BGA/CSP-NK OKI METCAL, BGA/CSP-NK Datasheet - Page 10

no-image

BGA/CSP-NK

Manufacturer Part Number
BGA/CSP-NK
Description
KIT NOZZLE BGA/CSP
Manufacturer
OKI METCAL
Datasheet

Specifications of BGA/CSP-NK

Tip - Type
Rework
Tip - Size
Assorted Sizes
Tip - Shape
Quad
For Use With/related Products
BGA and CSP Rework systems
Other names
BGACSPNK
8
PLACEMENT SIDE - Figure 2
11. Vacuum LED - Illuminates to indicate vacuum is active.
12. Theta Adjustment Knob – Rotates the component to allow rotational alignment.
13. Fine Z-Axis Adjustment Knob –Raises and lowers the position of the component while suspended by
14. Z-Axis Control Knob - Rotating this knob clockwise raises the vacuum head, while rotating counter-
15. Light Adjustment Ring (Iris) –Controls the amount of light entering the camera.
16. Focus Adjustment Ring – Adjusts the focus of the image projected onto the monitor.
17. Zoom Adjustment Ring – Varies the zoom ratio of the lens.
18. Beam Splitter Knob - Splits the observed image so that only the corners of the component and PCB
19. Center Adjustment Control Knobs - These two knobs are used for adjusting the projected image so
10. Tooling Plate Holder/ Component Slide - The adjustable MPVB tooling plate is mounted here. This
11. Vacuum Selector Switch - When this switch is in the “microswitch” position vacuum is controlled
12. Prism Slide Knob - Pulling this knob towards you accesses the prism to view the component and
13. Z-Axis Stop - The position of this screw
14. Foot Switch Receptacle - The FS-24
Control Unit
BGA/CSP-3500 Control Unit Front Panel - Figure 3
(page 9)
11. Airflow Gauge: Measures the airflow out
12. Main Power Switch
13. Air Flow Control Knob: Adjusts airflow to
by the microswitch located in the vacuum head. When in the “footswitch” position, vacuum is
controlled by the FS-24 Footswitch.
board simultaneously. Pushing this knob
component to be placed.
Note: An image cannot be viewed on the
monitor when the prism is retracted.
determines how far the vacuum head will
travel upward or downward in the Z-Axis.
Footswitch connects to this receptacle.
the vacuum cup. The importance of height adjustment, in reference to focus, will be discussed later
in this manual. Note: Component will be placed incorrectly if height is wrong.
clockwise lowers the vacuum head.
can be viewed and magnified in order to make fine adjustments and perform accurate placement
inspection. This function is not present on CSP-3500 Series Systems.
that it is centered in reference to the monitor.
is used to introduce the component into the optical path of the prism and ensure that component
pick-up is centralized in reference to the vacuum pipette.
put to the Reflow Head (liters/minute).
the reflow head.
Figure 2
6
9
8
forward retracts the prism to allow the
1
7
5
On Back
14
BGA-3500 Series Manual 5/01
On Back
11
2
3
10
12
4
13