LMK107B7224KA-T Taiyo Yuden, LMK107B7224KA-T Datasheet - Page 25

CAP CERM .22UF 10V X7R 0603

LMK107B7224KA-T

Manufacturer Part Number
LMK107B7224KA-T
Description
CAP CERM .22UF 10V X7R 0603
Manufacturer
Taiyo Yuden
Series
LMKr
Datasheet

Specifications of LMK107B7224KA-T

Package / Case
0603 (1608 Metric)
Mounting Type
Surface Mount, MLCC
Operating Temperature
-55°C ~ 125°C
Temperature Coefficient
X7R
Size / Dimension
0.063" L x 0.032" W (1.60mm x 0.80mm)
Applications
General Purpose
Tolerance
±10%
Capacitance
0.22µF
Thickness
0.80mm
Dielectric Characteristic
X7R
Capacitance Tolerance
± 10%
Voltage Rating
10VDC
Capacitor Case Style
0603
No. Of Pins
2
Capacitor Mounting
SMD
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Ratings
-
Lead Spacing
-
Other names
CE LMK107 B7224KA-T::LMK107BJ224KA-T::LMK107BJ224KA-T

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LMK107B7224KA-T
Manufacturer:
TAYO YUDEN
Quantity:
360 000
【Test Methods and Remarks】
【Test Methods and Remarks】
【Test Methods and Remarks】
【Test Methods and Remarks】
* This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
mlcc05_reli_e-01
12. Temperature Cycle ( Thermal Shock)
Specified Value
13. Humidity (Steady state)
Specified Value
14. Humidity Loading
Specified Value
15. High Temperature Loading
Specified Value
Note1
Conditions for 1 cycle/ Step 1: Minimum operating temperature
Number of cycles: 5 times
Measurement shall be conducted : 24±2hrs under the standard condition
Temperature:40±2℃
Humidity:90 to 95% RH
Duration:500
Measurement shall be conducted : 24 ±2hrs under the standard condition
According to JIS C 5102 clause 9.9.
Temperature:40±2℃ Humidity:90 to 95% RH
Duration:500
Applied voltage: Rated voltage
Charge/discharge current:50mA max
Measurement shall be conducted : 24 ±2hrs under the standard condition
According to JIS C 5102 clause 9.10.
Temperature:125±3℃
Duration:1000
Applied voltage: Rated voltage x 2
Charge/discharge current:50mA max
Measurement shall be conducted : 24 ±2hrs under the standard condition
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.
RELIABILITY DATA
Standard condition: Temperature: 5 to 35℃, Relative humidity: 45 to 85 % RH, Air pressure: 86 to 106kPa
+24
-0
+24
-0
+48
-0
hrs
hrs
hrs
Step 2: Normal temperature
Step 3: Maximum operating temperature
Step 4: Normal temperature
When there are questions concerning measurement results, in order to provide correlation data, the test shall be conducted under the following condition.
Temperature: 20±2℃,
Unless otherwise specified, all the tests are conducted under the "standard condition".
Relative humidity: 60 to 70 % RH, Air pressure: 86 to 106kPa
Appearance: No abnormality
Capacitance change: ±2.5% max
Dissipation factor : Initial value
Insulation resistance: Initial value
Withstanding voltage (between terminals) : No abnormality
Appearance: No abnormality
Capacitance change: ±5% max
Dissipation factor : 0.5% max
Insulation resistance 50MΩ μF or 1000MΩ, whichever is smaller
Appearance: No abnormality
Capacitance change: ±7.5% max
Dissipation factor : 0.5% max
Insulation resistance: 25MΩ μF or 500MΩ, whichever is smaller
Appearance: No abnormality
Capacitance change: ±3% max
Dissipation factor : 0.35% max
Insulation resistance: 50MΩ μF or 1000MΩ, whichever is smaller
+0
-3
+0
-3
℃ 30±3 min.
℃ 30±3 min.
2 to 3 min.
2 to 3 min.
Note1
Note1
Note1
Note1
1 1
mlcc05_reli-R2

Related parts for LMK107B7224KA-T