RI-27A Coto Technology, RI-27A Datasheet - Page 2

SWITCH MAGNETIC .5A 20-34AT

RI-27A

Manufacturer Part Number
RI-27A
Description
SWITCH MAGNETIC .5A 20-34AT
Manufacturer
Coto Technology
Series
RI-27r
Type
Glass Bodyr
Datasheet

Specifications of RI-27A

Circuit
SPST-NO
Must Operate
20 ~ 34AT
Must Release
7 ~ 19.5AT
Switching Current (dc) (max)
500mA
Switching Voltage (dc) (max)
200V
Switching Power (max)
10W
Magnet
Not Specified
Mounting Type
Non-Standard (Axial)
Termination Style
Axial (2 Leads)
Switch Type
Dry-Reed
Contact Form
SPST - NO
Contact Rating
500 mAmps
Magnet Type
Electromagnet
Operate Range
20 At to 34 At
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
306-1082
RI27A
End of life criteria:
Switching different loads involves different life expect-
ancy and reliability data. Further information is avail-
able on request.
Mechanical Data
Contact arrangement is normally open; lead finish is
tinned; net mass is approximately 100 mg; and can be
mounted in any position.
Shock
RI-27AA; RI-27A
The switches are tested in accordance with “IEC 68-2-
27”, test Ea (peak acceleration 150 G, half sinewave;
duration 11 ms). Such a shock will not cause an open
switch (no magnetic field present) to close, nor a switch
kept closed by an 80 AT coil to open.
Vibration
The switches are tested in accordance with “IEC 68-2-
6”, test Fc (acceleration 10 G; below cross-over fre-
quency 57 to 62 Hz; amplitude 0.75 mm; frequency
range 10 to 2000 Hz, duration 90 minutes). Such a
vibration will not cause an open switch (no magnetic
field present) to close, nor a switch kept closed by an
80 AT coil to open.
Contact resistance > 2Ω after 4 ms
Release time > 0.7 ms (latching or contact sticking).
RI-27 Series Dry Reed Switch
For Most Recent Data, Consult the Coto Technology Website:
Mechanical Strength
The robustness of the terminations is tested in accor-
dance with “IEC 68-2-21”, test Ua
Operating and Storage Temperature
Operating ambient temperature; min: -55°C; max:
+125°C.
Storage temperature; min: -55°C; max: +125°C.
Note:
permissible. For more information contact your nearest
Coto Technology sales office.
Soldering
The switch can withstand soldering heat in accordance
with “IEC 68-2-20”, test Tb, method 1B: solder bath at
350 ±10° C for 3.5 ±0.5 s. Solderability is tested in
accordance with “IEC 68-2-20” test Ta, method 3:
solder globule temperature 235°C; ageing 1b: 4 hours
steam.
Welding
The leads can be welded
Mounting
The leads should not be bent closer than 1 mm to the
glass-to-metal seals. Stress on the seals should be
avoided. Care must be taken to prevent stray magnetic
fields from influencing the operating and measuring
conditions.
www.cotorelay.com
Temperature excursions up to 150°C may be
6
E-mail: sales@cotorelay.com
1
(load 10 N).
105