791804-1 Tyco Electronics, 791804-1 Datasheet

no-image

791804-1

Manufacturer Part Number
791804-1
Description
TOOL TERMINATING MODULE 26-23AWG
Manufacturer
Tyco Electronics
Datasheet

Specifications of 791804-1

Lead Free Status / RoHS Status
Not applicable / Not applicable
E
G
D
i
All numerical values are in metric units [with U.S.
customary units in brackets]. Dimensions are in
millimeters [and inches]. Figures are not drawn to
scale.
G
D
Z
Figure 1
V
Terminating Module 791804-[ ]
V
Z

791804-1 Summary of contents

Page 1

... All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in i millimeters [and inches]. Figures are not drawn to scale. E Terminating Module 791804 Figure ...

Page 2

... Terminating Modules 791804 INTRODUCTION Terminating Modules 791804–[ ] are designed to be used with Modular Plug Dual Terminators 1320840– 856195–6. This combination terminates each modular plug listed in Figure 1 to create a cable assembly and tests it for electrical circuit continuity. Read these instructions completely before using the module ...

Page 3

... Terminating Modules 791804 Check that the two single–wire terminations on the limit switch to the left of the tester cable (viewing from the rear of the module) are firmly connected to the limit switch at the top–most and bottom–most terminals (normally–closed position). Verify that the green wire of the tester cable is connected to the terminator and to a suitable ground outlet ...

Page 4

... Terminating Modules 791804-[ ] Cylinder of Transition Shoulder of Modular Plug Point Modular Plug Button Head Cap Screw Hexagonal Anvil Figure 4 c. Place a modular plug (with the shield assembled, if applicable) on the hexagonal anvil. NOTE When the anvil is positioned properly,the front surface of the anvil is in the same vertical plane ...

Page 5

... Terminating Modules 791804 TERMINATING, TESTING, AND INSPECTING 4.1. Terminating and Testing Modular Plugs 1. Strip the cable insulation outer jacket within the dimension given in Figure 1. DO NOT strip the insulation from the individual conductors. Refer to the applicable application specification for proper stripping requirements: 114– ...

Page 6

... Terminating Modules 791804-[ ] CAUTION Failure to perform periodic inspection and cleaning can cause the module to make defective ! modular plug terminations leading to discontinuities on individual wire circuits. ORIENTATION TEST The tester checks for open conductors. 1:1 and 1:N If there are no open conductors, the tester checks for short circuits. No opens" ...

Page 7

... Terminating Modules 791804-[ ] PROBLEM 7. REPLACEMENT AND REPAIR Refer to the engineering documentation package shipped with the module for a list of recommended spare parts. The parts are customer replaceable. Order replaceable parts through your representative, or call 1–800–526–5142, or send a facsimile of your purchase order to 1–717–986–7605, or write to: CUSTOMER SERVICE (038– ...