JAW050A Lineage Power, JAW050A Datasheet
JAW050A
Specifications of JAW050A
Available stocks
Related parts for JAW050A
JAW050A Summary of contents
Page 1
... Description The JAW050A and JAW075A Power Modules are dc-dc converters that operate over an input voltage range of 36 Vdc to 75 Vdc and provide a regulated dc output. The outputs are fully isolated from the inputs, allowing versatile polarity configurations and grounding connections. The modules have maximum power ratings from typical full-load efficiency of 84% ...
Page 2
... JAW050A and JAW075A Power Modules; dc-dc Converters: 36 Vdc to 75 Vdc Input, 5 Vdc Output Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso- lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet ...
Page 3
... Consult your sales representative or the factory. † These are manufacturing test limits. In some situations, results may differ. Table 3. Isolation Specifications Parameter Isolation Capacitance Isolation Resistance Lineage Power JAW050A and JAW075A Power Modules; dc-dc Converters: 36 Vdc to 75 Vdc Input, 5 Vdc Output (continued) Device Symbol All All ...
Page 4
... JAW050A and JAW075A Power Modules; dc-dc Converters: 36 Vdc to 75 Vdc Input, 5 Vdc Output General Specifications Parameter Calculated MTBF ( max Weight Feature Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See the Feature Descriptions section for additional information. ...
Page 5
... INPUT VOLTAGE, V Figure 2. Typical JAW075A Input Characteristics at Room Temperature Lineage Power JAW050A and JAW075A Power Modules; dc-dc Converters: 36 Vdc to 75 Vdc Input, 5 Vdc Output 0 (V) I 8-3327(F) Figure 3. Typical JAW050A Efficiency vs. Output 7 1 (V) I 8-3328(F) Figure 4. Typical JAW075A Efficiency vs. Output ...
Page 6
... Full Load at Room Temperature and 48 Vdc Input (Waveform Averaged to Eliminate Ripple Component.) 2.5 A 1-0097 Note: Tested without any load capacitance. Figure 8. Typical JAW050A Transient Response to Step Decrease in Load from 50% to 25% of Full Load at Room Temperature and 48 Vdc Input (Waveform Averaged to Eliminate Ripple Component.) Data Sheet April 2008 TIME, t (200 μ ...
Page 7
... Note: Tested without any load capacitance. Figure 10. JAW075A1 Typical Start-Up from Remote On/Off Lineage Power JAW050A and JAW075A Power Modules; dc-dc Converters: 36 Vdc to 75 Vdc Input, 5 Vdc Output Test Configurations BATTERY Note: Measure input reflected-ripple current with a simulated source inductance (L tery impedance. Measure current as shown above. ...
Page 8
... JAW050A and JAW075A Power Modules; dc-dc Converters: 36 Vdc to 75 Vdc Input, 5 Vdc Output Design Considerations Input Source Impedance The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power mod- ule. For the test configuration in Figure 11 µF electrolytic capacitor (ESR < ...
Page 9
... Care should be taken to ensure that the maximum output power of the module remains at or below the maximum rated power. Lineage Power JAW050A and JAW075A Power Modules; dc-dc Converters: 36 Vdc to 75 Vdc Input, 5 Vdc Output SUPPLY CONTACT RESISTANCE ...
Page 10
... JAW050A and JAW075A Power Modules; dc-dc Converters: 36 Vdc to 75 Vdc Input, 5 Vdc Output Feature Descriptions (continued) Output Voltage Set-Point Adjustment (Trim) (continued) Although the output voltage can be increased by both the remote sense and by the trim, the maximum increase for the output voltage is not the sum of both. ...
Page 11
... Solution Given °C A Determine P (Use Figure 20.): Determine airflow (v) (Use Figure 22.): v = 2.3 m/s (460 ft./min.) Lineage Power JAW050A and JAW075A Power Modules; dc-dc Converters: 36 Vdc to 75 Vdc Input, 5 Vdc Output (continued Figure 19. JAW050A Power Dissipation vs. ) for natural convec ...
Page 12
... JAW050A and JAW075A Power Modules; dc-dc Converters: 36 Vdc to 75 Vdc Input, 5 Vdc Output Thermal Considerations Heat Transfer Without Heat Sinks 0.1 m/s (20 ft./min.) 8 1.0 m/s 6 (200 ft./min.) 4 2.0 m/s (400 ft./min LOCAL AMBIENT TEMPERATURE, T Figure 21. Forced Convection Power Derating with No Heat Sink ...
Page 13
... Use Figure 23 to determine air velocity for the 1/4 inch heat sink. The minimum airflow necessary for this module is 1.1 m/s (220 ft./min.). Lineage Power JAW050A and JAW075A Power Modules; dc-dc Converters: 36 Vdc to 75 Vdc Input, 5 Vdc Output Custom Heat Sinks (continued) A more detailed model can be used to determine the ...
Page 14
... JAW050A and JAW075A Power Modules; dc-dc Converters: 36 Vdc to 75 Vdc Input, 5 Vdc Output Outline Diagram Dimensions are in millimeters and (inches). Tolerances: x.x mm ± 0.5 mm (x.xx in. ± 0.02 in.) x.xx mm ± 0.25 mm (x.xxx in. ± 0.010 in.) Top View Side View 0.51 (0.020) 12.7 (0.50) 4.1 (0.16) † ...
Page 15
... Table 5. Device Options Option Short pins: 2.79 mm ± 0.25 mm (0.110 in. +0.020 in./–0.010 in.) Short pins: 3.68 mm ± 0.25 mm (0.145 in. ± 0.010 in.) Lineage Power JAW050A and JAW075A Power Modules; dc-dc Converters: 36 Vdc to 75 Vdc Input, 5 Vdc Output 57.9 (2.28) 4.8 48.3 (1.90) (0.19) 48.26 (1.900) ...
Page 16
... JAW050A and JAW075A Power Modules; dc-dc Converters: 36 Vdc to 75 Vdc Input, 5 Vdc Output Ordering Information (continued) Table 6. Device Accessories Accessory 1/4 in. transverse kit (heat sink, thermal pad, and screws) 1/4 in. longitudinal kit (heat sink, thermal pad, and screws) 1/2 in. transverse kit (heat sink, thermal pad, and screws) 1/2 in ...