CC-24K2N-CS5 Copeland Communications Inc, CC-24K2N-CS5 Datasheet

no-image

CC-24K2N-CS5

Manufacturer Part Number
CC-24K2N-CS5
Description
MODEM WORLD NET 2400BAUD 5V
Manufacturer
Copeland Communications Inc
Datasheet

Specifications of CC-24K2N-CS5

Data Format
V.21, V.22, V.23, Bell 103
Baud Rates
2.4k
Interface
UART
Voltage - Supply
4.2 V ~ 7 V
Mounting Type
Surface Mount
Package / Case
Module
For Use With
539-1002 - KIT EVALUATION WORLD MODEM II
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
Applications
Description
© 2005 Copeland Communications, Inc.
?
?
?
?
?
?
?
?
?
?
?
The World modem™ NET is a compact integrated modem with embedded internet link controller. The
modem features a transformer-less DAA meeting global telephone system requirements, no electro-
mechanical components and flexible DSP data pump. The modem is user-configurable to meet virtually all
global telecom requirements. The modem supports serial host communications via flexible internal UART.
The modem conforms to the industry standard Socket Modem™ mechanical and interface specifications.
Because of its built-in features and flexibility, many applications and OEM products can be created using the
World Modem™ NET. The World Modem™ NET is an ideal modem for world-wide embedded applications
due to its flexibility, global compliance, small size, low power consumption and upgradeability. Copeland
Communications World modems are software and plug compatible and available in 2400, 14.4K, 33K or 56K
baud versions.
In addition, the World Modem™ .NET mediates an internet link via its embedded controller. This provides an
extended AT command set providing a simple, low overhead interface to the internet. The World Modem™
NET also provides interfaces to SPI, I2C and general purpose IO signals. The base version includes support
for IP, TCP, UDP, DNS, HTTP client and PING. SMTP, FTP and other features are available as options.
The embedded controller automatically configures the modem interface and is controlled by an extension to
the AT command set.
Self-contained 300 – 56K baud modem family
V.42, V.42bis V.92, MNP4 Error Correction
Compliant with global regulatory standards
Standard & Extended AT command set
Serial host interface
Supports TCP and UDP ports
Supports standard alarm protocols
Global Embedded applications
Point-of-sale terminals
Mobile terminals
Vending & gaming machines
World Modem™ NET
Data Sheet
Page 1 of 64
?
?
?
?
?
?
?
?
?
?
?
Caller ID, Call Progress & Fast Connect
Phone Line Snoop and Tamper Detection
Compatible with all Copeland Communications
2400, 14.4K, 33K and 56K high speed socket
modems
Socket Modem™ compatible
Low power consumption – 3.3 or 5 V operation
Low Power Standby Mode
Small footprint – 1.045” X 2.54”
Security Systems
Remote monitoring & control
Remote telemetry and SCADA
OEM applications
World Modem NET Datasheet Rev 1.0
World Modem™ NET

Related parts for CC-24K2N-CS5

CC-24K2N-CS5 Summary of contents

Page 1

Features ? Self-contained 300 – 56K baud modem family ? V.42, V.42bis V.92, MNP4 Error Correction ? Compliant with global regulatory standards ? Standard & Extended AT command set ? Serial host interface ? Supports TCP and UDP ports ? ...

Page 2

... Table of Contents Features ........................................................................................................................................ 1 Applications ................................................................................................................................. 1 Description....................................................................................................................... 1 Table of Contents......................................................................................................................... 2 Block Diagram ............................................................................................................................. 3 Host Interface................................................................................................................... 4 Mechanical Outline...................................................................................................................... 5 Detailed Specifications ................................................................................................................ 6 User-Access Registers (U-Registers)......................................................................................... 39 FCC Compliance........................................................................................................................ 60 CE DECLARATION OF CONFORMITY ............................................................................... 62 Revision Information ................................................................................................................. 63 Contact Information ................................................................................................................... 64 Legal .......................................................................................................................................... 64 © 2005 Copeland Communications, Inc. Data Sheet World Modem™ NET Page World Modem NET Datasheet Rev 1.0 ...

