VPP24-830 Triad Magnetics, VPP24-830 Datasheet

TRANSF 12VAC 1.66A WORLD SERIES

VPP24-830

Manufacturer Part Number
VPP24-830
Description
TRANSF 12VAC 1.66A WORLD SERIES
Manufacturer
Triad Magnetics
Series
PC Mount: World Series™r
Type
Dual Primaryr
Datasheets

Specifications of VPP24-830

Maximum Power
20 VA
Primary Winding(s)
Dual
Secondary Winding(s)
Dual, No Center Tap
Series Output Voltage @ Current
24 VAC @ 83mA
Parallel Output Voltage @ Current
12 VAC @ 1.66A
Mounting Type
Through Hole
Power Rating
20 VA
Product
World Series Transformers
Brand/series
World Series™/VPP Series
Configuration
Bobbin
Current, Secondary
1.66/0.83 A
Dielectric Strength
4000 V (RMS)
Dimensions
2-1/4"W×1-5/8"H×1-7/8"D
Frequency
50/60 Hz
Number Of Outlets
2
Phase
1
Power, Rating
20 VA
Standards
UL, CSA, VDE
Temperature, Operating
+30 °C
Termination
Thru-Hole
Voltage, Primary
115/230 VAC
Voltage, Secondary
12/24 VAC
Weight
0.9 lbs.
Mounting Style
SMD/SMT
Height
1.625 in
Length
2.25 in
Termination Style
Solder
Width
1.875 in
Transformer Type
Power
Input Voltage
115V
Output Voltage
24V
Current Rating
1.66A
Transformer Mounting
PC Board
Secondary Current Nom
1.66A
Primary Voltages
115 / 230V
Rohs Compliant
Yes
Secondary Voltages
2 X 12V
Leaded Process Compatible
Yes
Output Current
1.66A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
10484
237-1071
VPP24–830
Electrical Specifications (@25C)
1. Maximum Power: 20.0VA
2. Input: Series: 230VAC, 50/60Hz; Parallel: 115VAC, 50/60Hz
3. Output: Series
4. Voltage Regulation: 25% TYP @ full load to no load
5. Temperature Rise: 30C TYP (45C MAX allowed)
6. Insulation Resistance: 100MΩ
7. Hipot: 4000VAC between primary to secondary and windings to core.
8. Recommended Fuse
Construction:
Dual bobbin construction with an insulated shroud, both made of a high temperature material that exceeds
U
Safety:
Since the dual bobbin construction effectively reduces capacitance, electrostatic shielding is not required.
W
Agency File:
UL: File E53148, UL 5085-1 and 3 (formerly UL 506), General Purpose.
UL: File E65390, UL 5085-1 and 3 (formerly UL1585), Class 2/3.
CSA: File LR 37220. C22.2 NO. 66, General Purpose.
TUV: File R 72072385, EN 60950, (IEC950) information Technology Equipment.
A. Dimensions:
B. PIN DIM. : 0.036 SQ
C. WT Lbs. : 0.90
D. Mounting Holes: .112 dia. x 2.
Connections
Input:
Output:
RoHS Compliance: Meets the requirements of 2002/95/EC, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’ website for
the most current version.
1
2
3
4
intended to be used independently.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
1.500
Inherently limited. Class 2 not wet, Class 3 wet.
Non-Inherently limited. Class 2.
Fuse must be used on secondary as conditions of acceptability for UL Class2/3 operation.
Primary and secondary windings are designed to be connected in series or parallel. Winding are not
L flammability requirements.
orld Series Transformers are designed and manufactured to meet the following agency approvals:
A
Series – Pin 7 to Pin 12, Jumper Pin 9 to Pin 10
1.625
Parallel – Pin 1 to Pin 6, Jumper Pin 1 to Pin 4 and Pin 3 to Pin 6
Parallel – Pin 7 to Pin 12, Jumper Pin 7 to Pin 10 and Pin 9 to Pin 12
Series – Pin 1 to Pin 6, Jumper Pin 4 to Pin 3
B
Series: Inherently Limited. No fusing required.
Parallel: Littelfuse p/n 313 2HXP, 2.0A 250V, slow blow, ¼ x 1 ¼ or,
4
:
1
: 24.0V CT@ 0.83A; Parallel
.187
C
Cooper Bussmann p/n BK/MDL-2, 2.0A 250V, ¼ x 1 ¼
3
:
.400
D
.400
E
1.875
F
22520B Temescal Canyon Road
Corona, California
92883
2
: 12.0V @ 1.66A
2.250
Units: In inches
G
1.460
H
P
P C M
O W E R
O U N T :
T
Publish Date: August 3, 2009
R A N S F O R M E R
W
O R L D
4
6
3
1
SCHEMATIC
1
3
4
6
c
S
B
F
R
E R I E S
A
US
H
10
12
R
7
9
C
G
E
12
10
D
D
9
7

Related parts for VPP24-830

Related keywords