MPXV4006GP Freescale Semiconductor, MPXV4006GP Datasheet - Page 3

SENSOR GAUGE PRESS .87PSI MAX

MPXV4006GP

Manufacturer Part Number
MPXV4006GP
Description
SENSOR GAUGE PRESS .87PSI MAX
Manufacturer
Freescale Semiconductor
Series
MPXV4006r
Datasheets

Specifications of MPXV4006GP

Pressure Type
Gauge
Operating Pressure
0.87 PSI
Output
0 ~ 4.7V
Voltage - Supply
4.75 V ~ 5.25 V
Termination Style
PCB
Operating Temperature
-10°C ~ 60°C
Package / Case
8-SOP Side Port
Mounting Style
SMD/SMT
Maximum Operating Temperature
+ 60 C
Minimum Operating Temperature
- 10 C
Operating Supply Voltage
5 V
Supply Current
10 mA
Output Voltage
0.2 V to 4.8 V
Operating Pressure Range
0 To 6kPa
Connection Size
3.175mm
Sensitivity, V/p
766mV/kPa
Sensor Case Style
SOP
No. Of Pins
8
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Sensors
Freescale Semiconductor
integrating the shear-stress strain gauge, temperature
compensation, calibration and signal conditioning circuitry
onto a single monolithic chip.
chip carrier (Case 482). A fluorosilicone gel isolates the die
surface and wire bonds from the environment, while allowing
the pressure signal to be transmitted to the silicon diaphragm.
are based on use of dry air as pressure media. Media, other
than dry air, may have adverse effects on sensor
performance and long-term reliability. Internal reliability and
qualification test for dry air, and other media, are available
Lead
Frame
Wire
Bond
The performance over temperature is achieved by
Figure 2
The MPXV4006G series sensor operating characteristics
Differential Sensing
Figure 2. Cross Sectional Diagram SOP
Element
ON-CHIP TEMPERATURE COMPENSATION, CALIBRATION, AND SIGNAL CONDITIONING
Fluorosilicone
illustrates the gauge configuration in the basic
Gel Die Coat
(Not to Scale)
P2
P1
4.5
3.5
2.5
1.5
0.5
5
4
3
2
1
0
0
Transfer Function:
V
V
TEMP = 10 to 60° C
Die
out
S
= 5.0 V ± 0.25 Vdc
= V
Max
Figure 4. Output versus Pressure Differential
S
*[(0.1533*P) + 0.045] ± 5% V
Die Bond
See Note 5 in Operating Characteristics
Thermoplastic
Case
Steel Cap
Stainless
Differential Pressure (kPa)
3
FSS
Min
from the factory. Contact the factory for information regarding
media tolerance in your application.
interfacing the output of the integrated sensor to the A/D input
of a microprocessor or microcontroller. Proper decoupling of
the power supply is recommended.
pressure input. Typical, minimum and maximum output
curves are shown for operation over a temperature range of
10°C to 60°C using the decoupling circuit shown in
The output will saturate outside of the specified pressure
range.
1.0 µF
Figure 3
Figure 4
Figure 3. Recommended Power Supply Decoupling
(For additional output filtering, please refer to
and Output Filtering Recommendations
Typical
0.01 µF
shows the recommended decoupling circuit for
shows the sensor output signal relative to
Application Note AN1646.)
6
Vs
+5 V
GND
IPS
Vout
MPXV4006G
470 pF
Figure
OUTPUT
3.
3

Related parts for MPXV4006GP