Page 3

Block Diagram © 2005 Copeland Communications, Inc. Data Sheet World Modem™ NET Page World Modem NET Datasheet Rev 1.0 ...

Page 4

Host Interface The host interface control and data signals are 3.3volts. The World modem™ NET modems can be directly connected into 3 volt systems. Connect pin 61 to 3.3V power supply or 5V depending on the model. © ...

Page 5

Mechanical Outline Mechanical The modem module 0.062 thick FR-4 PC board. The module has two rows of 2mm pins located 24mm on center. The module is designed to plug into 2 mm sockets with the same 24 ...

Page 6

... Via programmable control registers DTMF & pulse 3.3 V Nominal 3.0V Minimum 3.6V Maximum 65 mA Operating Maximum (preliminary) 230 µA Standby Maximum (preliminary) Industrial -40C - +85C FCC part 15 FCC part 68 EN50082-1 Page World Modem NET Datasheet Rev 1.0 V.90 V.34 V.32bis CTR-21 ...

Page 7

... Notes: 1. Supported on CC-56K2 only 2. Supported on CC-56K2 and CC-33K2 only © 2005 Copeland Communications, Inc. Data Sheet World Modem™ NET ITU-T V.34 or V.32bis ITU-T V.34 or V.32bis ITU-T V.34, V.32bis, or V.29 ITU-T V.34 or V.32bis ITU-T V ...

Page 8

... Originate mode Answer mode Output Level Permissive-Switched network Notes: 1. Supported on CC-56K2 only. 2. Supported on CC-56K2 and CC-33K2 only. © 2005 Copeland Communications, Inc. Data Sheet World Modem™ NET Selectable bits per character ITU-T V.90, V.34, V.32bis, V.32, V.23, V.22bis, V.22, V.21, Bell 212A, and Bell 103 Two-wire full duplex V ...

Page 9

... Connection Options Phone Types Dialing DTMF Output Level Pulse Dial Ratio Ring Cadence Call Progress Monitor Notes: 1. Supported on CC-56K2 only. 2. Supported on CC-56K2 and CC-33K2 only. © 2005 Copeland Communications, Inc. Data Sheet World Modem™ NET As specified by ITU-T As specified by ITU-T ± 1800 ± ...

Page 10

... DSP data pump, modem controller, on-chip RAM and ROM, codec, DAA and analog output. The World Modem™ NET accepts standard modem AT commands and provides connect rates up to 56/33.6/14.4 kbps full-duplex over the Public Switched Telephone Network (PSTN). The World modem™ NET features a complete set of modem protocols including all ITU-T standard formats kbps. The World modem™ ...

Page 11

Serial data Autobaud The modem includes an automatic baud rate detection feature that allows the host to start transmitting data at any standard DTE rate from 300 bps to 230 kbps. This feature is enabled by default. Flow Control The ...

Page 12

... WARNING: ONLY connect one (1) of the power supply pins to either 3. models. Connecting both pins 57 and 61 to different power supplies WILL damage the modem and/or the system it is installed in. See CCI Common Socket Interface Specification for more details. © 2005 Copeland Communications, Inc. Data Sheet World Modem™ NET Page World Modem NET Datasheet Rev 1 ...

Page 13

... REVERSAL" polarity reversal was detected or "NO POLARITY REVERSAL" polarity reversal was not detected. In each case, the result code is followed by "OK". If the S7 timeout occurs before a busy tone is detected, the modem will report "NO CARRIER". Polarity reversal monitoring begins after the last digit is dialed and ends when the busy tone is detected or S7 timeout occurs ...

Page 14

Basic AT Command Set (Command Defaults in Bold) (Continued) Command In Identification and checksum. I0 Display World Modem chipset version H….etc. I1 Display World Modem firmware revision code (numeric). I3 Display line-side revision code. ...

