69733 Tyco Electronics, 69733 Datasheet - Page 7

no-image

69733

Manufacturer Part Number
69733
Description
DIE PIDG STRATO 69710 18-16AWG
Manufacturer
Tyco Electronics
Datasheet

Specifications of 69733

Lead Free Status / RoHS Status
Not applicable / Not applicable
If the crimping chamber conforms to the gage
inspection, the dies may be considered dimensionally
correct and should be lubricated with a THIN coat of
any good SAE 20 motor oil. If the crimping chamber
DOES NOT conform to the gage inspection, the dies
must be returned for further evaluation and repair.
6. REPLACEMENT AND REPAIR
Customer–replaceable parts are listed in Figure 12.
A complete inventory should be stocked and
controlled to prevent lost time when replacement of
parts is necessary. Parts other than those listed
should be replaced by Tyco Electronics Corporation
to ensure quality and reliability. Order replacement
parts through your representative, or call
1–800–526–5142, or send a facsimile of your
purchase order to 717–986–7605, or write to:
Rev
Wire Barrel Crimping
Section of Dies Bottomed,
But Not Under Pressure
Insulation Barrel
Crimping Section
of Dies
Terminal and Splice Crimping Die Assemblies
CUSTOMER SERVICE (038–035)
TYCO ELECTRONICS CORPORATION
PO BOX 3608
HARRISBURG PA 17105–3608
B
Inspection of Wire Barrel Section
GO" Gage Must Pass Completely
Through Crimping Chamber
NO-GO Gage May Enter Partially,
But Must Not Pass Completely
Through Crimping Chamber
of Crimping Chamber
Gage
Element
Adjustment Spacers
in Position 3
Tyco Electronics Corporation
Figure 11
For customer repair service, call 1–800–526–5136.
7. REVISION SUMMARY
Revisions to this instruction sheet include:
Wire Barrel Crimping
Section of Dies Bottomed,
but Not Under Pressure
S Updated document to corporate requirements
S Replaced previous Paragraph 2.5 with
S Replaced previous Section 2 with Step 1 of
S Added CAUTION to Step 4 of Section 5
Section 2
Section 3
GO" Gage Must Pass Completely Through
Insulation Barrel Section of Crimping Chamber
NO-GO Gage May Enter Partially, But Must Not
Pass Completely Through Insulation Barrel Section
of Crimping Chamber
Inspection of Insulation Barrel Section
of Crimping Chamber
Adjustment Spacers
in Position 1
408-1632
Gage
Element
7