VPP20-500 Triad Magnetics, VPP20-500 Datasheet

TRANSF 10VAC 1A WORLD SERIES

VPP20-500

Manufacturer Part Number
VPP20-500
Description
TRANSF 10VAC 1A WORLD SERIES
Manufacturer
Triad Magnetics
Series
PC Mount: World Series™r
Type
Dual Primaryr
Datasheets

Specifications of VPP20-500

Maximum Power
10 VA
Primary Winding(s)
Dual
Secondary Winding(s)
Dual, No Center Tap
Series Output Voltage @ Current
20 VAC @ 500mA
Parallel Output Voltage @ Current
10 VAC @ 1A
Mounting Type
Through Hole
Dimensions
1.38 in L x 1.88 in W x 1.56 in H
Product
World Series Transformers
Height
1.56 in
Length
1.38 in
Width
1.88 in
Transformer Type
Power
Input Voltage
115V
Output Voltage
20V
Current Rating
1A
Power Rating
10VA
Transformer Mounting
PC Board
Secondary Current Nom
1A
Primary Voltages
115 / 230V
Rohs Compliant
Yes
Secondary Voltages
2 X 10V
Output Current
1A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
10469
237-1056
VPP20–500
Electrical Specifications (@25C)
1. Maximum Power: 10.0VA
2. Input: Series: 230VAC, 50/60Hz; Parallel: 115VAC, 50/60Hz
3. Output: Series
4. Voltage Regulation: 25% TYP @ full load to no load
5. Temperature Rise: 30C TYP (45C MAX allowed)
6. Insulation Resistance: 100MΩ
7. Hipot: 4000VAC between primary to secondary and windings to core.
Construction:
Dual bobbin construction with an insulated shroud, both made of a high temperature material that exceeds
U
Safety:
Since the dual bobbin construction effectively reduces capacitance, electrostatic shielding is not required.
W
Agency File:
UL: File E53148, UL 5085-1 and 3 (formerly UL 506), General Purpose.
UL: File E65390, UL 5085-1 and 3 (formerly UL1585), Class 2/3.
CSA: File LR 37220. C22.2 NO. 66, General Purpose.
TUV: File R 72072385, EN 60950, (IEC950) information Technology Equipment.
A. Dimensions:
B. PIN DIM. : 0.036 SQ
C. WT Lbs. : 0.53
D. Mounting Holes: 0.112 dia. x 2.0
Connections
Input:
Output:
RoHS Compliance: Meets the requirements of 2002/95/EC, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’ website for
the most current version.
1
2
3
intended to be used independently.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
1.25
Inherently limited. No fusing required. Class 2 not wet, Class 3 wet.
Inherently limited. No fusing required. Class 2.
Primary and secondary windings are designed to be connected in series or parallel. Winding are not
L flammability requirements.
orld Series Transformers are designed and manufactured to meet the following agency approvals:
A
1.375
Series – Pin 7 to Pin 12, Jumper Pin 9 to Pin 10
Parallel – Pin 1 to Pin 6, Jumper Pin 1 to Pin 4 and Pin 3 to Pin 6
Parallel – Pin 7 to Pin 12, Jumper Pin 7 to Pin 10 and Pin 9 to Pin 12
Series – Pin 1 to Pin 6, Jumper Pin 4 to Pin 3
B
3
:
1
0.187
: 20.0V CT@ 0.5A; Parallel
C
0.200
D
0.400
E
1.562
22520B Temescal Canyon Road
Corona, California
92883
F
2
: 10.0V @ 1.0A
1.875
Units: In inches
G
1.140
H
P
P C M
O W E R
O U N T :
T
Publish Date: August 3, 2009
R A N S F O R M E R
W
O R L D
4
6
3
1
SCHEMATIC
1
3
4
6
c
S
B
F
R
E R I E S
A
US
H
10
12
R
7
9
C
G
E
12
10
D
D
9
7

Related parts for VPP20-500

Related keywords