VPS24-1000 Triad Magnetics, VPS24-1000 Datasheet

XFRMR PWR 24.0VCT 1.0A QC .187

VPS24-1000

Manufacturer Part Number
VPS24-1000
Description
XFRMR PWR 24.0VCT 1.0A QC .187
Manufacturer
Triad Magnetics
Series
Chassis Mount: World Series™r
Type
Standardr
Datasheets

Specifications of VPS24-1000

Maximum Power
25 VA
Primary Winding(s)
Dual
Secondary Winding(s)
Dual, Center Tap
Series Output Voltage @ Current
24 VAC @ 1A
Parallel Output Voltage @ Current
12 VAC @ 2A
Mounting Type
Chassis Mount
Power Rating
25 VA
Product
World Series Transformers
Brand/series
World Series™/VPS Series
Configuration
Bobbin
Current, Secondary
2/1 A
Dimensions
2-13/16"W×2-5/16"H×1-15/16"D
Frequency
50/60 Hz
Mounting Hole Centers
2.375 "
Number Of Outlets
2
Phase
1
Power, Rating
25 VA
Standards
UL, CSA, VDE
Temperature, Operating
+30 °C
Termination
Quick-Connect
Voltage, Primary
115/230 VAC
Voltage, Secondary
12/24 VAC
Weight
1.25 lbs.
Primary Voltage Rating
115 V / 230 V
Secondary Voltage Rating
12 V / 24 V
Mounting Style
Foot
Height
2 5/16 in
Length
1 15/16 in
Termination Style
Quick Connect
Width
2 13/16 in
Current Rating
2A
Transformer Mounting
Chassis
External Height
2.313"
Peak Reflow Compatible (260 C)
No
Terminal Type
Solder Lug Or Quick Connect
Rohs Compliant
Yes
Secondary Voltages
2 X 12V
External Depth
1.938"
External Width
2.813"
Input Voltage
115VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
237-1274
V P S 24- 1000
Electrical Specifications (@25C)
1. Maximum Power: 25.VA
2. Secondary: Series: 24V CT@ 1.0A
3. Voltage Regulation: 25% TYP @ full load to no load
4. Temperature Rise: 30C TYP (45C MAX allowed)
5. Insulation Resistance: 100MΩ
Construction:
Dual bobbin construction with an insulated shroud, both made of a high temperature
material that exceeds UL flammability requirements.
Safety:
These units are designed with 4000VAC isolation between the primary and
secondary, and also, between each winding and the core. Since the dual bobbin
construction effectively reduces capacitance, electrostatic shielding is not required.
World Series Transformers are designed and manufactured to meet the following
agency approvals:
Agency File:
UL: File E53148, UL 506, General Purpose.
CSA: File LR 37220. C22.2 NO. 66, General Purpose.
VDE: File 18786-3390-0001, VDE/EN 60 950, (IEC950) information
A. Dimensions:
B. Mounting Hole Size: 3/16”
C. WT Lbs. : 1.25
D. Schematic Diagram:
RoHS Compliance:
products meet the requirements of 2002/95/EC, known as the RoHS initiative.
2-5/16
H
115/230V
50/60Hz
Technology Equipment.
2-13/16
W
5
6
2
1
Parallel: 12.0V @ 2.0A
As of manufacturing date February 2005, all standard
1-15/16
D
A
2
12
11
8
7
1-1/8
B
50/60Hz
115V
CONNECTION
PARALLEL
5/16
C
P O W E R T R A N S F O R M E R
CHASSIS MOUNT :
QUICK-CONNECT WORLD SERIES
2
1
6
5
3/16
T
50/60Hz
CONNECTION
Unit: In inches
230V
SERIES
2-3/8
MW
2
1
6
5
ML
-
H
6
5
2
1
MW
W
D
B
A
T
C
12
11
8
7

Related parts for VPS24-1000

VPS24-1000 Summary of contents

Page 1

... 24- 1000 Electrical Specifications (@25C) 1. Maximum Power: 25.VA 2. Secondary: Series: 24V CT@ 1.0A Parallel: 12.0V @ 2.0A 3. Voltage Regulation: 25% TYP @ full load to no load 4. Temperature Rise: 30C TYP (45C MAX allowed) 5. Insulation Resistance: 100MΩ Construction: Dual bobbin construction with an insulated shroud, both made of a high temperature material that exceeds UL flammability requirements ...

Page 2

... VPS16-8100 130 16. 8.1A VPS16-11000 175 16. 11.0A VPS20-1250 25 20. 1.25A VPS20-2200 43 20. 2.2A D VPS20-4000 80 20. 4.0A VPS20-6500 130 20. 6.5A VPS20-8800 175 20. 8.8A VPS24-1000 25 24. 1.0A VPS24-1800 43 24. 1.8A E VPS24-3300 80 24. 3.3A VPS24-5400 130 24. 5.4A VPS24-7300 175 24. 7.3A VPS28-900 25 28. 0.9A VPS28-1500 43 28. 1.5A ...

Page 3

Hi-pot tested at 4,000 VRMS. 2. ...