59993-1 Tyco Electronics, 59993-1 Datasheet - Page 3

TOOL DIE RG-174/316/188/179/187

59993-1

Manufacturer Part Number
59993-1
Description
TOOL DIE RG-174/316/188/179/187
Manufacturer
Tyco Electronics
Datasheet

Specifications of 59993-1

Connector Type
Coax Connectors
Crimp Handle
A28006-ND
Crimp Or Cable Size
RG/U-174, 179, 187, 188, 316
For Use With
228596-2 - CONN SOCKET STR SIZE 8 RG179,187228618-2 - CONN PIN STRAIGHT 30AU COAXIAL228618-1 - CONN PIN COAXIAL STRAIGHT GOLD
Lead Free Status / RoHS Status
Not applicable / Not applicable
Other names
A34783
Rev A
GO element must pass
completely through the
crimping chamber.
CRIMPING
CRIMPING
CHAMBER
Diameter
Contact
Ferrule
É É
É É
É É É É É É
É É
Center
Die Closure Configuration
GO
GO Element
Center Contact
W
Inspection of Crimping Chamber
Suggested Plug Gage Design
[.0370–.0373]
[.1260–.1263]
0.940–0.947
3.200–3.208
Crimping
Chamber
GO
GAGE ELEMENT DIAMETER
Figure 4
[.0399–.0400]
[.1309–.1310]
Crimping Die Assembly 59993–1
1.013–1.016
3.325–3.327
Die Closure Configuration
NO–GO element may enter
partially, but must not pass
completely through the
crimping chamber.
NO–GO
É
É
É É É
É
NO–GO Element
Ferrule
“W” Width
1.52 [.060]
Diameter
NO–GO
(Max)
any good SAE 20 motor oil. If the crimping chamber
does NOT conform to the gage inspection, refer to
Section 5 for information on obtaining evaluation and
repair.
For additional information regarding the use of a plug
gage, refer to 408–7424.
5. REPLACEMENT AND REPAIR
Customer–replaceable parts are listed in Figure 5.
A complete inventory should be stocked and
controlled to prevent lost time when replacement of
parts is necessary. Parts other than those listed
should be replaced by AMP to ensure quality and
reliability. Order replacement parts through your AMP
representative, or call 1–800–526–5142, or send a
facsimile of your purchase order to 717–986–7605, or
write to:
For customer repair service, please contact an AMP
representative at 1–800–526–5136.
6. REVISION SUMMARY
Revisions to this instruction sheet per EC
0990–0892–99 include:
CUSTOMER SERVICE (038–035)
AMP INCORPORATED
PO BOX 3608
HARRISBURG PA 17105–3608
S Updated to corporate requirements
S Added ‘RF 50–ohm and non–impedance
S Added tooling and reference document to
S Removed reference to obsolete document
S Removed reference to right–angle contacts
S Added ‘close dies according to instructions
S Replaced Steps 1, 2, and 3 in Section 3, A with
S Modified Step 1 in Paragraph 3.2
S Removed ‘connector’ part numbers, and added
S Replaced customer repair address with phone
matched’ to Section 1
Section 1
409–1983
from Section 3
packaged with tool’ to Step 3, Paragraph 3.1
Step 1 in Paragraph 3.1
die closure configurations to Figure 4
number
408–6775
3 of 4