E2C-GF4B Omron, E2C-GF4B Datasheet - Page 17

no-image

E2C-GF4B

Manufacturer Part Number
E2C-GF4B
Description
AMP PNP 10-30VDC FOR E2C-CR5B
Manufacturer
Omron
Series
E2Cr
Datasheets

Specifications of E2C-GF4B

Amplifier Type
Standard
Voltage - Supply
10 V ~ 30 V
Output Type
PNP
Current - Supply
25mA
Mounting Type
Socket
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E2CGF4B
E2C-A@4A
Using P2CF-11, P2CF-08
When aligning the Amplifier Unit vertically with the Socket, consider
the space required for the hooks and allow a leeway of about 20 mm
above and below the Amplifier Unit.
Mounting Embedded in a Panel
(1)When using the Y92F-30 Embedded Mounting Adapter, insert the
(2)When using the Y92F-70 or Y92F-71 Embedded Mounting
Amplifier Unit into a square hold in the panel, attach the Adapter
from the back and press in to reduce the gap with the panel. Then
secure the Adapter with the screws.
Adapter, just press the Amplifier into a square hole in the panel. If
the panel coating is too thick and the hooks do not lock in place,
spread the hooks from the back by pushing in the directions of the
arrows.
Panel
Insert the Amplifier Unit and
then spread the hooks.
Panel
Insert the Sensor and then
spread the hooks.
P2CF-11
P2CF-08
Hook
20
Hook
Y92F-30
Duct or
other object
Panel
Removing the Amplifier Unit
● Wiring
Self-diagnostic Output
When not using the self-diagnostic output, connect the orange wire to
0 V or cut it and wrap it with insulation tape so that it does not come
into contact with other terminals.
● Miscellaneous
The sensor does not have a water-resistant structure. Do not use it
where it would be subjected to water or water vapor.
• When the Amplifier Unit is mounted using the Y92F-30, loosen the
• Using Y92F-70, Y92F-71
screws on the adapter, spread the hooks at the top and bottom, and
remove the Adapter.
Press in on the hooks with your thumb and forefinger and press
forward on the Amplifier Unit.
E2C/E2C-H
17