MPXV4006GP Freescale Semiconductor, MPXV4006GP Datasheet - Page 2

SENSOR GAUGE PRESS .87PSI MAX

MPXV4006GP

Manufacturer Part Number
MPXV4006GP
Description
SENSOR GAUGE PRESS .87PSI MAX
Manufacturer
Freescale Semiconductor
Series
MPXV4006r
Datasheets

Specifications of MPXV4006GP

Pressure Type
Gauge
Operating Pressure
0.87 PSI
Output
0 ~ 4.7V
Voltage - Supply
4.75 V ~ 5.25 V
Termination Style
PCB
Operating Temperature
-10°C ~ 60°C
Package / Case
8-SOP Side Port
Mounting Style
SMD/SMT
Maximum Operating Temperature
+ 60 C
Minimum Operating Temperature
- 10 C
Operating Supply Voltage
5 V
Supply Current
10 mA
Output Voltage
0.2 V to 4.8 V
Operating Pressure Range
0 To 6kPa
Connection Size
3.175mm
Sensitivity, V/p
766mV/kPa
Sensor Case Style
SOP
No. Of Pins
8
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
MPXV4006G
2
Table 2. Operating Characteristics
Table 1. Maximum Ratings
Pressure Range
Supply Voltage
Supply Current
Full Scale Output
Offset
Sensitivity
Accuracy
Maximum Pressure (P1 >P2)
Storage Temperature
Operating Temperature
1. Device is ratiometric within this specified excitation range.
2. Full Scale Span (V
3. Offset (V
4. Accuracy (error budget) consists of the following:
5. Auto Zero at Factory Installation: Due to the sensitivity of the MPXV4006G, external mechanical stresses and mounting position can affect
1. Exposure beyond the specified limits may cause permanent damage or degradation to the device.
minimum rated pressure.
• Linearity:
• Temperature Hysteresis: Output deviation at any temperature within the operating temperature range, after the temperature is cycled to
• Pressure Hysteresis:
• Offset Stability:
• TcSpan:
• TcOffset:
the zero pressure output reading. To obtain the 5% FSS accuracy, the device output must be “autozeroed'' after installation. Autozeroing is
defined as storing the zero pressure output reading and subtracting this from the device's output during normal operations.
(3)(5)
(4)(5)
off
) is defined as the output voltage at the minimum rated pressure.
(1)
(2)
FSS
) is defined as the algebraic difference between the output voltage at full rated pressure and the output voltage at the
Parametrics
Characteristic
Output deviation from a straight line relationship with pressure over the specified pressure range.
and from the minimum or maximum operating temperature points, with zero differential pressure applied.
Output deviation at any pressure within the specified range, when this pressure is cycled to and from minimum
or maximum rated pressure, at 25°C.
Output deviation, after 1000 temperature cycles, -30 to 100°C, and 1.5 million pressure cycles, with
minimum rated pressure applied.
Output deviation over the temperature range of 10° to 60°C, relative to 25°C.
Output deviation with minimum pressure applied, over the temperature range of 10° to 60°C, relative to 25°C.
(1)
Element
Sensing
Figure 1. Fully Integrated Pressure Sensor Schematic
(RF = 51kΩ)
(RF = 51kΩ)
(10 to 60°C)
GND
Compensation
Temperature
Gain Stage #1
Thin Film
and
V
S
Pins 1, 5, 6, 7, and 8 are NO CONNECTS
for small outline package device
Symbol
V
P
V/P
Symbol
V
V
FSS
I
OP
S
off
P
S
T
T
max
stg
A
Gain Stage #2
Shift Circuitry
Reference
Ground
and
0.100
4.75
Min
0
-30° to +100°
-10° to +60°
Value
V
out
0.225
24
Typ
766
5.0
4.6
Freescale Semiconductor
0.430
Max
5.25
±5.0
6.0
10
Units
kPa
°C
°C
mV/kPa
%V
Sensors
mAdc
Unit
kPa
Vdc
V
V
FSS