ZX-XF12 Omron, ZX-XF12 Datasheet - Page 20

no-image

ZX-XF12

Manufacturer Part Number
ZX-XF12
Description
ATTACHMNT SIDEVIEW ZX-LT1001/005
Manufacturer
Omron
Datasheets

Specifications of ZX-XF12

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
ZXXF12
Specifications
*1. Resolution: The resolution is the deviation ( 3 s) in the linear output when connected to the ZX-EDA Amplifier Unit. The above values indicate
*2. Linearity: The linearity is given as the error in an ideal straight line displacement output when measuring the standard reference object. The
*3. Temperature characteristic: The temperature characteristic is measured with OMRON's standard reference object at 1/2 of the measurement
*4. The ambient temperature given is only for the sensor head. It is 10 to 60 C for the preamp.
*5. The value given is for an ambient temperature of 25 C.
*6. Do not use in moist environments because the case is not waterproof.
Measurement range
Sensing object
Standard reference object
Resolution *1
Linearity *2
Linear output range
Temperature characteristic *3
(including Amplifier Unit)
Ambient temper-
ature
Ambient humidity
Insulation resistance
Dielectric strength
Vibration resistance (destruction)
Shock resistance (destruction)
Degree of protection (Sensor Head)
Connection method
Weight (packed state)
Materials
Accessories
the deviations observed 30 minutes after the power is turned ON.
(The resolution is measured with OMRON's standard reference object at 1/2 of the measurement range with the ZX-EDA set for the maximum
average count of 4096.)
The resolution is given at the repeat accuracy for a stationary workpiece, and is not an indication of the distance accuracy. The resolution may
be adversely affected under strong electromagnetic fields.
linearity and measurement values vary with the object being measured.
range.
Sensor Heads
Operating
Storage
Sensor
Head
Preamplifier
*4
Case
Sensing
surface
*4
Model
ZX Series (ZX-E)
0 to 0.5 mm
Magnetic metals (Measurement ranges and linearities are different for non-magnetic metals.)
18
Material: ferrous (S50C)
1 m
Same as measurement range.
0.15% F.S./ C
0 to 50 C (with no
icing or conden-
sation)
Operating and storage: 35% to 85% (with no condensation)
50 M
1,000 VAC, 50/60 Hz for 1 min between charged parts and case
10 to 55 Hz with 1.5-mm double amplitude for 2 h each in X, Y, and Z directions
500 m/s
IEC60529, IP65
Connector relay (standard cable length: 2 m)
Approx. 120 g
Brass
Heat-resistant ABS
PES
Amplifier Mounting Brackets (ZX-XBE1), Instruction Manual
0.5% F.S.
ZX-EDR5T
18
min. (at 500 DC)
2
, 3 times each in X, Y, and Z directions
3 mm
0 to 1 mm
0.07% F.S./ C
IEC60529, IP67
Approx. 140 g
Stainless steel Brass
10 to 60 C (with no icing or condensation)
20 to 70 C (with no icing or condensation)
ZX-ED01T
Smart Sensors (Inductive Displacement Type)
0 to 2 mm
30
ZX-ED02T/
EM02T
30
3 mm 60
0 to 7 mm
Approx. 160 g
ZX-EM07MT
60
3 mm
0 to 4 mm
Approx. 130 g
Zinc (nickel-
plated)
ZX-EV04T
0 to 2 mm
45
0.1% F.S./ C
IEC60529,
IP60 *6
Approx. 160 g
Brass
PEEK
1.0% F.S. *5
10 to 200 C
20 to 200 C
ZX-EM02HT
45
3 mm
21

Related parts for ZX-XF12