68321-1 Tyco Electronics, 68321-1 Datasheet - Page 3

no-image

68321-1

Manufacturer Part Number
68321-1
Description
TOOL HAND ROTA-CRIMP 6-10AWG
Manufacturer
Tyco Electronics
Series
50 AMPr
Datasheet

Specifications of 68321-1

Lead Free Status / RoHS Status
Not applicable / Not applicable
For Use With/related Products
6-10 AWG Terminals
For Use With
53880-4 - CONN TERM 6-10AWG CRIMP PWR LOCK
Features
-
Tool Type
-
Lead Free Status / RoHS Status
na, Not applicable / Not applicable
5. MAINTENANCE AND INSPECTION
5.1. Daily Maintenance
It is recommended that each operator of the tool be
made aware of—and responsible for—the following
steps of daily maintenance:
5.2. Periodic Inspection
Regular inspections should be performed by quality
control personnel. A record of scheduled inspections
should remain with the tool or be supplied to
personnel responsible for the tool. Though
recommendations call for at least one inspection a
month, the inspection frequency should be based on
the amount of use, ambient working conditions,
operator training and skill, and established company
standards. These inspections should be performed in
the following sequence:
A. Visual
Rev B
Crimp Inspection
ROTA-CRIMP Crimping Tool 68321-1
Wire Strands Visible Here
Insulation Must Not Enter
Wire Barrel
1. Remove dust, moisture, and other contaminants
with a clean brush, or a soft, lint–free cloth. DO
NOT use objects that could damage the tool.
2. Make sure the proper retaining pins are in place
and secured with the proper retaining rings.
3. Make certain all pins, pivot points, and bearing
surfaces are protected with a THIN coat of any
good SAE 20 motor oil. DO NOT oil excessively.
4. When the tool is not in use, keep the handles
closed to prevent objects from becoming lodged in
the crimping dies and store the tool in a clean, dry
area.
1. Remove all lubrication and accumulated film by
immersing the tool (handles partially closed) in a
suitable commercial degreaser that will not affect
paint or plastic material.
2. Make certain all retaining pins are in place and
secured with retaining rings. If replacements are
necessary, refer to Section .
Contact Must Be Straight
in This Area
Figure 6
Wire Strands Must Not
Extend Beyond This Area
or Above Wire Barrel
Tyco Electronics Corporation
B. Handle Adjustment
The handle adjustment should be checked to ensure
that the dies are bottoming properly. The handle
adjustment feature is provided to compensate for
normal tool wear. To check handle adjustment, first
close handles until dies are bottomed, but not under
pressure. Then measure the distance between
handles as shown in Figure 8.
Adjustment is too tight if measurement exceeds 35.05
[1.38] Proceed as follows:
Adjustment is too loose if measurement is less than
28.7 [1.13]. Proceed as follows:
3. Inspect the head assembly, with special
emphasis on checking for worn, cracked, or broken
dies. If damage to any part of the head assembly is
evident, refer to Section , for information on
obtaining further evaluation and repair. Examples
of possible damaged die closure surfaces are
shown in Figure 7.
1. Turn both adjustment (ADJ) screws
counterclockwise approximately one–half to
three–quarter turn.
2. Turn, but do not remove, both lock (LOCK)
screws counterclockwise .
3. Flex tool by opening and closing the handles.
4. Tighten both lock screws.
5. Close the handles until the dies are bottomed
but not under pressure. Check the measurement
between the handles and, if necessary, repeat the
adjustment procedure.
1. Turn both lock (LOCK) screws counterclockwise
approximately one–half to three–quarter turn.
2. Turn both adjustment (ADJ) screws clockwise
approximately one–half to three–quarter turn.
Figure 7
Broken
Chipped
Pitted
408-2681
3 of 6