A24-HABUF-P5I Digi International/Maxstream, A24-HABUF-P5I Datasheet - Page 56

no-image

A24-HABUF-P5I

Manufacturer Part Number
A24-HABUF-P5I
Description
2.4GHZ ANTENNA U.FL
Manufacturer
Digi International/Maxstream
Datasheet

Specifications of A24-HABUF-P5I

Antenna Type
Whip
Number Of Bands
1
Frequency
2.4GHz
Gain
2.1dBi
Termination
U.FL
Mounting Type
Bulkhead
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Vswr
-
Height (max)
-
Other names
A24-HABUF-P51
A24-HABUF-P51
Q3655966F

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
A24-HABUF-P5I
Manufacturer:
MXS
Quantity:
36
XBee®/XBee‐PRO®  RF Modules ‐ 802.15.4 ‐ v1.xEx [2009.09.23]
T0 - T7 ((D0-D7) Output Timeout) Command
VL (Firmware Version - Verbose)
VR (Firmware Version) Command
WR (Write) Command
<I/O Settings {I/O Line Passing}> The T0, T1,
T2, T3, T4, T5, T6 and T7 commands are used to
set/read output timeout values for the lines that
correspond with the D0 - D7 parameters. When
output is set (due to I/O line passing) to a non-
default level, a timer is started which when
expired, will set the output to its default level. The timer is reset when a valid I/O packet is
received. The Tn parameter defines the permissible amount of time to stay in a non-default
(active) state. If Tn = 0, Output Timeout is disabled (output levels are held indefinitely).
<Diagnostics> The VL command is used to read
detailed version information about the RF module.
The information includes:
application build date; MAC, PHY and bootloader
versions; and build dates. This command was
removed from firmware 1xC9 and later versions.
<Diagnostics> The VR command is used to read
which firmware version is stored in the module.
XBee version numbers will have four significant
digits. The reported number will show three or four numbers and is stated in hexadecimal nota-
tion. A version can be reported as "ABC" or "ABCD". Digits ABC are the main release number and
D is the revision number from the main release. "D" is not required and if it is not present, a zero
is assumed for D. "B" is a variant designator. The following variants exist:
<(Special)> The WR command is used to write
configurable parameters to the RF module's non-
volatile memory. Parameter values remain in the
module's memory until overwritten by subsequent use of the WR Command.
If changes are made without writing them to non-volatile memory, the module reverts back to pre-
viously saved parameters the next time the module is powered-on.
NOTE: Once the WR command is sent to the module, no additional characters should be sent until
after the “OK/r” response is received.
© 2009 Digi Internatonal, Inc.
• "0" = Non-Beacon Enabled 802.15.4 Code
• "1" = Beacon Enabled 802.15.4 Code
AT Command: ATWR
AT Command: ATVR
Parameter Range: 0 - 0xFFFF [read only]
AT Command: ATVL
Parameter Range:0 - 0xFF
Default Parameter Value: 0x28 (40 decimal)
Minimum Firmware Version Required: v1.x80
- v1.xC8
AT Commands: ATT0 - ATT7
Parameter Range:0 - 0xFF [x 100 msec]
Default Parameter Value:0xFF
Minimum Firmware Version Required: v1.xA0
[x 100 milliseconds]