Page 15

... IO Control 0 (U70). The CID, OCD, PPD, and RI bits are also cleared. :M Write to Serial EEPROM. :P Program RAM write. This command is used to upload firmware supplied by CCI to the modem. Contact CCI for more information. :R User-Access Register Read. This command allows the user to read from user-access registers. The format is " ...

Page 16

Basic AT Command Set (Command Defaults in Bold) (Continued) Command +DR=X Data Compression Reporting. X Mode 0 Disabled 1 Enabled If enabled, the intermediate result code is transmitted at the point after error control negotiation. The format of the result ...

Page 17

... Specifies action taken if an underrun condition occurs after a flag during framed sub-mode. +ESA = A,B,C,E 0 Modem transmits 8-bit HDLC flags on idle. C Specifies action taken if an underrun or overrun condition occurs after a non-flag during +ESA = A,B,C,E,F framed sub-mode. +ESA = 0 Modem transmits abort on underrun in middle of frame. ...

Page 18

Basic AT Command Set (Command Defaults in Bold) (Continued) Command +FCLASS = X Class 1 Mode Enable for V.29 fast connect. X Mode 0 Off 1 Enables support for Class 1 mode for use in the V.29 fast connect mode. ...

Page 19

Basic AT Command Set (Command Defaults in Bold) (Continued) Command +GCI = X Country Settings - Automatically configure all registers for a particular country. X Country 0 Japan 9 Australia A Austria F Belgium 16 Brazil 1B Bulgaria 20 Canada ...

Page 20

Basic AT Command Set (Command Defaults in Bold) (Continued) Command +GCI = X (cont) 82 Norway 87 Paraguay 89 Philippines 8A Poland 8B Portugal 9C Singapore 9F South Africa A0 Spain A5 Sweden A6 Switzerland B4 United Kingdom B5 United ...

Page 21

... Copeland Communications, Inc. Data Sheet World Modem™ NET Action ITU-T V.21 ITU-T V.22 ITU-T V.22bis ITU-T V.32 (default for CC-14.4K2) ITU-T V.32bis ITU-T V.34 (default for CC-33K2) ITU-T V.90 (default for CC-56K2) Page World Modem NET Datasheet Rev 1.0 ...

Page 22

Basic AT Command Set (Command Defaults in Bold) (Continued) Command +PCW = X Controls the action to be taken upon detection of call waiting. X Mode 0 Toggle RI# and collect Type II Caller ID if enabled by +VCID. 1 ...

Page 23

... V.34 with automatic fallback (33.6 kbps to 300 bps) ( default for CC-33K2) &H3 V.34 only (33.6 kbps to 2400 bps) &H4 ITU-T V.32bis with automatic fallback (14.4 kbps to 300 bps) (default for CC-14.4K2) &H5 ITU-T V.32bis only (14.4 kbps to 4800 bps) &H6 ITU-T V.22bis only (2400 bps to 1200 bps) © ...

Page 24

... Initiate ITU-T V.54 (ANALOOP) test. Modulation set by &H AT command. Test loop is through the DSP (CC-14.4K2/CC-33K2/CC-56K2 only). The modem echoes data from TX pin back to RX pin. &T3 Initiate ITU-T V.54 (ANALOOP) test. Modulation set by &H AT command. Test loop is through the DSP, DAA interface section, DAA interface and analog hybrid circuit ...

Page 25

Extended AT& Command Set (Command Defaults in Bold) (Continued) Command &X1 Automatic determination of telephone line type. Result code: WXYZn line supports DTMF dialing line is pulse dial only line supports 20 ...

Page 26

Extended AT% Command Set Command %$ Display AT% command settings. %B Report blacklist. See also S42 register. %Cn Data compression %C0 Disable V.42bis and MNP5 data compression %C1 Enable V.42bis in transmit and receive paths. If MNP is selected (\N2), ...

Page 27

... V.42 (LAPM) reliable mode (or drop call) - Same as \N3 except that the modem drops the call instead of connecting in MNP or wire mode. \N5 V.42 and MNP reliable mode - The modem attempts to connect with V.42 successful, MNP is attempted. If MNP is unsuccessful, the call is dropped. \Pn Parity type will be automatically set in autobaud mode. ...

