TSL2561T TAOS, TSL2561T Datasheet - Page 5

Light to Digital Converters Light to Digital with I2C

TSL2561T

Manufacturer Part Number
TSL2561T
Description
Light to Digital Converters Light to Digital with I2C
Manufacturer
TAOS
Datasheets

Specifications of TSL2561T

Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
- 30 C
Mounting Style
SMD/SMT
Package / Case
TMB
Response Time
400ms
Output Current
6mA
Supply Voltage Range Dc
2.7V To 3.6V
Supply Current
0.6mA
Operating Temperature Range
-30°C To +70°C
Operating Temperature Min
-30°C
Rohs Compliant
Yes
Operating Temperature Max
70°C
Sensor Output
I2C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TSL2561T
Manufacturer:
IR
Quantity:
836
Part Number:
TSL2561T
Manufacturer:
AMS
Quantity:
20 000
Part Number:
TSL2561T
0
NOTES: 2. Optical measurements are made using small-angle incident radiation from light-emitting diode optical sources. Visible 640 nm LEDs
The LUMENOLOGY r Company
3. The 640 nm irradiance E
4. The 940 nm irradiance E
5. Integration time T
6. Full scale ADC count value is limited by the fact that there is a maximum of one count per two oscillator frequency periods and also
7. Low gain mode has 16
8. The sensor Lux is calculated using the empirical formula shown on p. 22 of this data sheet based on measured Ch0 and Ch1 ADC
and infrared 940 nm LEDs are used for final product testing for compatibility with high-volume production.
λp = 640 nm and spectral halfwidth Δλ½ = 17 nm.
λp = 940 nm and spectral halfwidth Δλ½ = 40 nm.
described in the Register Set section. For nominal f
Field value 00: T
Field value 01: T
Field value 10: T
Scaling between integration times vary proportionally as follows: 11/322 = 0.034 (field value 00), 81/322 = 0.252 (field value 01),
and 322/322 = 1 (field value 10).
by a 2-count offset.
Full scale ADC count value = ((number of clock cycles)/2 − 2)
Field value 00: Full scale ADC count value = ((11
Field value 01: Full scale ADC count value = ((81
Field value 10: Full scale ADC count value = 65535, which is limited by 16 bit register. This full scale ADC count value is reached
for 131074 clock cycles, which occurs for T
count values for the light source specified. Actual Lux is obtained with a commercial luxmeter. The range of the (sensor Lux) / (actual
Lux) ratio is estimated based on the variation of the 640 nm and 940 nm optical parameters. Devices are not 100% tested with
fluorescent or incandescent light sources.
int
int
int
int
= (11
= (81
= (322
, is dependent on internal oscillator frequency (f
y
×
×
lower gain than high gain mode: (1/16 = 0.0625).
e
e
×
918)/f
918)/f
is supplied by an AlInGaP light-emitting diode with the following characteristics: peak wavelength
is supplied by a GaAs light-emitting diode with the following characteristics: peak wavelength
918)/f
osc
osc
osc
= 13.7 ms
= 101 ms
r
= 402 ms
int
www.taosinc.com
= 178 ms for nominal f
×
×
918)/2 − 2) = 5047
osc
918)/2 − 2) = 37177
= 735 kHz, nominal T
osc
osc
) and on the integration field value in the timing register as
= 735 kHz.
int
LIGHT-TO-DIGITAL CONVERTER
= (number of clock cycles)/f
r
TSL2560, TSL2561
Copyright E 2009, TAOS Inc.
TAOS059N − MARCH 2009
osc
.
5

Related parts for TSL2561T