G3NE-210T-US-DC12 Omron, G3NE-210T-US-DC12 Datasheet - Page 2

Solid State Relays 12VDC/100-240VAC 10A

G3NE-210T-US-DC12

Manufacturer Part Number
G3NE-210T-US-DC12
Description
Solid State Relays 12VDC/100-240VAC 10A
Manufacturer
Omron
Datasheet

Specifications of G3NE-210T-US-DC12

Control Voltage Range
12 VDC
Load Voltage Rating
264 V
Load Current Rating
10 A
Contact Form
1 Form A
Output Device
SSR
Mounting Style
PCB
Relay Type
Low Profile Hockey Puck
Termination Style
Solder Terminal
Control Voltage Type
DC
Input Voltage
9.6VDC To 14.4VDC
Load Current
10A
Load Voltage Range
75VAC To 264VAC
Switching Mode
Zero Cross
Relay Terminals
Quick Connect
Mounting Type
PC Board
Control Voltage Max
14.4V
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G3NE-210T-US-DC12
Manufacturer:
Omron Electronics
Quantity:
135
Specifications
■ Ratings
Input
Note: Each model has 5-VDC, 12-VDC, and 24-VDC input versions.
Output
Note: 1. The load current varies depending on the ambient temperature. Refer to Load Current vs. Ambient Temperature under Engineering Data
■ Characteristics
422
5 VDC
12 VDC
24 VDC
G3NE-205T(L)(-2)-US
G3NE-210T(L)(-2)-US
G3NE-220T(L)(-2)-US
Operate time
Release time
Output ON voltage drop
Leakage current
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Certified standards
Weight
Rated voltage
2. These values apply when using a dedicated heat sink or a radiation plate of specified size.
for details.
Model
Item
Solid State Relays
(at an Ambient Temperature of 25°C)
4 to 6 VDC
9.6 to 14.4 VDC
19.2 to 28.8 VDC
Operating voltage
100 to 240 VAC
Rated load voltage Load voltage range
1/2 of load power source cycle + 1 ms max.
1/2 of load power source cycle + 1 ms max.
1.6 V (RMS) max.
2 mA max. (at 100 VAC)
5 mA max. (at 200 VAC)
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min
Malfunction: 10 to 55, 1.5-mm double amplitude
Malfunction: 1,000 m/s
Operating:–30°C to 80°C (with no icing or condensation)
Storage:–30°C to 100°C (with no icing or condensation)
Operating:45% to 85%
UL File No.E64562/CSA File No. LR35535
TÜV R9051064 (VDE0435) (EN60950)
Approx. 37 g
G3NE
4 VDC max.
9.6 VDC max.
19.2 VDC max.
Must operate
75 to 264 VAC
G3NE-2@@T(-2)-US
2
(approx. 100G)
Voltage level
1 VDC min.
Must release
0.1 to 5 A
0.1 to 10 A
(See note 2)
0.1 to 20 A
(See note 2)
With heat sink
Applicable load
250 Ω±20%
600 Ω±20%
1.6 kΩ±20%
With zero cross function Without zero cross function
Load current
1 ms max.
(See note 1)
0.1 to 5 A
0.1 to 5 A
0.1 to 5 A
Without heat sink
G3NE-2@@TL(-2)-US
Input impedance
300 Ω±20%
800 Ω±20%
60 A (60 Hz, 1 cycle)
150 A (60 Hz, 1 cycle)
220 A (60 Hz, 1 cycle)
Inrush current