Page 28

Extended AT\ Command Set (Command Defaults in Bold) (Continued) Command \Tn DTE rate - Change DTE rate. When the modem is configured in autobaud mode (default), \T0 through \T15 will lock the new baud rate and disable autobaud. \T0 300 ...

Page 29

AT+I™ Command Set (Command Defaults in Bold) Command \En Echo Mode: 0 – Don’t echo characters. 1 – Echo all host characters. PAR Update Parameter Value – The updated value is stored in volatile memory (RAM). If power is lost, ...

Page 30

... Responds with a handle to the socket. A maximum of two listen sockets are supported. LSST:<hn> Listen Socket Status – Responds with a list of active Socket handles accepted for listen socket identified by handle <hn>. SST:<hn> Single Socket Status – Responds with the status of a single socket identified by handle <hn>. ...

Page 31

... Modem failed to respond 71 – No dial tone response 72 – No carrier modem response 73 – Dial failed 74 – Modem connection with ISP lost 75 – Access denied to ISP server 80 – No suitable message in mailbox 81 – Unable to locate SMTP server 82 – SMTP server timed out 83 – SMTP failed 84-86 – ...

Page 32

... IP registration failed after all methods specified 94 – In “Always Online” mode, connection was lost and reestablished 95 – A watchdog reset event has occurred and restarted the processor 96 – A remote host, that had taken over the processor through the LATI port, has disconnected 97 – ...

Page 33

... Not an FTP session handle 507 – FTP server not found 508 – Timeout when connecting to FTP server 509 – Failed to login to FTP server (bad username, username or account) 510 – FTP command could not be completed 511 – FTP data socket could not be opened 512 – ...

Page 34

... Result Codes Numeric Meaning Command was successful 0 Link established at 300 bps or higher 1 Incoming ring detected 2 Link dropped 3 Command failed 4 Link established at 1200 5 Dial tone not present 6 Line busy 7 Remote not answering 8 Ringback detected 9 Link established at 2400 10 Link established at 4800 11 Link established at 9600 ...

Page 35

... This message only supported on CC-56K2 and CC-33K2 the only verbal response code that does not follow the <CR><LF> Result Code<CRF><LF> standard. There is no leading <CR><LF> 3. This message is only supported on the CC-56K2 © 2005 Copeland Communications, Inc. Data Sheet World Modem™ ...

Page 36

S-Registers The S command allows reading (Sn?) or writing ( the S-registers. The S-registers store values for functions that typically are rarely changed, such as timers or counters, and the ASCII values of control characters such as carriage ...

Page 37

S Register Definition S-Register (Decimal) 0 Automatic answer - Number of rings the modem must detect before answering a call. 0 disables auto answer. 1 Ring counter. 2 ESC code character. 3 Carriage return character. 4 Linefeed character. 5 Backspace ...

Page 38

S-Register Description (Continued) S-Register (Decimal) 42 Blacklisting - The modem will not dial the same number fore than two times in three minutes. An attempt to dial a 3rd time will result in a "BLACKLISTED" result code. If the blacklist ...

Page 39

... User-Access Registers (U-Registers) The :U AT command is used to write these 16-bit U-Registers and the :R command is used to read them. U- registers are identified by a hexadecimal (hex) address. Register Name U00 DT1A0 DT1 registers set the coefficients for stage 1 of the Dial Tone Detect filter. Default is for ...

Page 40

... User-Access Registers (continued) Register Name U17 BT1A0 BT1 registers set the coefficients fo stage 1 of the Busy Tone Detect filter. Default is for U18 BT1B1 FCC countries. U19 BT1B2 U1A BT1A2 U1B BT1A1 U1C BT2A0 Busy tone detect filter stage 2 biquad coefficients. U1D ...

Page 41

... User-Access Registers (continued) Register Name U33 RMOT Ringback cadence minimum on time in seconds multiplied by 7200. U34 DTWD Window to look for dialtone in seconds multiplied by 1000. U35 DMOT Minimum dialtone on time in seconds multiplied by 7200. U37 PD0 Number of pulses to dial 0. U38 PD1 Number of pulses to dial 1. ...

