B41605A8158M2S1 EPCOS Inc, B41605A8158M2S1 Datasheet - Page 12

no-image

B41605A8158M2S1

Manufacturer Part Number
B41605A8158M2S1
Description
CAP 1500UF 63V ALUM ELECT SNAP
Manufacturer
EPCOS Inc
Series
B41605r
Datasheet

Specifications of B41605A8158M2S1

Capacitance
1500µF
Voltage Rating
63V
Tolerance
±20%
Lifetime @ Temp.
5000 Hrs @ 125°C
Operating Temperature
-55°C ~ 125°C
Features
Automotive
Ripple Current
9.6A
Esr (equivalent Series Resistance)
28.0 mOhm
Impedance
22 mOhm
Mounting Type
Through Hole
Package / Case
Radial, Can - Snap-In
Size / Dimension
0.866" Dia (22.00mm)
Height
1.575" (40.00mm)
Lead Spacing
0.331" (8.40mm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Surface Mount Land Size
-
Other names
495-3706
B41605A8158M2
Cautions and warnings
Personal safety
The electrolytes used by EPCOS have not only been optimized with a view to the intended
application, but also with regard to health and environmental compatibility. They do not contain
any solvents that are detrimental to health, e.g. dimethyl formamide (DMF) or dimethyl acetamide
(DMAC).
Furthermore, part of the high-voltage electrolytes used by EPCOS are self-extinguishing. They
contain flame-retarding substances which will quickly extinguish any flame that may have been
ignited.
As far as possible, EPCOS does not use any dangerous chemicals or compounds to produce
operating electrolytes. However, in exceptional cases, such materials must be used in order to
achieve specific physical and electrical properties because no safe substitute materials are
currently known. However, the amount of dangerous materials used in our products has been
limited to an absolute minimum. Nevertheless, the following rules should be observed when
handling Al electrolytic capacitors:
Please read Cautions and warnings and
Important notes at the end of this document.
Any escaping electrolyte should not come into contact with eyes or skin.
If electrolyte does come into contact with the skin, wash the affected parts immediately with
running water. If the eyes are affected, rinse them for 10 minutes with plenty of water. If
symptoms persist, seek medical treatment.
Avoid breathing in electrolyte vapor or mists. Workplaces and other affected areas should be
well ventilated. Clothing that has been contaminated by electrolyte must be changed and
rinsed in water.
B41605
Automotive
compact
Page 12 of 17