)
Application
Refrigeration, Drying, Metrology, Battery-powered systems, OEM assemblies
Body Style
SIP
Brand/series
HIH-4000
Current, Supply
500 μA @ (Max.)
Function
Humidity
Humidity
0 to 100 % (Operating), 0 to 90 % (Storage)
Output
Voltage
Primary Type
Humidity
Range, Measurement
100% RH
Stability
± 2% RH (Typ.) @ 50% RH
Technology
Capacitive
Temperature, Operating
-40 to +85 °C
Termination
Solder
Voltage, Supply
5.8 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HIH-4000-002
Manufacturer:
HONEYWELL
Quantity:
1 000
HIH-4000 Series
Humidity Sensors
DESCRIPTION
The HIH-4000 Series Humidity Sensors are designed
specifically for high volume OEM (Original Equipment
Manufacturer) users.
Direct input to a controller or other device is made possible by
this sensor’s near linear voltage output. With a typical current
draw of only 200 μA, the HIH-4000 Series is often ideally
suited for low drain, battery operated systems.
Tight sensor interchangeability reduces or eliminates OEM
production calibration costs. Individual sensor calibration data
is available.
FEATURES
Molded thermoset plastic housing
Near linear voltage output vs % RH
Laser trimmed interchangeability
Low power design
Enhanced accuracy
Fast response time
Stable, low drift performance
Chemically resistant
The HIH-4000 Series delivers instrumentation-quality RH
(Relative Humidity) sensing performance in a competitively
priced, solderable SIP (Single In-line Package).
Available in two lead spacing configurations, the RH sensor is
a laser trimmed, thermoset polymer capacitive sensing
element with on-chip integrated signal conditioning.
The sensing element's multilayer construction provides
excellent resistance to most application hazards such as
wetting, dust, dirt, oils and common environmental chemicals.
POTENTIAL APPLICATIONS
Refrigeration equipment
HVAC (Heating, Ventilation and Air Conditioning)
equipment
Medical equipment
Drying
Metrology
Battery-powered systems
OEM assemblies

Related parts for HIH-4000-002

HIH-4000-002 Summary of contents

Page 1

... Manufacturer) users. Direct input to a controller or other device is made possible by this sensor’s near linear voltage output. With a typical current draw of only 200 μA, the HIH-4000 Series is often ideally suited for low drain, battery operated systems. Tight sensor interchangeability reduces or eliminates OEM production calibration costs ...

Page 2

... For HIH-4000-003 and HIH-4000-004 catalog listings only. 2. Device is calibrated at 5 Vdc and 25 ºC. 3. Non-condensing environment. FACTORY CALIBRATION DATA HIH-4000 Sensors may be ordered with a calibration and data printout. See Table 2 and the order guide on the back page. TABLE 2. EXAMPLE DATA PRINTOUT Model ...

Page 3

... FIGURE 1. OPERATING ENVIRONMENT (Non-condensing environment.) FIGURE 2. STORAGE ENVIRONMENT (Non-condensing environment.) 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% -40 -20 Recommended storage zone 100 Temperature ºC Humidity Sensors 120 140 Honeywell Sensing and Control 3 ...

Page 4

... HIH-4000 Series FIGURE 3. TYPICAL OUTPUT VOLTAGE VS RELATIVE HUMIDITY (At 25 ºC and 5 V.) 4 3.5 3 2.5 2 1.5 1 0.5 0 FIGURE 4. TYPICAL OUTPUT VOLTAGE (BFSL) VS RELATIVE HUMIDITY (At 0 ºC, 70 ºC and 5 V.) 4.5 4 3.5 3 2.5 2 1 www.honeywell.com/sensing Relative Humidity (%RH Relative Humidity (%) Sensor Response Sensor Response ...

Page 5

... FIGURE 5. HIH-4000 SERIES MOUNTING DIMENSIONS (For reference only. mm/[in]) HIH-4000-002 HIH-4000-004 4,17 [0.164] 8,59 [0.338] 12,70 MIN. [0.50] -ve +ve OUT 3X 0,38 [0.015] 1,27 [0.050] 2,54 [0.100] HIH-4000-001 HIH-4000-003 HIH-4000-005 4,17 [0.164] 1,91 [0.075] +ve -ve OUT 3X 0,38 2,54 ±0,72 2,54 ±0,72 [0.10 ±0.03] [0.10 ± ...

Page 6

... ORDER GUIDE Catalog Listing Description HIH-4000-001 Integrated circuit humidity sensor, 2,54 mm [0.100 in] lead pitch SIP HIH-4000-002 Integrated circuit humidity sensor, 1,27 mm [0.050 in] lead pitch SIP HIH-4000-003 Integrated circuit humidity sensor, 2,54 mm [0.100 in] lead pitch SIP, calibration and data printout HIH-4000-004 Integrated circuit humidity sensor, 1,27 mm [0.050 in] lead pitch SIP, calibration and data printout ...

Page 7

... THIS PAGE INTENTIONALLY LEFT BLANK. Humidity Sensors Honeywell Sensing and Control 7 ...

Page 8

... In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing ...

Related keywords