Page 42

... User-Access Registers (continued) Register Name U4F FHT Flash Hook Time. Time corresponding with "!" or "&" dial modifier that the modem goes on-hook during a flash hook (ms units). U50 LCDN Loop current debounce on time (ms units). U51 LCDF Loop current debounce off time (ms units). ...

Page 43

... User-Access Registers (continued) Register Name U87 SAM U9F SASF UA0 SC0 UA1 SC1 UA2 SC2 UA3 SC3 UA4 SC4 UA5 SC5 UA6 SC6 UA7 SC7 UA8 SC8 UA9 SC9 UAA V29MODE © 2005 Copeland Communications, Inc. Data Sheet World Modem™ NET Description This is a bit-mapped register ...

Page 44

Bit Mapped U-Register Summary Reg. Name Bit Bit Bit U4D MOD1 TOCT NHFP U53 MOD2 REV U62 DAAC1 U63 DAAC3 U65 DAAC4 PWMG PDN U66 DAAC5 U67 ITC1 MIN[1:0] U68 ITC2 U6A ITC4 U6C LVS U6E CK1 ...

Page 45

... CTE Calling Tone Enable Disable Enable. 2:0 Reserved Read returns 0. © 2005 Copeland Communications, Inc. Data Sheet World Modem™ NET D11 D10 NHFD CLPD CCAD FTP DSPDM R/W R/W R/W R/W R/W Function Page World Modem NET Datasheet Rev 1 DGT18 ...

Page 46

... Automatic Calibration Time set to 426 ms Automatic Calibration Time set to 106 ms Isolation Digital Loopback (see the AT&T commands Loopback occurs beyond the DAA interface, out to and including the analog hybrid circuit Enables digital loopback mode across isolation barrier only. 0 Reserved Must be set to 0. ...

Page 47

U63 DAAC3 Bit D15 D14 D13 D12 Name LCS[7:0] Type Rest settings = 0x0003 Bit Name Off-Hook Loop Current (1.1 mA/bit). 15:8 lcs[7:0] AC Termination Select. 7:4 ACT[3:0] ACT[3:0] 0000 0011 0100 1111 3:0 Reserved Read returns 0x3. U65 DAAC4 ...

Page 48

U66 DAAC5 Bit D15 D14 D13 D12 Name Type Reset settings = 0x0040 Bit Name 15:7 Reserved Read returns 0. 6 FDT Frame Detect. (Typically used only for board-level debug Indicates the modem has not established frame lock. ...

Page 49

U67 ITC1 Bit D15 D14 D13 D12 Name MINI[1:0] Type R/W Reset settings = 0x0008 Bit Name 15:14 Reserved Read returns 0. 13:12 MINI[1:0] Minimum Operational Loop Current. Adjusts the minimum loop current at which the DAA can operate. Increasing ...

Page 50

... When set, the DAA responds automatically to a collapse of the line-derived power supply during a billing tone event. When off-hook, if BTE = 1 and BTD goes high, the dc termination is released (800? presented to the line). If BTE and RIM (U70, bit 9) are set (U70, bit1) interrupt also occurs when BTD goes high. 1 ROV Receive Overload ...

Page 51

U6A ITC4 Bit D15 D14 D13 D12 Name Type Reset settings = N/A Bit Name 15:3 Reserved Do not modify. 2 OVL Overload Detected. This bit has the same function as ROV, but clears itself after the overload has been ...

Page 52

... Parallel phone detected since last off-hook event. Clears on :I read Ring Indicator. Active high bit when the modem is on-hook, indicates ring event has occurred. Clears on :I read. 0 DCD Data Carrier Detect (status). Active high bit indicates carrier detected (equivalent to inverse of DCD# pin). ...

Page 53

U71 IO1 Bit D15 D14 D13 D12 Name Type Reset settings = 0x0000 Bit Name 15:5 Reserved Read returns zero. 4 COMP 0 = Disables compression (PCM mode Enables linear compression. 3:1 Reserved Read returns zero. 0 PRT ...

