UMK107SD332JA-T Taiyo Yuden, UMK107SD332JA-T Datasheet - Page 10

CAP CER 3300PF 50V 0603 LOW DIST

UMK107SD332JA-T

Manufacturer Part Number
UMK107SD332JA-T
Description
CAP CER 3300PF 50V 0603 LOW DIST
Manufacturer
Taiyo Yuden
Series
CFCAP™r
Datasheet

Specifications of UMK107SD332JA-T

Capacitance
3300pF
Voltage - Rated
50V
Tolerance
±5%
Mounting Type
Surface Mount, MLCC
Operating Temperature
-55°C ~ 125°C
Features
Low Distortion
Applications
RF, Microwave, High Frequency
Package / Case
0603 (1608 Metric)
Size / Dimension
0.063" L x 0.031" W (1.60mm x 0.80mm)
Thickness
0.80mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Ratings
-
Temperature Coefficient
-
Lead Spacing
-
Other names
587-1081-2
CF UMK107 SD332JA-T
Note on standard condition: "standared condition" referred to herein is defined as follows.
When there are questions concerning measurement results: In order to provide correlation data, the test shall be conducted under condition.
Super Low Distortion Multilayer Ceramic Capacitors (CFCAP)
15.Loading under Damp Heat
16.Loading at High Tempera-
RELIABILITY DATA
当社カタログをご使用の際には 「当社製品に関するお断り」 を必ずお読みください。
ture
Temperature: 5 to 35℃, Relative humidity: 45 to 85 %,
Temperature: 20±2℃,
Unless otherwise specified,all the tests are conducted under the "standard condition."
Item
Relative humidity: 60 to 70 %,
Appearance: No abnormality
Capacitance change: ±7.5% max
tanδ:0.5% max
Insulation resistance: 25MΩμF or 500MΩ whichever is smaller
Appearance: No abnormality
Capacitance change: ±3% max
tanδ:0.35% max
Insulation resistance: 50MΩμF or 1000MΩ whichever is smaller
Air pressure: 86 to 106kpa
Air pressure: 86 to 106kpa,
Specified Value
9
Please read the "Notice for TAIYO YUDEN products" before using this catalog.
According to JIS C 5102 clause 9.9.
Temperature:40±2℃
Humidity:90 to 95% RH
Duration:500
Applied voltage: Rated voltage
Charge/discharge current:50mA max
Recovery: Recovery for the following period under the stan-
dard condition after the removal from test chamber: 24±2hrs
According to JIS C 5102 clause 9.9.
Temperature:125±3℃
Duration:1000
Applied voltage: Rated voltage x 2
Recovery: Recovery for the following period under the stan-
dard condition after the removal from test chamber: 24±2hrs
+24
Test Methods and Remarks
0
+48
0
hrs
hrs
2/2
75
4

Related parts for UMK107SD332JA-T