Page 54

... Delay between when the modem goes off-hook and the off-hook intrusion algorithm begins. Default HOI Hang-Up On Intrusion Modem will not automatically hang up when and off-hook PPD interrupt occurs Modem automatically hangs PPD interrupt. If %Vn command are set, HOI also causes the "LINE IN USE" result code upon PPD interrupt. 10 Reserved Read returns zero ...

Page 55

U78 GEN3 Bit D15 D14 D13 D12 Name IB[1:0] Type Reset settings = 0x0000 Bit Name 15:14 IB[1:0] Intrusion Blocking. Defines the method used to block the off-hook intrusion algorithm from operation after dialing has begun intrusion ...

Page 56

U79 GEN4 Bit D15 D14 D13 D12 Name Type Reset settings = 0x0000 Bit Name 15:5 Reserved Read returns 0. 4:0 LVCS[4:0] Line Voltage Current Sense. Represents either the line voltage, loop current, or on-hook line monitor. On-Hook Voltage Monitor ...

Page 57

... ADD Adaptive Dialing 0 = Disable Enable. Attempt DTMF dial the fall back to pulse dial if unsuccessful. First digit is dialed as DTMF dialtone is still present after two seconds, the modem will redial as pulse dialtone detected after two seconds, the modem will continue to dial as DTMF. 5:3 Reserved Read returns zero ...

Page 58

U7C GENC Bit D15 D14 D13 D12 Name Type Reset settings = 0x0000 Bit Name 15:5 Reserved Read returns zero. 4 RIGPO RI# RI#, follows this bit when RIGPIOEN = 1b. 3:1 Reserved Read returns zero. 0 RIGPOEN 0 = ...

Page 59

... Generate <EM><0x45> ("E" for error) in response to any unrecognized in-band commands. 8 FSMS Framed Sub-Mode Startup 0 = Upon successful connection, enter Transport Sub-Mode. An <EM><FLAG> is required to enter Framed Sub-Mode Upon successful connection, immediately enter Framed Sub-Mode. The first received <EM><ERR> from a successful hunt is transformed into an <EM><flag>. ...

Page 60

... Ordering Part Number CC-2400K2N-CS CC-14.4K2N-CS CC-33K2N-CS CC-56K2N-CS CC-92K2N-CS CC-2400K2N-CS5 CC-14.4K2N-CS5 CC-56K2N-CS5 CC-56K2N-CS5 CC-92K2N-CS5 C = Commercial temperature I = Industrial temperature (contact factory) Blank = 3.3V power supply power supply Contact factory for special configurations. © 2005 Copeland Communications, Inc. Data Sheet World Modem™ NET Description 2400 baud, 3.3V 70° ...

Page 61

... FCC Compliance Certification Number: US:COPMM00BCC-xxK2 AC-REN: 0.0B DC-REN: NA Connectors: RJ11C Compliance: FCC Part 15 and Part 68 © 2005 Copeland Communications, Inc. Data Sheet World Modem™ NET Page World Modem NET Datasheet Rev 1.0 ...

Page 62

... Manufacturer’s Name: Copeland Communications, Inc. Manufacturer’s Address: 440 Colony Place Gahanna, OH, USA 43230 Type of Equipment: Information Technology Equipment Model No.: CC-xxK2 World Modem II Family Year of Manufacture: 2004 © 2005 Copeland Communications, Inc. Data Sheet World Modem™ NET 89/336/EEC with Amending Directives: ...

Page 63

Revision Information Revision 1.0 Initial release © 2005 Copeland Communications, Inc. Data Sheet World Modem™ NET Page World Modem NET Datasheet Rev 1.0 ...

Page 64

... It is your responsibility to ensure that your application meets with your specifications. No representation or warranty is given and no liability is assumed by Copeland Communications, Incorporated with respect to the accuracy or use of such information, or infringement of patents or other intellectual property rights arising from such use or otherwise. Use of Copeland Communication’ ...

Related keywords